Laserfiche WebLink
jmwells design <br />713 washington street <br />kerrville, texas 78028 <br />830.890.8808 <br />jmwellsdesign@gmail.com/ <br />jackmwells@outlook.com <br />C O P Y R I G H T 2 0 1 7 <br />B I N D I N G . . .D:\Jack\My Documents\Drawings\LEER CONSTRUCTION\JANOON Banquet Remodel\Janoon Tenant Improvement a0.dwg-- <br />A0.0 <br />18.106 <br />CoverTenant Improvement112 East Yosemite AvenueManteca, CaliforniaPHASE 2Janoon Banquet and Event HallYosemite Street Elevation <br />3/16" = 1'-0" <br />Tenant Improvement <br />112 East Yosemite Avenue <br />Manteca, California <br />PHASE 2 <br />Janoon Banquet and Event Hall <br />1 Project Site - <br />Janoon Banquet and Event Hall <br />Off-Site Parking - <br />City of Manteca, California <br />Bank of America <br />2 <br />3 <br />4 Financial Center Credit Union <br />Papa Joes BBQ <br />Retail Space <br />5 <br />6 <br />Project Data: <br /> - Lot Size 15,533.47 +/- ft² <br /> - Building Footprint <br />- Lower Level existing 13,271.00 +/- ft² <br /> - demolition (existing outdoor dining patio) 2,427.00 +/- ft² <br /> - new dining hall 2,674.00 +/- ft² <br /> - Lower Level "Proposed"13,518.00 +/- ft² <br /> - Lot coverage percentage 88% <br /> - Existing Zoning CBD "Central Business <br /> - Parking Spaces <br /> " adjacent off-site parking "48 <br /> 3 ADA <br /> "off-site" Leased, per agreement dated Sept. 20,2018 20 <br />Project Scope <br />Janoon Phase 2 Project Scope <br />Demolish existing outdoor dining patio/ corridor (approximately 2427 square <br />feet) adjacent the intersection of Yosemite and Grant avenues. Construct a new <br />enclosed dining room (approximately 2674 square feet) with private upper level <br />events deck/lounge. Convert existing storage area to a commercial kitchen <br />(“relocated” kitchen from Phase One work). And create service hall at second <br />floor by extending existing hall way. <br />A "Off-site" Parking; 130-142 N. Grant Ave. <br />Location/Vicinity Plan <br />PLAN <br />NORTH <br />13 4 <br />5666 <br />6 <br />6 <br />6 6 <br />2 <br />A <br />Project Site - <br />Janoon Banquet and Event Hall <br />Building Renovation/ Addition for: <br />Janoon Banquet and Event HallCode Analysis <br />APN # 221-020-330-000 <br />Project Address: 112 East Yosemite Avenue, Manteca, California <br />Legal Jurisdiction: Manteca, California <br />Hours of Operation:Restaurant hours - 11:00 am to 2:00 am <br /> Upper Deck hours -6:00 pm to 2:00 am <br />Construction Type: Type VB <br />Sprinkler System: Sprinkled, General Contractor shall employ the services of a <br />sprinkler contractor to design and install sprinkler system for new work at Phase 2 Dining <br />Room, sprinkler system existing at kitchen/ storage areas. <br />Building Occupancy: A2 Dining/ Kitchen and S2 Low hazard storage <br />Number of Stories 2 <br />Occupancy Load: (per CBC table 1004.1.2) Phase 2 <br /> 337 occupants <br />Building Codes: 2016 CALIFORNIA BUILDING CODE, 2016 CALIFORNIA <br />MECHANICAL CODE, 2016 CALIFORNIA ELECTRICAL CODE, 2016 CALIFORNIA PLUMBING <br />CODE, 2016 CALIFORNIA FIRE CODE, 2016 CALIFORNIA ENERGY CODE, Accessibility <br />Guidelines, (CAC - Title 24)(ADA) American with Disabilities Act of 1990 <br />Site Data <br />1. All improvements shall comply with the City of Manteca Standards Plans and <br />Specifications. Improvements plans shall be submitted to the City Engineer