My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VERNALIS
>
9000
>
2800 - Aboveground Petroleum Storage Program
>
PR0541548
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2022 11:41:27 AM
Creation date
12/1/2021 9:07:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0541548
PE
2832
FACILITY_ID
FA0009758
FACILITY_NAME
SFPUC Tesla Treatment Facility
STREET_NUMBER
9000
Direction
W
STREET_NAME
VERNALIS
STREET_TYPE
Rd
City
Tracy
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
9000 W Vernalis Rd
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN ,dDAQ U I <br /> N Environmental Health Department <br /> C0uT IV <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SFPUC Tesla Treatment Facility 9000 W Vernalis Rd, Tracy November 23, 2021 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 619 CFR 112.7(e), 112.8(c)(6) Failure to keep written records of procedures, inspections, and tests for at least three <br /> years. <br /> OBSERVATION: The facility failed to keep written procedures and records of inspections and tests, including <br /> integrity tests,for at least three years. Copies of inspection and testing records for the following were not found on <br /> site during the inspection: <br /> •Generator Tank#2-October 2020 monthly inspections <br /> • Day Tank#1 -January 2019 monthly inspections <br /> •Annual inspections for all tanks-year 2020 <br /> •Annual testing for the Simplex and Veeder Root-last 3 years <br /> REGULATION GUIDANCE: 112.7(e), Conduct inspections and tests required by this part in accordance with written <br /> procedures that you or the certifying engineer develop for the facility.You must keep these written procedures and a <br /> record of the inspections and tests, signed by the appropriate supervisor or inspector,with the SPCC Plan for a <br /> period of three years. Records of inspections and tests kept under usual and customary business practices will <br /> suffice for purposes of this paragraph. <br /> 112.8(c)(6)Test or inspect each aboveground container for integrity on a regular schedule and whenever you make <br /> material repairs.You must determine, in accordance with industry standards,the appropriate qualifications for <br /> personnel performing tests and inspections,the frequency and type of testing and inspections,which take into <br /> account container size, configuration, and design (such as containers that are: shop-built,field-erected, <br /> skid-mounted, elevated, equipped with a liner, double-walled, or partially buried). Examples of these integrity tests <br /> include, but are not limited to: visual inspection, hydrostatic testing, radiographic testing, ultrasonic testing, acoustic <br /> emissions testing, or other systems of non-destructive testing.You must keep comparison records, and you must <br /> also inspect the container's supports and foundations. In addition, you must frequently inspect the outside of the <br /> container for signs of deterioration, discharges, or accumulation of oil inside diked areas. Records of inspections <br /> and tests kept under usual and customary business practices satisfy the recordkeeping requirements of this <br /> paragraph. <br /> CORRECTIVE ACTION: Inspections and tests must be conducted in accordance with the written procedures <br /> developed in the Spill Prevention, Control, and Countermeasure(SPCC) Plan. Records of these inspections and <br /> tests must be signed by the appropriate supervisor or inspector and kept on-site with the SPCC Plan for three years. <br /> Immediately locate a copy of all inspection and testing records for the last three years, maintain them on-site, and <br /> submit copies to the EHD. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator on the day of inspection. A complete report was <br /> finished on 11/24/2021 and replaces the initial checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving the complete inspection report. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br /> of having them sign. <br /> FA0009758 PR0541548 SCO01 11/23/2021 <br /> EHD 28-01 Rev.9/16/2020 Page 5 of 6 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.