GREASE INTERCEPTOR SIZING CALCULATION PLUMBING INCA APPENDIX A CALCULATION ULATION PLUM o INCA KEY NOTES <br /> Ol $P.O.C. CONNECT (N) 4" GW TO (E) 4" GW 4 EXTEND AS INDICATED.O <br /> FIXTURES NO.UNITS x DFVS TOTAL DFU'S 1. PRESSURE AVAILABLE AT STREET MAIN 60.00 PSI. DOMESTIC COLD WATER SIZING CHART DOMESTIC NOT WATER SIZING CHART <br /> FLOOR DRAIN 2 x 2 = 4 2. PRESSURE LOSS DUE TO HEIGHT 4 Ft. x 0.434 . 1.74 PSI. lA $P.O.C. CONNECT (N) 3" GW TO (E) 4" GW E EXTEND AS INDICATED.O <br /> 3. PRESSURE LOSS THRU METER 3.00 PSI. F.U. F.U. <br /> TRIPLE SINK 1 x 2 = 2 PIPE SIZE PIPE SIZE <br /> DOUBLE SINK 1 x 2 = 2 4. PRESSURE LOSS DUE THRU OTHER DEVICES F.T. F.V. F.T. F.V. 2 $P.O.G. CONNECT (N) 1" CW TO (E) 1" CW EXTEND AS INDICATED. 3 <br /> (i.e. Water Softner, Backflow Preventer) . . . . . . . . 12.00 PSI. <br /> NANOOISHWLINK 1 x 2 = 2 5. TOTAL PRESSURE LOSS . . . (add lines 2 thru 4) . . 16.74 PSI. __ __ O3 PLUMBING CONTRACTOR TO FIELD VERIFY SIZE, LOCATION OF <br /> HAND SINK 2 x 2 - � ����� �' ����� 3 <br /> 6. PRESSURE REQUIRED AT HIGHEST FIXTURE . . . . . 8.00 PSI. (E) SERVICES E MAKE ANY NECESSARY ADJUSTMENTS REQUIRED <br /> PRE-RINSE SINK 1 x 2 = 2 7. PRESSURE AVAILABLE FOR FRICTION LOSS . . . . . . . 35.26 PSI. 3/4" 16 -- 3/4" 8 -- TO CARRY OUT INTENT OF DESIGN AT NO ADDITIONAL COST TO THE <br /> 1 x 2 = 2 (Subtract lines 5 & 6 from line 1) . . . . . . . . . . . . 1" 30 -- 1" 1s -- <br /> PROJECT. <br /> 8. TOTAL DEVELOPED LENGTH OF RUN 175 ft. WIVIB <br /> SERVICE SINK 1 x 3 - 3 11/4" 54 13 11/411 30 -- O SPILL DRAIN w/ SIZE AS INDICATED TO FS-I, FLOOR SINK, 4 <br /> TOTAL = 22 FRICTION LOSS CALCULATION 11/211 S5 31 11/211 46 10 w/ REQUIRED AIR GAP. REFER TO FLOOR SINK DETAIL: <br /> 1 From line 7 3( 5.26 ) PSI x 100 = 20.15 100 ft. 2" 236 116 2" 119 44 P81 ARCHITECTS <br /> PER TABLE 1014.3.6 OF THE 2019 CPC THE REQUIRED SIZE OF THE GREASE From line 8 ( 175 ) ft. <br /> INTERCEPTOR SHALL BE '150 GALLONS 11 <br /> THE SIZING CHART IS BASED ON THE SIZING CHART IS BASED ON O FD-i, FLOOR DRAIN. REFER TO DETAIL: P81 <br /> REQUIRED GREASE INTERCEPTOR SIZE TO BE INSTALLED: 150 GALLONS THE 2019 CPC APPENDIX 'A' THE 2019 CPC APPENDIX 'A' <br /> WITH A AP OF 20.15 PSI PER 100 FT WITH A AP OF 20.15 PSI PER 100 FT r�A 3O <br /> SIZE OF EXISTING GREASE INTERCEPTOR: 1,200 GALLONS w/ MAXIMUM VELOCITY OF Sft/SEC. w/ MAXIMUM VELOCITY OF 