Laserfiche WebLink
UNDERGROUND <br />SCALE: <br />8" THICK, 4000 PSI. <br />FIBER REINFORCED <br />CONCRETE TANK SLAB SEE <br />SHEET G.0.2.2. FOR SPECS. <br />OVERALL LENGTH: <br />37'-5" <br />OUTSIDE DIAMETER: <br />10'-0" <br />WEIGHT (DRY/ WET): <br />9,750/13,550 lbs <br />ACTUAL CAPACITY: <br />19,951 GALLONS <br />NOMINAL CAPACITY: <br />20,000 GALLONS <br />95% CAPACITY: <br />18,953 GALLONS <br />FUR IVUIJILR-JHILLLI IC IJIJ V1 'I <br />MANIFOLDED USTs USING SINGLE <br />2 HP TURBINE ON 20K TANK <br />(2022 CONFIGURATION) <br />FOR MASTER -SATELLITE ISTs ON <br />MANIFOLDED USTs USING DUAL <br />14 2 HP TURBINES ON 20K TANK <br />(2022 CONFIGURATION) <br />H FOR SINGLE IST & SINGLE UST <br />.5.3.15 (2012 CONFIGURATION) <br />VO v <br />A: UNDERGROUND TANK SECTION DETAIL <br />SCALE: 1/2" = l' -O" <br />® <br />NOTES: UST INSTALLATION <br />TOTAL TANK UPLIFT = 166,858 LBS + <br />4,799 LBS = 171,657 LBS } <br />O1 <br />SLOPE CONCRETE AWAY FROM ALL MANHOLES 1" RISE OVER 12" RUN. <br />OFIBER <br />REINFORCEMENT TO BE USED. PREMIX UNIFORMLY THROUGHOUT <br />375.36 CU FT <br />CONCRETE. <br />375.36 CU FT X 87.6 LBS/CU FT = 32 881 LB <br />BARS TO BE NO LESS THAN 2" AND NO MORE THAN 4" FROM <br />OREINFORCING <br />SURFACE. <br />BID PACKAGE <br />CONCRETE SLAB AROUND MANHOLE WITH (4) #4 REBAR 60" IN <br />OREINFORCE <br />LENGTH. PLACE REBAR 6" FROM SIDES OF BOX. <br />O5 <br />SINGLE 1" CONDUIT TO EACH SUBMERSIBLE PUMP. PROVIDE SEAL -OFF AT <br />SUMP & BUILDING WIRING TROUGH. CONTAINS LINE VOLTAGE WIRING. ALL <br />CONDUIT PENETRATIONS MUST BE MADE WITH ROBROY PVC COATED CONDUIT <br />CURVED BACKFILL ABOVE TANK: <br />ONLY. <br />0 <br />ONE 1" STANDARD MONITORING HOMERUN CONDUIT TO EACH TANK. <br />FOR STANDARD MONITORING DEVICES, LOOP CONTAINMENT SUMP <br />O6 <br />SENSORS, PLLD, VAC SENSORS & TANK GAUGE TO TANK INTERSTITIAL <br />SENSOR LOCATION AND HOMERUN TO BLDG. PROVIDE SEAL -OFFS IN <br />4,124.4 CU FT - 3,245.5 CU FT = <br />BUILDING & PRIOR TO LEAVING HAZARDOUS AREA. ROUTE TO <br />INTRINSICALLY SAFE TROUGH IN BUILDING. CONDUITS SHALL CONTAIN <br />2 <br />ONLY LOW VOLTAGE WIRING FOR SENSORS. ALL CONDUIT PENETRATIONS <br />444.5 CU FT X 57.6 LBS/ CU FT = <br />MUST BE MADE WITH ROBROY PVC COATED CONDUIT ONLY. <br />USE PEA GRAVEL CONSISTING OF NATURALLY ROUNDED AGGREGATE, MIN '/0" <br />GRAVEL COLUMN ABOVE DEADMEN: <br />MAX OF /" IN SIZE, FREE OF CLAY, SLAG, CINDERS, OR DEBRIS. ALL <br />O& <br />SUBSTITUTES MUST BE APPROVED BY MANUFACTURER'S & OWNER'S FIELD <br />CU FT <br />REPRESENTATIVE. <br />O8 <br />NOT USED. <br />O9 <br />NOT USED. <br />CONCRETE DEADMEN: <br />PAD MINIMUM 2'-0" OFF OUTSIDE WALLS OF TANKS, AND MUST <br /><@TANK <br />>COVER <br />THE FOOTPRINT OF THE TANKS. REQUIRED TO PROVIDE FOR PROPER <br />z <br />TANK HOLD DOWN, AND TO PREVENT ACCIDENTAL DRILLING INTO TANK. <br />11 <br />CUT CORNER WHERE MEETING ASPHALT PAVING ONLY. SQUARE CORNERS <br />Lu co <br />Q <br />WHERE MEETING CONCRETE. <br />DRY WEIGHT OF TANK: <br />REFER TO SITE SPECIFIC PLANS FOR ACTUAL PIPE RUNS & NUMBER OF <br />12 <br />PRODUCT LINES (1 OR 2 PER UST SUMP). <br />TOTAL HOLD DOWN: <br />TURBINE AND FILL SIDE SUMP CONFIGURATION SHOWN IS TYPICAL. FOR <br />13 <br />SPECIFIC DESIGN CRITERIA AT THESE SUMPS SEE ACCOMPANYING TANK <br />INSTALLATION SITE PLAN & SUMP DETAIL DRAWINGS NOTED ABOVE. <br />c/) Z}LL <br />TANK ANCHORING, CONSULT LOCAL REGULATION; VERIFY WITH OWNER'S <br />14 <br />REPRESENTATIVE. <br />`'zoco <br />z U U o <br />OVERFLOW PROTECTION: UST OVERFLOW COMPLIANCE IS ACHIEVED BY USE OF <br />O> <br />OVERFLOW PREVENTION DROP TUBE FLAPPER VALVE SET AT 95% AND IS IN <br />w< <br />z coz <br />ACCORDANCE WITH FEDERAL AND STATE GUIDELINES FOR UST OVERFILL <br />15 <br />REQUIREMENTS. <br />Z �t <br />w 00 w <br />AN OVERFILL ALARM AND ACKNOWLEDGE SWITCH TIED INTO THE VEEDER ROOT <br />O O <br />AUTOMATIC TANK GAUGE SYSTEM. THE MONITORING SYSTEM PROVIDES AN <br />z = <br />z 0- <br />AUDIBLE AND VISUAL ALARM WHEN THE TANK(S) ARE FILLED TO THE 90% <br />z <br />g <br />LEVEL. <br />XX NOTE: <br />INDICATES ITEMS FOUND ON MAT <br />41.5' <br />0 <br />3.5' DIA. <br />SUMPS <br />TANK <br />10.5' DIA. <br />9,750 LBS <br />0 <br />M.5.3.01 & M.5.3.02 <br />�12" <br />13'-6" <br />00 00 <br />BUOYANCY CALCULATIONS <br />8" CONCRETE SLAB AT <br />87.6 LB/CF <br />4' MIN. <br />COVER <br />DEPTH <br />1.5' GRAVEL <br />COLUMN <br />.67' X 1.5' X 36.0' <br />DEADMAN <br />CALCULATION BASED ON SUBMERGED WEIGHT OF MATERIALS: <br />TANK WITH SPHERICAL ENDS, 10.5' O.A. DIA. (10' NOMINAL) <br />TANK LENGTH: 37' 5-1/2" TANK DIAMETER 10'-6" <br />TRY 36'-0" DEADMAN, EACH SIDE, 18" WIDE X 8" HIGH <br />EMPTY TANK UPLIFT = 20,000 GAL <br />= 2,674 CU FT <br />7.48 GAL./CF <br />2,674 CU FT X 62.4 LBS/CF = 166,858 LBS (DISPLACED WATER) <br />TANK SUMP UPLIFT = (2) X 3.14 X 1.75'2 X 4' = 76.9 CU FT <br />76.9 CF X 62.4 LBS/CU FT = 4,799 <br />LBS (DISPLACED WATER) <br />TOTAL TANK UPLIFT = 166,858 LBS + <br />4,799 LBS = 171,657 