UNDERGROUND TANK PLAN VIEW <br />FOR USE WHEN TANKS ARE PLACED SIDE TO SIDE <br />8" THICK, 4000 PSI. <br />FIBER REINFORCED <br />CONCRETE TANK SLAB SEE <br />SHEET G.0.2.2. FOR SPECS. <br />FOR OPW FILLS <br />OVERALL LENGTH: <br />46'-0" <br />OUTSIDE DIAMETER: <br />10'-0" <br />WEIGHT (DRY/ WET): <br />12,250/17,100 lbs <br />ACTUAL CAPACITY: <br />24,970 GALLONS <br />NOMINAL CAPACITY: <br />25,000 GALLONS <br />95% CAPACITY: <br />23,721.5 GALLONS <br />VO A: UNDERGROUND TANK SECTION DETAIL v <br />SCALE: 1/2" = l' -O" <br />® <br />NOTES: UST INSTALLATION <br />257000 <br />TANK SLAB: .67' X 13.5' X 50' = <br />O1 <br />SLOPE CONCRETE AWAY FROM ALL MANHOLES 1" RISE OVER 12" RUN. <br />OFIBER <br />REINFORCEMENT TO BE USED. PREMIX UNIFORMLY THROUGHOUT <br />DESCRIPTION <br />CONCRETE. <br />OREINFORCING <br />BARS TO BE NO LESS THAN 2" AND NO MORE THAN 4" FROM <br />Q01/18/2021 <br />SURFACE. <br />- 38.5 CU FT = 1,893.5 CF <br />CONCRETE SLAB AROUND MANHOLE WITH (4) #4 REBAR 60" IN <br />OREINFORCE <br />LENGTH. PLACE REBAR 6" FROM SIDES OF BOX. <br />O5 <br />SINGLE 1" CONDUIT TO EACH SUBMERSIBLE PUMP. PROVIDE SEAL -OFF AT <br />SUMP & BUILDING WIRING TROUGH. CONTAINS LINE VOLTAGE WIRING. ALL <br />CURVED BACKFILL ABOVE TANK: <br />CONDUIT PENETRATIONS MUST BE MADE WITH ROBROY PVC COATED CONDUIT <br />ONLY. <br />3.14 X 5.25'2 X 46' = 3,981.1 CU <br />ONE 1" STANDARD MONITORING HOMERUN CONDUIT TO EACH TANK. <br />FOR STANDARD MONITORING DEVICES, LOOP CONTAINMENT SUMP <br />O6 <br />SENSORS, PLLD, VAC SENSORS & TANK GAUGE TO TANK INTERSTITIAL <br />SENSOR LOCATION AND HOMERUN TO BLDG. PROVIDE SEAL -OFFS IN <br />5,071.5 CU FT - 3,981.1 CU FT = <br />BUILDING & PRIOR TO LEAVING HAZARDOUS AREA. ROUTE TO <br />INTRINSICALLY SAFE TROUGH IN BUILDING. CONDUITS SHALL CONTAIN <br />2 <br />ONLY LOW VOLTAGE WIRING FOR SENSORS. ALL CONDUIT PENETRATIONS <br />545.2 CU FT X 57.6 LBS/ CU FT <br />MUST BE MADE WITH ROBROY PVC COATED CONDUIT ONLY. <br />USE PEA GRAVEL CONSISTING OF NATURALLY ROUNDED AGGREGATE, MIN /" <br />GRAVEL COLUMN ABOVE DEADMEN: <br />MAX OF /" IN SIZE, FREE OF CLAY, SLAG, CINDERS, OR DEBRIS. ALL <br />O& <br />SUBSTITUTES MUST BE APPROVED BY MANUFACTURER'S & OWNER'S FIELD <br />1.5'X 14.5' X 46.0' X 2 = 2,001 <br />REPRESENTATIVE. <br />O8 <br />NOT USED. <br />O9 <br />NOT USED. <br />50 <br />PAD MINIMUM 2'-0" OFF OUTSIDE WALLS OF TANKS, AND MUST <br /><@TANK <br />>COVER <br />THE FOOTPRINT OF THE TANKS. REQUIRED TO PROVIDE FOR PROPER <br />z <br />TANK HOLD DOWN, AND TO PREVENT ACCIDENTAL DRILLING INTO TANK. <br />11 <br />CUT CORNER WHERE MEETING ASPHALT PAVING ONLY. SQUARE CORNERS <br />46.2 CU FT X 87.6 LBS/ CU FT X <br />WHERE MEETING CONCRETE. <br />U zoo 0 <br />REFER TO SITE SPECIFIC PLANS FOR ACTUAL PIPE RUNS & NUMBER OF <br />DRY WEIGHT OF TANK: <br />PRODUCT LINES (1 OR 2 PER UST SUMP). <br />z�C� <br />0 C/) co <br />TURBINE AND FILL SIDE SUMP CONFIGURATION SHOWN IS TYPICAL. FOR <br />13 <br />SPECIFIC DESIGN CRITERIA AT THESE SUMPS SEE ACCOMPANYING TANK <br />cr <br />INSTALLATION SITE PLAN & SUMP DETAIL DRAWINGS NOTED ABOVE. <br />14 <br />TANK ANCHORING, CONSULT LOCAL REGULATION; VERIFY WITH OWNER'S <br />O z o <br />REPRESENTATIVE. <br />UzOrn <br />zUUo <br />OVERFLOW PROTECTION: UST OVERFLOW COMPLIANCE IS ACHIEVED BY USE OF <br />Z N <br />W z O ^ <br />OVERFLOW PREVENTION DROP TUBE FLAPPER VALVE SET AT 95% AND IS IN <br />wQ}� <br />z <br />ACCORDANCE WITH FEDERAL AND STATE GUIDELINES FOR UST OVERFILL <br />15 <br />REQUIREMENTS. <br />t <br />Z � <br />z <br />w 00 w <br />AN OVERFILL ALARM AND ACKNOWLEDGE SWITCH TIED INTO THE VEEDER ROOT <br />U O <br />AUTOMATIC TANK GAUGE SYSTEM. THE MONITORING SYSTEM PROVIDES AN <br />z = <br />z 0- <br />AUDIBLE AND VISUAL ALARM WHEN THE TANK(S) ARE FILLED TO THE 90% <br />z <br />g <br />LEVEL. <br />XX NOTE: <br />INDICATES ITEMS FOUND ON MATERIALS LIST SHEETS M.5.3.01 & M.5.3.02 <br />3.5' DIA. I 1 8" CONCRETE <br />SUMPS SLAB AT <br />87.6 LB/CF <br />2 4' MIN. <br />COVER <br />TANK DEPTH <br />10.5' DIA. 4 1.5' GRAVEL <br />12,250 LBS COLUMN <br />�12" <br />13'-6" ol <br />.67' X 1.5' X 46.0' <br />DEADMAN <br />BUOYANCY CALCULATIONS <br />CALCULATION BASED ON SUBMERGED WEIGHT OF MATERIALS: <br />TANK WITH SPHERICAL ENDS, 10.5' O.A. DIA. (10' NOMINAL) <br />TANK LENGTH: 46' TANK DIAMETER 10'-6" <br />TRY 46'-0" DEADMAN, EACH SIDE, 18" WIDE X 8" HIGH <br />EMPTY TANK UPLIFT = 25,000 GAL <br />= 3,342 CU FT <br />7.48 GAL./CF <br />3,342 CU FT X 62.4 LBS/CF = 208,540 LBS <br />(DISPLACED WATER) <br />TANK SUMP UPLIFT = (2) 3.14 X 1.75'2 X 4' = 77 CU FT <br />77 CF X 62.4 LBS/CU FT = 4,804 LBS (DISPLACED WATER) <br />TOTAL TANK UPLIFT = 208,540 LBS + 4,804 LBS = 213,344 LBS <br />HOLD DOWN CALCULATION <br />CALC. <br />257000 <br />TANK SLAB: .67' X 13.5' X 50' = <br />452.25 CU FT <br />SCALE: NTS (TYPICAL CALCULATION ASSUMING 4' MINIMUM OVER <br />452.25 CU FT X 87.6 <br />LBS/CU FT = 39 617 LB <br />DESCRIPTION <br />20 <br />CUBED BACKFILL