5ft/SEC. INSTALL (N) FD-1 CONNECT TO CE) GW. 57 5757 Pacific Avenue <br /> 57 <br /> ite <br /> 226 <br /> O WCO, WALL CLEAN OUT. REFER TO DETAIL: 1 Stockton, CA 95207 <br /> P8.1 <br /> ' 9 10 ' ' 9 II �� 10 <br /> 2 2000 L Street <br /> - - - - - 1 - - - - - - - -—- - 1 O FCO, FLOOR CLEAN OUT. REFER TO DETAIL: Suite <br /> e <br /> (E) STAIRWELL IF °1 (E) STAIRWELL I° P81 Sacramento, CA 95811 <br /> 111 111 O PROVIDE SOLENOID VALVE INTERLOCKED w/ FIRE <br /> .E STORAGE E STORAGE SUPPRESSION SYSTEM. <br /> 110 ••..:::•..:::•..:::•..•::.. . ... <br /> ............... .......... <br /> : . T 209.944.9110 <br /> FS-1 <br /> WH-I, WATER HEATER w/ 1 CW E 1 HW CONNECTIONS. SPILL <br /> 15 <br /> F 209.944.5711 <br /> O FULL SIZED T P RELIEF THRU WALL AT 12 AF�x. w/ ELBOW <br /> 10 <br /> 11/2" HV TURNED DOWN. REFER TO DETAIL: 10 www.wmbarchitects.com <br /> ® K K L 1;�X, ® ® K K L 1' ® PROVIDE 3"� CA d 3"� EXHAUST CONNECTIONS TO WATER P8.1 <br /> --'� �� �� �� �� �� �� ® HEATER E EXTEND t0 CONCENTRIC FLUE. <br /> 10 - "--- F -1 (E) CO <br /> $P•O.C. �`w_ ti P-I �_________J__ ___ r 10 PROVIDE 3/4" CD FROM COOLER CONDENSER AND ROUTE <br /> I I I IS I I I ' I 11�� 8 _ AS INDICATED TO FLOOR SINK W/ ELBOW TURNED DOWN <br /> STORAGE I I COLD I C' lE) Yco STORAGE I I COLD ITS �� AND REQUIRED AIRGAP. <br /> 107 I I STORAGE (EDW 107 I I STORAGE j Lff 11 PROVIDE GAS w/ SIZE AS INDICTED ON PLUMBING GAS <br /> L J 10 FCO / 8 L J 10 n / 8 ISOMETRIC ON SHEET P2.1. PROVIDE w/ GAS COCK, DIRT LEG <br /> l X .. HALLWAY /X 11 AND FLEXIBLE CONNECTION TO APPLIANCE. <br /> HALLWAY 5 \ <br /> -- - - - - - - ------- ------- - 0 - - - - -- - ::.,. .:. 1 - - - - - - - ------- -- ---------- --- - - I- - -- .::,.. _ 12 $P.O.C. CONNECT CN) 3" GTO lE) GAS E EXTEND AS INDICATED. 0 <br /> EXPANDED EXPANDED -- 13 LOUVERED DOOR, REFER TO ARCHITECTURAL DRAWINGS. <br /> KITCHEN - ?{ KITCHEN GAS GAS UP 14 5 <br /> 112 T \ / % 112 T CONCENTRIC FLUE WALLCAP. REFER TO DETAIL: <br /> P8.1 <br /> t 5 �X\ �XV 15 $P.O.C. CONNECT (N) FLOOR SINK TO EXISTING SERVICES IN <br /> . _ FLOOR <br /> < L------ <br /> Wco 4 NOT USED - Gospel Center Rescue <br /> - _ IMB_1 <br /> . ............. . <br /> Itchen <br /> FCO I/2 CW :::: :::::::::::::: LWI M <br /> 1� (E) GAS METER PLUMBING CONTRACTOR t0 VERIFY w/ PGCE <br /> THAT THE GAS METER CAN HANDLE AN ADDITIONAL GAS LOAD Remodel <br /> i � n1 <br /> GAS I) OF 1,158mloh. <br /> -----I 3 V 1 445 S San Joaquin St. <br /> ............. <br /> HS-I l HS-1 -- Stockton, CA 95203 <br /> ........... <br /> ti 1 W/ MV-1 18 $P,O.C. CONNECT CN) 2" SS TO CE) GW EXTEND AS INDICATED. O <br /> i <br /> ' :: : : : : : ::: 3" HV cD <br /> 3/4 a CW 1/2 HW <br /> FS-1 "I HY 1/2 ii CW I2 HW 1/2 CW <br /> 2 HW -!� !L I/3"-HWR I/ „ HW —— <br /> \ 4" GUJ� i \/ WCO 1/2 HW 0 0 'n 1 1/2 CW <br /> 1 1 ,W /V ' 1/2 CW I � — Q / <br /> c�i r/'11 CIW <br /> I� L 3 GW - --- - - 3" VTR 3/4u HW PLUMBING FLOOR <br /> GU1� FDI ,r}T 3 GW /2 HWR PLAN B <br /> FS-1 w/ TP-I ' 4 1/2•• CW <br /> I; SERVING-/ PREP t 5 SERVING / PREP , - <br /> a AREA 3 GW 0 2" LD. AREA /2 HW 3/4" CW <br /> 3/4 11 HW <br /> 3 1/ HWR <br /> \ ; � 4 / < <br /> :....: : (E) 4" GW 2 1" HW <br /> 2 6 4 TYPICAL KITCHEN 1/2" CW 3/4HW GAS WATER HEATER SIZING CALCULATION <br /> EQUIPMENT CALLOUT. <br /> .............. <br /> REFER TO SCHEDULE <br /> ( , , WHA-1 FIXTURES NO. UNITS x GPH TOTAL GPH <br /> ON SHEET P8.0. I I 120° WATER <br /> -- - 1-� ------ ------'-- -`- „- - <br /> - - -—-—- - - - - --- 3 - - -—- - - - - - - - - - - - - - - - - - ---- --- 3 HAND SINK 2 x 5 = 10 <br /> 0 0 (E) LAVATORY 103 1 x 5 = 5 <br /> ! I III CIII <br /> W <br /> Q 1" HW 6 TOTAL = 15 <br /> -- ---- 1/2" HWR 140` WATER <br /> � 1 � <br /> 1 TRIPLE COMPARTMENT SINK 1 x 45 = 45 <br /> DOUBLE COMPARTMENT PREP SINK 1 x 30 = 30 <br /> COM51NATION <br /> SYSTEM WASTE FOYo ER COVERED FOYER COVERED DISHWASHER 1 x 50 = 50 <br /> AND ARROWS INDICATE � 102 <br /> ENTRY DIRECTION OF HOT ; ENTRY - 1 x 24 = 24 <br /> WH-1 101 WATER FLOW, TYP. 101ZL 0 <br /> SERVICE SINK 1 x 15 = 15 <br /> 2 11 TOTAL = 194 <br /> r ——— — — — — r — — — — — — — — <br /> ':•::•::• CALCULATING THE BTU (BRITISH THERMAL UNIT) FOR GA WATER HEATER: <br /> GAS GAS GAS GAS GAS GAS 1"I— <br /> i `� ��,— ��' :•::. .:.: . n GAS G S :::' W 1 <br /> 3 FLUE 14 P 15 <br /> • ••• (E) WATER � ��� � (§) GPH x (120-60) DEGREES RISE x 11= = 9,900 BTU <br /> TtP 3" CA 194 GPH x (140-60) <br /> DEGREES RISE x 11= = 1�m.120 BTu PUBLISH HISTORY: <br /> (E) OU DOOR " > HEATER S VING <br /> :: 2 VTR (E) OUDOOR UPSTAIRS LUMBING CP- 111 (ROUNDED OFF 11) <br /> ,.:.,,..---------- _ _ No. DATE PURPOSE <br /> COVERED PORCH FIXTURES. : :: UTILITY 833 lbs/dal OF WATER - <br /> COVERE PORCH ::;:::::::..... E UTIL 2_HV___------ - <br /> _______ ( ) (E) 4 GW j:.:::r.::.::.: ( 0.15 (thermal efficiency of gas) 12.17.20 PERMIT SUBMITTAL <br /> 1 5 CLOSET 1 5 LOSET 03.12.21 PLAN CHECK#1 <br /> o $'`' ` 104 SS-1 104 THE GAS HOT WATER HEATER WITH AT LEAST A RATING OF 1�0,120 BTU <br /> SS 1 E) TOILET 3/411 CW (E) TOILET USE BRADFORD WHITE EF-60T-199E-3N INPUT = 199,000 BTU <br /> W/ O \ 103 <br /> 3/4" HW I 103 <br /> E -- - - - - - - - - - 5 - - - - - - - - - - -�- - - - - - - -� <br /> a <br /> N <br /> 0 13 Cn 0 PLUMBING GENERAL NOTES <br /> C C D 1. FOR FIX. CONNECTION SIZES TO THE VARIOUS FIXTURES, <br /> N <br /> 3" GW REFER TO THE FIX. CONNECTION SCHEDULE ON SHEET P8.0. <br /> CD <br /> 2. PER CALIFORNIA ENERGY CODE SECTION 110.3, <br /> / HOT WATER DELIVERED FROM PUBLIC USE LAVATORIES <br /> 1A SHALL BE LIMITED t0 A TEMPERATURE OF 110'F. THE <br /> L 3" G BELOW WATER HEATER THERMOSTAT SHALL NOT BE CONSIDERED <br /> GRADE. REFER A CONTROL FOR MEETING THIS PROVISION, THEREFORE <br /> Cn TO DETAILS: ALL PUBLIC USE LAVATORIES SHALL HAVE FAUCETS <br /> WITH INTERNAL TEMPERATURE LIMIT STOPS. <br /> F P8.1 <br /> o 3. SLOPE ALL SANITARY SEWER LINES WITHIN BUILDING AT 1/4"/FT. <br /> A A <br /> 4. ALL HOT WATER PIPING SHALL BE COPPER. 1/2" THRU 3/4" REQUIRES <br /> i I V INSULATION. P AND LARGER REQUIRES 11/2" INSULATION. <br /> Q I <br /> U (E) 1,200 5. PLUMBING CONTRACTOR TO COORDINATE WITH WMB PROJECT. <br /> Q L J GALLON D MECHANICAL CONTRACTOR AND ELECTRICAL 20-042 <br /> F , GREASE � (E) GAS METER CONTRACTOR TO ELIMINATE ANY SPACE CONFLICTS. <br /> w I I INTERCEPTOR <br /> INSTALLATION OF NEW WASTE AND GREASE WASTE LINE REQUIRES <br /> L SAW CUTTING OF FLOOR <br /> z <br /> ALEXANDER SCHEFLO <br /> 12 P2.0 <br /> EA s Fye, and ASSOCIATES, Inc. <br /> Mechanical Engineers (209) 948-9761 <br /> o <br /> N 2926 Pacific Ave. Stockton, Ca. 95204 <br /> 025 <br /> 0 PLUMBING SEWER AND VENT FLOOR R PLAN PLUMBING COLD p HOT WATER FLOOR PLAN � Ex . 09- 0-22 ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN <br /> O � �F P� � CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE <br /> I ��— — �� I u= — �� qTF OHANX� O� ENGINEER AND THE SAME MAY NOT BE USED, DUPLICATED, OR <br /> SCALE: /8 —1 0 SCALE: /s 1 0 0 CA_\F DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER. <br /> © Alexander Scheflo & Assoc., Inc <br /> �j Copyright WI <br /> J_ <br /> LL <br />