for approval. An <br />encroachment permit is required for all disturbance within the public right-of-way or to <br />public facilities. This includes closures or encroachment for purposes of construction. <br />2. During all construction phases, Developer shall comply with City Laws regarding dust <br />control. Developer shall also comply with San Joanquin Valley Unified Air Pollution Control <br />District Regulation VIII (Fugitive Dust Prohibitions) in an effort to reduce the amount of fine <br />particulate matter (PM10) entrained into the ambient air from man made sources. <br />3. Application shall include a grease trap, in accordance with City Standards, on the <br />private portion of this project's grey water/ sanitary sewer system. The grease trap shall be <br />located within project's property limits. <br />4. No portion of the building shall, or attached structures, may cross into the City's <br />fight-of-way. <br />Engineering Conditions of Approval <br />Drawing Index <br />Site/ Code <br />A0.0 Cover <br />A0.1 Site Plan <br />A0.2 Occupancy Diagrams <br />A0.3 Egress/ Exiting Diagrams <br />A0.3a ADA Path of Travel <br />Demolition <br />A1.0 Existing Condition/ Demolition - Lower Level <br />A1.1 Existing Condition/ Demolition - Upper Level <br />A1.2 Existing Condition/ Demolition - Exterior Elevations <br />Architectural <br />A2.0 Floor Plan - Lower Level <br />A2.1 Floor Plan - Upper Level <br />A2.2 Roof Plan <br />A2.2a Roof Details/ Specifications <br />A2.3 Enlarged Plan - Kitchen <br />A2.4 Enlarged Plan - Upper Level Toilet Rooms <br />A2.5 Schedules <br />A2.6 Enlarged Plan - Lower Level Toilet Rooms <br />A3.0 Exterior Elevations <br />A3.1 Canopy Plan/ Elevations <br />A3.1a Canopy Plan/ Elevations <br />A4.0 Building Sections <br />A4.1 Building Sections <br />A4.2 Wall Sections <br />A5.0a Reflected Ceiling Plan - Lower Level <br />A5.0b Reflected Ceiling Plan - Upper Level <br />A5.1 Reflected Ceiling Plan - Dining Hall <br />A5.2 Reflected Ceiling Plan - Kitchen <br />CG1.1 California Green Code Mandatory Requirements Sheet 1 <br />CG1.2 California Green Code Mandatory Requirements Sheet 2 <br />CG1.3 California Green Code Mandatory Requirements Sheet 3 <br />Structural <br />S1.0 Structural Specifications <br />s1.1 Special Inspections <br />S2.0 Foundation Plan <br />S2.0A Slab plan <br />S2.1 Framing Plan - Main Frames <br />S2.2 Framing Plan - Secondary <br />S2.3 Framing Plan - Roof <br />S3.0 Details <br />S3.1 Sections <br />S3.2 Sections <br />S3.3 Sections <br />S3.4 Sections <br />S3.5 Sections <br />MEP <br />Mechcanical <br />m1.0 Existing Conditions - Mechanical Schematic <br />m2.0 Mechanical Schematics <br />m2.1 Mechanical Schematics - Fire Wrap <br />m2.2 Mechanical Schematics - Duct Wrap/ Access Door <br />m3.0 "CAPTIVAIRE" - Kitchen Hood Drawings <br />m3.1 "CAPTIVAIRE" - Kitchen Hood Drawings <br />m3.2 "CAPTIVAIRE" - Kitchen Hood Drawings <br />m3.3 "CAPTIVAIRE" - Kitchen Hood Drawings <br />m3.4 "CAPTIVAIRE" - Kitchen Hood Drawings <br />Electrical <br />e0.0 Site - Photometrics <br />e1.0a Electrical Schematic - Lighting <br />e1.0b Electrical Schematic - Lighting <br />e2.0a Electrical Schematic - Power <br />e2.0b Electrical Schematic - Power <br />e3.0 Electrical Schematic - Control <br />Plumbing <br />p1.0 Plumbing Schematic <br /> - Existing Conditions <br />p2.0 Plumbing Schematic - <br /> Proposed