Laserfiche WebLink
SAN J O A Q U I N Environmental Health Department <br /> —COUNTY— Time In: <br /> Time Out: <br /> i�C1FaR'' GreQl tress grows her— <br /> Underground <br /> ey—Underground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: ARCO AM/PM-BP Date: 10/11/2021 <br /> Address: 2510 S HWY 99 , STOCKTON 95205 <br /> Requestor: A&S ENGINEERING/ROBERT VELASCO,A&S ENGINEERING Telephone: (661)250-9300 <br /> Program Element: 2303-UST/PIPING INSTALLATION Request#: SR0081541 <br /> Inspection Type: 131 -UST INSTALLATION INSPECTION <br /> Onsite Service Technician: Adolf Alves ICC Service Tech/Installer Exp. Date: 12/07/2022 <br /> Manufacturer training: NOV, 03/09/22; Bravo, 01/08/24 <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> On-site and witnessed the following: <br /> 1. Primary piping soap test and primary line testing of all product,vapor recovery, and chase piping on the following USTs: <br /> -25,000 gallon <br /> - 12,000 gallon base, 10,000 gallon end. <br /> 2. Integrity testing of UDCs 1-8 double-wall. <br /> All passed. <br /> Vent piping has not been installed. Primary piping soap test and primary line testing of all vent piping on the 25,000 gallon and <br /> the 12,000 gallon base, 10,000 gallon end USTs is still needed. <br /> Product, vapor recovery,vent, and chase piping on the two 20,000 gallon LISTS has not been installed. Primary piping soap <br /> test and primary line testing of all product, vapor recovery,vent, and chase piping on the two 20,000 gallon LISTS is still <br /> needed. <br /> UDCs 9-11 have not been installed. Integrity testing of UDCs 9-11 is still needed. <br /> —Additional inspections are required. Refer to the approval letter dated July 8, 2021 for a list of inspections needed, and <br /> provide a 48-hour notice by emailing ust@sjgov.org. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead of having them <br /> sign. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Emailed to John Savidge, Contractor <br /> EH Specialist: ELIANNA FLORIDO Phone: (209)616-3050 <br /> SR0081541 SC131 10/11/2021 <br /> EHD 23-01 Rev.09/16/2020 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />