My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2624
>
1600 - Food Program
>
PR0546874
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2021 11:26:54 AM
Creation date
11/16/2021 11:23:54 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546874
PE
1614
FACILITY_ID
FA0026557
FACILITY_NAME
JUST DOUGH IT LODI DBA CRUMBL COOKIE LODI
STREET_NUMBER
2624
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95242
CURRENT_STATUS
01
SITE_LOCATION
2624 W KETTLEMAN LN STE 150
P_LOCATION
02
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SEALNAIL STRIP WITHMOUNTING FRAMESECURE TO UNIT CURBWITH (4) #10 x 12" TEKSCREWS, TYPICALMOUNTING FRAME BYUNIT MANUFACTURER.(EXTENDS ALL AROUNDPERIMENTER OF UNIT)(2) LAYERS OF 1" GYPSUMBOARD WITH JOINTSSTAGGERED FOR SOUNDCONTROL4x6 BLOCKING W/U HANGER AT EACH ENDUNIT HOLD DOWN TO BEFABRICATED FROM6" W x 16 GA. STEEL, TYPICAL OF (4)SECURE UNIT BASERAIL WITH (4) #10 x 1" TEKSCREWS, TYPICALREFER TO ACATTACHMENT DETAIL THIS SHEET26 ga. S/M COUNTER FLASHINGRIGID INSULATOINROOF SHEATHING, SEEARCHITECTURAL DRAWINGSFOR ROOFING SPECIFICATIONS12" DIA. BOLT (LENGTH AS REQUIRED)(2) PER SIDE LOCATED 8" FROM ENDS(3) PER SIDE IF GREATER THAN 4'-6"ROOF FRAMING4" MAX.SECURE TO UNIT BASE RAIL WITH(4) #10 x 12" TEK SCREWS, TYPICALINSULATED PANELSUNIT HOLD DOWNS TO BEFABRICATED FROM 6" WIDE16 GA. STEEL, TYPICAL OF (4)SECURE TO UNIT CURBWITH (4) #10 x 12" TEKSCREWS, TYPICALRETURNSUPPLYCAPABLE OF 100% ECONO. OPERATIONTO BE SUPPLIED WITH POWER EXHAUSTECONOMIZER CAPACITY SCHEDULE100% (BAROMETRIC)& UP7.5 TONS6 TONS5 TONS3-4 TONS85% (BAROMETRIC)70% (BAROMETRIC)170017001700UNIT SIZERELIEF %PERCENTAGECAPACITIESRELIEFCFM9"x30"9"x30"9"x30"RELIEFSIZEREDUCE GAS LINE SIZETO UNIT SIZE AT FINALELBOW (BY P.C.)CONDENSATE LINEWITH TRAPREFER TO PLUMBINGDRAWINGS FOR DETAILREFER TO PIPEPENETRATION DETAILSEE PLUMBINGDRAWINGSGAS TO PENETRATE THRUKNOCK-OUT WITHIN CURBELIMINATING ROOFPENETRATIONREFER TO ECONOMIZERDESCRIPTION SCHEDULEFOR REQUIREMENTSWATER ENTRAINMENTOUTSIDE AIR FILTERBAROMETRIC RELIEFSEE MANUFACTUREDCURB DETAIL THIS DRAWING1" ACOUSTICAL DUCTLINING ON RETURN ANDSUPPLY DUCTS. SEEFLOOR PLANFOR SIZES, TYPICALGREASE CONTAINERSUPPLIED WITH FANVENTED CURB EXTENSIONEXHAUST DUCT - SEE PLAN FOR SIZESEE ARCHITECTURAL DRAWINGS FORROOF CONSTRUCTIONSIMPSON ST292 TIE STRAP, OR EQUALTYPICAL AT ALL (4) SIDES12" DIAMETER BOLT @ 6'-0" O.C.,LENGTH, AS REQUIREDUPBLAST EXHAUST FANNEMA 3R DISCONNECT14" LAG BOLT, 2 EACH SIDEADDITIONAL SUPPORT, AS REQUIRED8" <br />40" <br />MINIMUM DISCHARGE LENGTH <br />MINIMUM <br />CURB HEIGHTCANT STRIP ALL AROUNDPROVIDE WEATHERPROOFTIE-IN ALL AROUND#10 S/M SCREW2 EACH SIDE, TYPCIAL12" DIAMETER BOLT AT 6'-0" O.C.,LENGTH, AS REQUIREDMINIMUM 4x6 WITHU-HANGER, EACH ENDCANT STRIP ALL AROUNDPROVIDE WEATHERPROOFTIE-IN ALL AROUNDMAKE-UP AIR UNIT14" DIAMETER LAGBOLTS @ 24" O.C.CURB CONSTRUCTEDOF 18 GA. GALVANIZEDSTEEL, TYPICALSEE PLAN FOR DUCT SIZESEE ATTACHMENT DETAIL,THIS DRAWING#10 WIRE FROM STRUCTUREINSTALL DRAWBANDS ON BOTHENDS OF FLEX DUCT, TYPICAL24" x 24" DROP-INMODULE CEILING DIFFUSER#7 x 12" S/M SCREWS, (4) REQUIREDMINIMUM 3x DUCT DIA.INSTALL WITH REGISTERBOX WHERE CONDITIONSPREVENT 3x DUXT DIA.INSTALL TAPERWHEN REQUIRED#10 x 12" S/MSREW, TYPICALSUSPENDED GRID CEILINGSYSTEM, SEE ARCHITECTURALDRAWINGS FOR SPECIFICATION26 GA. GALVANIZED S/M CLIPROOFROOF STRUCTUREHANGER WIRE ORBLOCKING AS REQUIREDGRILLEFINISHED CEILINGTAPPED FLEXIBLECONNECTIONBACKDRAFT DAMPER4" C E.A. DUCT26 GA. GALV.EXHAUST HOOD1/4" MESH G.I. SCREENUCEF45°6"4"6"4"2"STORM COLLARWITH DRAW BAND ON TOPFLASHINGBLOCKING1" x 18" RING CLAMPS ANDSUPPORT BRACKETSSECURE WITH 14" DIA. x 2"LAG SCREWSBRIEDERT TYPE"B" FLUE CAPROOF COVERING, TYPICALSEE ARCHITECTURAL DRAWINGSROOF STRUCTURE, TYPICALSEE ARCHTIECTURAL DRAWINGSDOUBLE WALL FLUE1" AIR SPACEWOOD STRUCTURAL MEMBERTHREADED INSERTTHREADED STUDTRIM EXCESS WIRE ROPEEXPOSED DUCTWIRE ROPEWIRE ROPESELF LOCKING, ADJUSTABLE GRIPREFER TO PLANS FORMOUNTING ANGLESUPPLY GRILLENOTES:1. INSTALL PER MANUFACTURER'S RECOMMENDATIONS FOR LOADING2.APPROVED MANUFACTURER IS GRIPPLE. WWW.GRIPPLE.COM3. WIRE ROPE AND THREADED STUD SHALL BE PROVIDED AS ONE ASSEMBLYM-3.07FLEX DUCT MOUNTING4UPBLAST KITCHEN EXHAUST FANSCALE:1-1/2" = 1'-0"1HVAC UNIT CURB5UPBLAST EXHAUST FAN2AC UNIT ATTACHMENT6CEILING MOUNTED EXHAUST FAN3AC UNIT CONNECTIONSSCALE:1-1/2" = 1'-0"SCALE:1-1/2" = 1'-0"SCALE:1-1/2" = 1'-0"SCALE:1-1/2" = 1'-0"SCALE:1-1/2" = 1'-0"SCALE:1-1/2" = 1'-0"8DUCT SUPPORT - WIRE HANGINGSCALE:1-1/2" = 1'-0"9WATER HEATER FLUESCALE:1-1/2" = 1'-0"OFSHEETSTAF9/15/202020-162DRAWNAS SHOWNSCALEDATECHECKEDJOB NO.SHEETREVISIONSBYSLWPROJECT : <br />CLIENT : <br />LOCATION : <br />CRUMBL COOKIES <br />2624 W. KETTLEMAN LANE, #150 <br />LODI, CA 95242 <br />THEODORE J. BRANDVOLD, ARCHITECT <br />616 14th STREET, MODESTO, CA 95354 <br />PH (209) 571-8158 FAX (209) 571-8160 <br />JUST DOUGH IT RENEWAL DATEC-25449JATEO <br />DEONCE <br />SERLI <br />D <br />THEST <br />OFORNVTARCHITEC.BRANDLI ODACALIF6-30-21INTERIOR TENANT IMPROVEMENT <br />A.P.N.: 058-03-022
The URL can be used to link to this page
Your browser does not support the video tag.