ABOVE TANK: <br />REV. PER SJCEHD <br />Q01/18/2021 <br />4' X 10.5' X 46' = 1,932 CU FT <br />- 38.5 CU FT = 1,893.5 CF <br />A <br />1,893.5 CU FT X 57.6 LBS/ CU FT <br />= 109,065 LBS <br />0 <br />31) <br />CURVED BACKFILL ABOVE TANK: <br />0 <br />3.14 X 5.25'2 X 46' = 3,981.1 CU <br />FT <br />10.5' X 10.5' X 46' = 5,071.5 CU <br />FT <br />5,071.5 CU FT - 3,981.1 CU FT = <br />1090.4 CU FT 545.2 CU FT <br />0 <br />2 <br />545.2 CU FT X 57.6 LBS/ CU FT <br />= 31,403 LBS <br />® <br />GRAVEL COLUMN ABOVE DEADMEN: <br />i <br />0 <br />1.5'X 14.5' X 46.0' X 2 = 2,001 <br />CU FT <br />FESS /0 <br />GHgO�� <br />2,001 CU FT X 57.6 LBS/ CU FT <br />= 115,257.6 LBS <br />N0. 36475 <br />50 <br />CONCRETE DEADMEN: <br />OFF- CAUF��� <br />i <br />z <br />.67'X 1.5'X46.0'=46.2 CU FT <br />Lu <br />13 <br />46.2 CU FT X 87.6 LBS/ CU FT X <br />(2) = 8,094 LBS <br />U zoo 0 <br />© <br />DRY WEIGHT OF TANK: <br />12,250 LBS 1 <br />z�C� <br />0 C/) co <br />TOTAL HOLD DOWN: 315,686 LBS <br />TOTAL HOLD DOWN: 315.686 LBS = 1.47 SAFETY FACTOR <br />TOTAL TANK UPLIFT: 213,344 LBS <br />BUOYANCY <br />CALC. <br />257000 <br />GAL. <br />TANK <br />SCALE: NTS (TYPICAL CALCULATION ASSUMING 4' MINIMUM OVER <br />OF GRAVEL <br />CLIENT: <br />4: bp <br />'Ad & <br />lir <br />ARCO <br />BP WEST COAST PRODUCTS, LLC <br />NO. <br />DATE <br />DESCRIPTION <br />Q04/10/2020 <br />REV. PER SJCEHD <br />Q01/18/2021 <br />BID PACKAGE <br />A <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />10 <br />11 <br />0 <br />SEAL: <br />FESS /0 <br />GHgO�� <br />N0. 36475 <br />* XP. 6-30-22 <br />ATF <br />OFF- CAUF��� <br />z <br />Lu <br />13 <br />Lu co <br />Q <br />• <br />U zoo 0 <br />Z <br />z�C� <br />0 C/) co <br />00 <br />rn <br />UOLclQ - <br />MQU <br />cc <br />cr <br />Qw <br />wz <br />c/'z}'L <br />I I w <br />O z o <br />(I II �Z <br />UzOrn <br />zUUo <br />zzp <br />Q <br />Z N <br />W z O ^ <br />ALU <br />wQ}� <br />z <br />Q -- <br />. <br />06 <br />t <br />Z � <br />z <br />w 00 w <br />Q <br />U O <br />z = <br />z 0- <br />z <br />g <br />a_ <br />DEVELOPMENT INFORMATION: <br />SITE ADDRESS: <br />ADDRESS <br />2510 S. STATE HWY 99 W. FRONTAGE ROAD <br />SAN JOAQUIN COUNTY, CA 95205 <br />DESIGNED BY: <br />CHECKED BY: <br />DRAWN BY: <br />ER <br />DATE: <br />PROJECT NO: <br />10/23/2019 <br />DRAWING TITLE: <br />TYPICAL 25,000 GALLON <br />DOUBLE WALL FIBERGLASS TANK <br />INSTALLATION DETAILS <br />(MID FILL) <br />SHEET NO: <br />M,5,3,04 <br />