Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East HazeIton Avenue, Stockton, <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 <br />California 95205-6232 <br />Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />CHEVRON STATION #99840* <br />Facility Phone: <br />(209) 931-2186 <br />Date: <br />November 15, 2018 <br />Facility Address: <br />4344 E Waterloo Rd, Stockton, CA 95215 <br />CERS ID: <br />10181341 <br />Inspection Contact: <br />Theresa Rodriguez , <br />Title: <br />Assistant Manager <br />Phone: <br />0 - <br />Inspection Type: <br />ROUTINE INSPECTION - Operating Permit <br />Program: <br />2361 - UST FACILITY <br />Consent For: <br />I=1 Inspection El Photos I=1 Samples <br />Consent Given By: <br />Theresa Rodriguez, Assistant Manager <br />Service Technician Onsita Exp. Date: <br />Jarrod Cooke 04/06/2019 <br />Designated Operator: Exp. Date: <br />Elijah Pendergraft 10/14/2019 <br />Service Technician Manufacturer's Training <br />VMI, 02/23/19; FFS, 05/07/20; Veeder-Root, 04/17/20 <br />CCR = California Code of Regulations HSC = Health and Safety Code CFR = Code of Federal Regulations <br />V = Violation R = Repeat violation COS = Corrected on site during inspection <br />File Review <br />101 HSC 25284 Failed to obtain a permit to operate from the EHD including but not limited to unpaid permit fees DV DR DCOS <br />102 HSC 25284(a)(3)(A)/ <br />(B) <br />No written agreement between tank owner and tank operator to monitor the tank system oV oR DCOS <br />103 HSC 25292.2, 25299.30 Failure to submit and maintain complete and current financial responsibility documents oV DR ECOS <br />104 CCR 2711 UST operating permit application for facility and tank information not submitted or current DV DR oCOS <br />105 CCR 2632(d)(1), <br />2634(d) <br />Failed to have an approved UST monitoring plan DV (DR oCOS <br />106 CCR 2632(d)(2), <br />2634(e) <br />Failed to have an approved UST response plan DV DR oCOS <br />107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed EV DR ECOS <br />108 CCR 2637, 2638(e), <br />2643(g) <br />Failed to notify the EHD 48 hours prior to conducting testing oV oR DCOS <br />109 CCR 2637(a-d), 2712 Failed to test secondary containment, or failed to maintain test records for 36 months EV oR ECOS <br />110 CCR 2637(e), 2637(f) Failed to submit "Secondary Containment Testing Report Form" within 30 days after the test DV oR DCOS <br />111 CCR 2638(a) & (b), <br />2641(j) <br />Failed to test monitoring and leak detection equipment annually oV DR oCOS <br />112 HSC 25293 Failure to maintain UST records to enable the UPA to determine whether the UST is in compliance oV oR DCOS <br />113 CCR 2638(c), 2638(d) Failure to submit "Monitoring System Certification Form" within 30 days of completion of the test DV oR oCOS <br />114 CCR 2636(f)(3), <br />2643(c)(3) <br />No 0.1 gph annual line integrity test for pressurized piping, or within 30 days after repair oV oR oCOS <br />115 CCR 2715(a)(1)(B), <br />2715(a)(3) <br />"Designated Underground Storage Tank Operator Identification Form" not submitted within 30 days oV oR oCOS <br />116 CCR 2715 Designated operator, service tech or installer did not possess current ICC certification DV DR DCOS <br />117 CCR 2663, 2712(b)(6) Failure to comply with tank lining, recordkeeping, and inspection requirements oV ER DCOS <br />118 CCR 2715(a)(1)(A), <br />2715(a)(2) <br />Failure to submit the "Underground Storage Tank Statement of Understanding and Compliance Form" DV oR o COS <br />119 HSC 25299(a)(8), <br />25299(b)(7) <br />Documents were falsified or misrepresented DV ER oCOS <br />120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification EV oR DCOS <br />121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report oV ER DCOS <br />FA0003717 PR0231766 SC001 11/15/2018 <br />EHD 23-01 Rev. 09/22/16 Page 1 of 4 <br /> Underground Storage Tank Program OIR