Layout <br />Title 24 Tailored Energy Services <br /> (8 1/2x 11, attached) <br />EN-1 Energy Calculations <br />EN-2 Energy Calculations <br />EN-3 Energy Calculations <br />Consultants: <br />OWNER <br />HARJINDER and RAVINDER BHADE <br />10020 ROSEVIEW DRIVE <br />SAN JOSE, CALIFORNIA 95127 <br />408.410.4011 <br />510.556.6266 <br />DESIGNER <br />jmwells <br />713 WASHINGTON ST <br />KERRVILLE, TEXAS 78028 <br />830.890.8808 <br />design <br />MECHANICAL <br />ATLANTIC HVAC, INC. <br />9320 TREBBIANO CIRCLE <br />ELK GROVE, CALIFORNIA 95624 <br />STRUCTURAL <br />PACWEST CONSULTANTS, INC. <br />5401 NORTH HICKMAN ROAD <br />DENAIR, CALIFORNIA 95316 <br />209.485.8620 <br />PLUMBINGELECTRICAL <br />E.J. PLUMBING <br />1113 FISH DRIVE <br />MODESTO, CALIFORNIA 95351 <br />209.589.5742 <br />HADEN ELECTRIC <br />3918 JUNIPER DRIVE <br />DENAIR, CALIFORNIA 95316 <br />209.261.0927 <br />CONTRACTORDEVELOPER <br />LEER CORPORATION <br />1854 MAIN STREET <br />ESCALON , CALIFORNIA 95320 <br />off 209.691.4222 <br />cell 209.495.0743 <br />INDERJIT S. TOOR <br />CONTRACTORS, INC. <br />2309 TENAYN DRIVE <br />MODESTO , CALIFORNIA 95354 <br />off 209.652.5633 <br />1. SITE ADDRESS BUILDING NUMBERS SHALL BE PLAINLY VISIBLE FROM THE STREET FRONTING <br />THE PROPERTY. BUILDING NUMBERS SHALL CONTRAST WITH THEIR BACKGROUNG AND BE <br />MINIMUM 12 INCHES IN HEIGHT. <br /> a. BUILDING NUMBERS FOR THE REAR BUILDINGS SHALL BE VISIBLE FROM MAIN DRIVE AISLE. <br />BUILDING NUMBERS TO BE PLACED IN A UNIFORM POSITION ON THE BUILDING FACADE <br /> b. MAN DOOR ON 'THE REAR OF BUILDING SHALL SHALL HAVE 4" ADDRESS. <br />2. ALL ABOVE GROUND GAS METERS, REGULATORS, AND PIPING, EXPOSED TO VEHICULAR <br />DAMAGE SHALL BE PROTECTED IN APPROVED MANNER. <br />3. FIRE SUPPRESSION SYSTEMS: ALL BUILDINGS MUST BE PROTECTED BY AN APPROVED <br />MONITORED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE TO NFPA 13, CFRC, CBC, <br />AND MANTECA MUNICIPAL CODE SECTION 15.24 <br />4. FIRE SUPPRESSION APPROVAL: PLANS AND SPECIFICATIONS FOR FIRE SUPPRESSION <br />SYSTEMS SHALL BE SUBMITTED FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION. IF <br />WORK DIFFERS FROM APPROVED PLANS, A SET OF "AS BUILT" SHALL BE SUBMITTED TO THE FIRE <br />DEPARTMENT PRIOR TO FINAL INSPECTION. <br />5. INSPECTIONS: FIRE PROTECTED SYSTEMS (FIRE HYDRANT, WATER MAINS, Etc.) SHALL BE <br />INSTALLED, TESTED AND APPROVED BY CITY PRIOR TO THE ISSUANCE OF ANY BUILDING <br />PERMITS. THE FIRE DEPARTMENT SHALL WITNESS ALL SYSTEMS AND ACCEPTANCE TEST. <br />PROVIDE 24 HOUR NOTICE PRIOR TO ANY SYSTEM OR ACCEPTANCE TEST. 209-456-8340. <br />6. A FIRE DEPARTMENT APPROVED "KEY LOCK BOX" SHALL BE PROPERLY INSTALLED NEAR THE <br />MAIN ENTRANCE. A 3200 SERIES LOCK BOX CAN BE ORDERED ONLINE DIRECTLY FROM <br />KNOXBOX.COM. CONTACT FIRE MARSHALL AT FIREMARSHAL@MANTECAFIRE.ORG FOR <br />ADDITION INFORMATION. <br />7. TRASH ENCLOSURES/ DUMPSTERS SHALL NOT BE INSTALLED WITHIN 5 FEET OF ANY <br />COMBUSTIBLE WALLS, OPENINGS, OR COMBUSTIBLE ROOF EAVES, UNLESS PROTECTED BY <br />AUTOMATIC FIRE SPRINKLERS. <br />8. AUTHORITY HAVING JURISDICTION: <br /> CITY OF MANTECA FIRE DEPARTMENT <br /> OFFICE OF THE FIRE MARSHAL <br /> FIRE MARSHALL LANTZ REY <br /> 1154 SOUTH UNION ROAD, MANTECA, CALIFORNIA 95337 <br /> FIREMARSHAL@MANTECAFIRE.ORG <br />THIS PROJECT SHALL CONFORM TO THE FOLLOWING CODES: <br />2016 CALIFORNIA BUILDING CODE <br />2016 CALIFORNIA PLUMBING CODE <br />2016 CALIFORNIA MECHANICAL CODE <br />2016 CALIFORNIA ELECTRICAL CODE <br />2016 CALIFORNIA ENERGY CODE <br />2016 CALIFORNIA FIRE CODE <br />1. THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS FOR <br />SITE AND BUILDING PRIOR PROCEEDING WITH THE SAID WORK. <br />2. CONFLICTS IN THE CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION <br />OF THE DESIGN PROFESSIONAL AND/OR OWNER'S REPRESENTATIVE. <br />3. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER <br />SCALED DIMENSIONS. <br />4. THE DRAWINGS INDICATE LOCATION, DIMENSIONS , AND TYPICAL CONSTRUCTION <br />DETAILS. THE DRAWINGS DO NOT ILLUSTRATES EVERY DETAILS. WORK NOT PARTICULARLY <br />DETAILED, SHALL BE OF CONSTRUCTION SIMILAR TO PARTS THAT ARE DETAILED. <br />5. DO NOT SUBSTITUTE, REVISE, OR CHANGE THE WORK WITHOUT THE WRITTEN CONSENT OF <br />THE DESIGN PROFESSIONAL. <br />6. ALL DIMENSIONS, WHEN SHOWN IN THE DESIGN DOCUMENTS, ARE TO FACE OF STUDS <br />UNLESS NOTED OTHERWISE. <br />7. NOTES ARE AN AID TO THE CONTRACTOR IN UNDERSTANDING THE WORK AND SHOULD <br />NOT BE CONSTRUED AS BEING COMPLETE IN EVERY DETAIL. IT IS THE RESPONSIBILITY OF THE <br />CONTRACTOR TO BECOME THOROUGHLY FAMILIAR WITH THE WORK, AND REPORT ALL <br />DISCREPANCIES BETWEEN THE CONSTRUCTION DOCUMENTS AND ACTUAL CONDITIONS TO <br />THE DESIGN PROFESSIONALS. <br />General Notes: <br />Fire Department Notes: <br />5. Prior to final inspection, City inspectors shall determine if curb, gutter or sidewalk <br />damage occurred as a result of the project's construction. Damaged infrastructure shall be <br />replaced by the applicant/ contractor. Sidewalk installed with this project shall be six inches <br />(6") thick <br />Corrections/comments: <br />1.All conditions of approval for this project (MPM-18-89) shall be written by the project developer on <br />all building permit plan check sets submitted for review and Approval. <br />2.An indenture shall be recorded in the office of the County Recorder designating 19 additional <br />off-street parking spaces located not farther than 300 feet measured along the shortest available route of <br />pedestrian access from the site of any such participating use and the use to be served, with legal <br />descriptions of all sites involved, nd certifying that the off-street parking facility shall not be used for any <br />other purpose unless the restriction is removed by resolution of the City Council. An attested copy of <br />the recorded indenture shall be filed with the Public Works Director. The City-owned parking lot located at <br />123 S. Grant Ave. shall not count towards these 19 off-street parking spaces. The indenture must be <br />submitted with the building permit. <br />3.Provide correspondence from the City's Administration Office approving and authorizing the plans <br />to slurry seal and re-strip the entire parking lot and providing ADA access from the City-owned parking lot <br />at 123 S. Grant Ave ... <br />5401 N. Hickman Rd., Denair, Ca. 95316 <br />(209) 485-8620 <br />San Joaquin County <br />Environmental Health Department <br />1868 E. Hazelton Ave. <br />Stockton, CA 95205 <br />(209) 468-3420 <br /> <br />APPROVED WITH CONDITIONS <br /> <br />For conditions, please see approval letter dated: <br /> <br />Approved by:_______________________Date:_______________ <br />6-12-20 <br />Jun 12, 2020 Gehane Fahmy