LBS } <br />HOLD DOWN CALCULATION <br />BP WEST COAST PRODUCTS, LLC <br />NO. <br />TANK SLAB: .67' X 13.5' X 41.5' = <br />375.36 CU FT <br />Q04/10/2020 <br />375.36 CU FT X 87.6 LBS/CU FT = 32 881 LB <br />REV. PER SJCEHD <br />CUBED BACKFILL ABOVE TANK: <br />BID PACKAGE <br />4' X 10.5' X 37.5' = 1,575 CU FT <br />- 76.9 CU FT = 1,498.1 CF <br />1,498.1 CU FT X 57.6 LBS/ CU FT <br />= 82,291 LBS <br />0 <br />CURVED BACKFILL ABOVE TANK: <br />0 <br />3.14 X 5.25'2X 37.5' = 3,245.5 CU FT <br />10.5' X 10.5' X 37.5' = 4,124.4 CU <br />FT <br />4,124.4 CU FT - 3,245.5 CU FT = <br />888.9 CU FT= 444.5 CU FT <br />0 <br />2 <br />444.5 CU FT X 57.6 LBS/ CU FT = <br />25.603 LBS <br />® <br />GRAVEL COLUMN ABOVE DEADMEN: <br />1.5' X 14.5' X 36.0' X 2 = 1,566 <br />CU FT <br />SEAL: <br />1,566 CU FT X 57.6 LBS/ CU FT = <br />90,201 LBS <br />50 <br />CONCRETE DEADMEN: <br />ATF <br />OF- CAUF��� <br />.67' X 1.5' X 36.0' = 36.2 CU FT <br />z <br />36.2 CU FT X 87.6 LBS/ CU FT X <br />(2) = 6,342 LBS <br />Lu co <br />Q <br />© <br />DRY WEIGHT OF TANK: <br />9,750 LBS <br />TOTAL HOLD DOWN: <br />247.068 LBS <br />TOTAL HOLD DOWN: 247,068 LBS = 1.43 SAFETY FACTOR <br />TOTAL TANK UPLIFT: 171,657 LBS <br />BUOYANCY CALC. 20,000 GAL. TANK <br />SCALE: NTS (TYPICAL CALCULATION ASSUMING 4' MINIMUM OVER OF GRAVEL) <br />CLIENT: <br />4: bp <br />'Ad & <br />lir <br />ARCO <br />BP WEST COAST PRODUCTS, LLC <br />NO. <br />DATE <br />DESCRIPTION <br />Q04/10/2020 <br />REV. PER SJCEHD <br />Q01/18/2021 <br />BID PACKAGE <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />0 <br />10 <br />11 <br />SEAL: <br />FESS /0 <br />GHgO�� <br />NO. 36475 <br />* XP. 6-30-22 <br />ATF <br />OF- CAUF��� <br />z <br />Lu <br />13 <br />Lu co <br />Q <br />• <br />UQm o <br />Z <br />z~�� <br />0�co <br />mZ <br />CornQ <br />�QU <br />QLLI <br />w <br />c/) Z}LL <br />I I w <br />0 O z o <br />�z <br />`'zoco <br />z U U o <br />Z <br />O> <br />LU <br />w< <br />z coz <br />Q-- <br />C7oU <br />Z �t <br />w 00 w <br />Q <br />O O <br />z = <br />z 0- <br />z <br />g <br />a_ <br />DEVELOPMENT INFORMATION: <br />SITE ADDRESS: <br />ADDRESS <br />2510 S. STATE HWY 99 W. FRONTAGE ROAD <br />SAN JOAQUIN COUNTY, CA 95205 <br />DESIGNED BY: <br />CHECKED BY: <br />DRAWN BY: <br />ER <br />DATE: <br />PROJECT NO: <br />10/29/2019 <br />DRAWING TITLE: <br />TYPICAL 20,000 GALLON <br />DOUBLE WALL FIBERGLASS TANK <br />INSTALLATION DETAILS <br />(MID FILL) <br />SHEET NO: <br />M,5,3,05 <br />