TYPICAL THREADED ROD HANGER <br /> SUPPORTS, SEE HANGER SCHEDULE PE PIPE <br /> & OSHPD PRE-APPROVAL NO. A DIYIsloif of CHfvxox PHILLIPS CHEMICAL COMPANY LP <br /> OPM-0052-13. <br /> PIPE HANGER SCHEDULE <br /> • ° 6500 Series <br /> PIPE SIZE HANGER ROD BOLT DRISCOPLEX° 6500 Series <br /> SQUARE SCORIATED 1h" THRU :K 1/4" 1/4" <br /> TOP WITH VANDAL 1" THRU 11x2" �§" �8" <br /> MAY EXTEND ASA PROOF SCREW <br /> M, <br /> 2 THRu 2>� 3/8" 1/2" MDPE Gas Distribution Pipe <br /> WASTE OR VENT 3 1/E L- 2" 1/2" e TYPICAL TRANSVERSE & LONGITUDINAL p <br /> WALL BRACING PER OSHPD PRE-APPROVAL \n/ /� <br /> CHROME WALLCOVER PLAN FINISHED FLOOR _ OPM-0052-13. Dmanu manufactured to meet yourneedsin `� �' ' `� ' B <br /> & SCREW f HANGER ROD- SEE INSULATION compliance with ASTM D2513, NSF <br /> ADJUSTABLE LEVEL SCHED. FOR SIZE Gas and DOT 49 CFR 192. ARCHITECTS <br /> PLUGGED TEE G. ° CONTROL HOT WATER <br /> Selected sizes conform to CSA <br /> w/ CLEANOUT FLOOR LINE WROUGHT STEEL - - B137.4 and UPC product standards. <br /> n CLEVIS HANGER- ADJUSTABLE <br /> SEE SPECS. FOR BAND HANGER- Produced from only the highest <br /> '44 ° . MEMBRANE 5757 Pacific Avenue <br /> SEE SPECIFICATIONS TYPE SEE SPECS. FOR rated MDPE pipe material, <br /> ° FOR ADDITIONAL NOTE: TYPE �� DRISCOPLEXO 6500 Series Pipe is Suite 226 <br /> ° INFORMATION GAS & CONDENSATE ALVANIZED SHIELD manufactured from a PE 2708 and Stockton, CA 95207 <br /> a ° --- PIPING SIMILAR AT INSULATION <br /> PE 80 resin listed in PPI-TR4. <br /> BALANCE OF PIPINGsC :3 CAST IRON RISER 2000 L Street <br /> SAME AS CLEANOUT TO GRADE ° aDRISCOPLEX MDPE Pipe Advantages: <br /> 1/8" C.I. BEND Suite 125 <br /> PIPE SUPPORT NOTES: ✓ Durable ✓ Fatigue Free ✓ Chemical Resistant Sacramento, CA 95811 <br /> GAS PIPES: ✓ Leak Tight ✓ Impact Resistant ✓ UV Protection <br /> PIPE 1"0 OR LARGER SHALL HAVE TRANSVERSE BRACING ✓ Excellent Flow ✓ Trenchless Install ✓ Flexibility <br /> ® 14' O.C. (MAX)& LONGITUDINAL BRACING ® 20' O.C. ✓ Abrasion Resistant ✓ Bend Radius ✓ Environmental T 209.944.9110 <br /> (MAX) PIPES LESS THAN 1"0 NEED NO BRACING. DriscoPl_ MDPE F 209.944.5711 <br /> OTHER PIPES: Property Standard Typical Valuet www.wmbarchitects.com <br /> PIPE 21/2"0 OR LARGER SHALL HAVE TRANSVERSE BRACING Material Designation Code ASTM D2513 PE 2708 <br /> > > <br /> SECTION ® 16 O.C. (MAX) & LONGITUDINAL BRACING ® 32 O.C. (MAX) Cell Classification ASTM D3350 234373E;234375E <br /> „ Density[21 ASTM D1505 0.939 g/cm3(Yellow) <br /> PIPES LESS THAN 21/2 NEED NO BRACING. Melt Index[3] ASTM D1238 0.18g/10 min <br /> TYPICAL (ALL PIPES Flexural Modulus[4] ASTM D790 >90,000 psi <br /> FOR PIPES WHERE THE DISTANCE OF THE HANGER (FROM TOP Tensile Strength[3] ASTM D638 Type IV 2,800 psi <br /> OF PIPE TO BOTTOM OF SUPPORT) IS LESS THAN 12", NO SEISMIC SCG(PENT)[7] ASTM F1473 >2,000 hours <br /> RESTRAINTS REQUIRED WHEN SPECIFIC CONDITIONS ARE MET PER HDBat73'F(23°C)[3] ASTM D2837 1,250 psi <br /> 1-6 OF OSHPD PRE-APPROVAL NO. OPM-0052-13. Color;UV Stabilizer[E] ASTM D3350 Yellow;UV Stabilized <br /> RCP,Full Scale,at 32*F (O'C) ISO 13478 >123 psi(>8.5 bar) <br /> CLEANDUT CLEAHOUT <br /> This is not a product specification and does not guarantee or establish specific minimum or maximum values or manufacturing tolerance for material or tubing products to <br /> be supplied.Values obtained from tests of specimens taken from tubing Product may vary from these typical values.The RCP Properties were determined on 8"SDR 11 <br /> �/{.7�J pipWALL e. <br /> NOT TO SCALENOT TO SCALE NOT TO SCALE _�` Bulletin PP 313 I June 2014 www.performancepipe.com 2014 Chevron Phillips Chemical Company LP <br /> DETMLD[EcrAIL D[EcTAILv Performance Pipe.a division of Chevron Phillips Chemical Company LP 15085 W.Park Blvd I Suite 500 I Plano,TX 75093 I Phone:800-527-0662 1 Fax 972-599-7329 <br /> J/ J <br /> PERR)RM MCEAPE <br /> ADIYIsION Of CHEVRON PHILLIPS CNEM w COMPANY LP <br /> A CONCENTRIC VENT KIT ALLOWS VENT AND COMBUSTION- Gospel Center Rescue <br /> NOTE: AIR PIPES TO TERMINATE THROUGH A SINGLE EXIT IN A ROOF • © 6500 Series Mission Kitchen <br /> PRIOR TO SETTING FLOOR SINK, OR SIDE WALL. „ Remodel <br /> PLUMBING CONTRACTOR TO SEMCO #1100R FLASHING <br /> ONE PIPE RUNS INSIDE THE OTHER ALLOWING VENTING THROUGH TURNED IN ON CAST IRON Nominal Number 445 S San Joaquin St. <br /> COORDINATE WITH LOCAL HEALTH THE INNER PIPE AND COMBUSTION AIR TO BE DRAWN IN q <br /> DEPARTMENT TO CONFIRM EXACT THROUGH THE OUTER PIPE. VENTS 3" & LARGER ONLY. riches) (inches) 100 ft. Pallet or Footage Stockton, CA 95203 <br /> REQUIREMENTS WHETHER FLOOR SINK • •D <br /> IS TO BE FLUSH OR RAISED 1" ABOVE v2" wA 0.625 0.09 125 6.5 1,000' 30"/44"/6" 12 12,000 26 �12000FINISHED SURFACE. 1" 1TA 1.125 0.099 77 14 500' 30"/42'411" 8 4,000' 26 04,000' <br /> II *N/A-The wall thickness is minimum per D2513 and nota function of DR. <br /> SUPPORT FLASHING 1" AIR SPACE I IPS= Iron Pipe Size PLUMBING <br /> Nominal Number Number DETAILS <br /> DRAIN PIPE CONCENTRIC CAP COMBUSTION AIRd. 10 Weight Packing Coils I Pallet/Nominal Dimension l7alum per Cl (lb.)per illjoint Dimensions Pallet 1 48 ft.Sb, 192.121 100 ft (feet) Bundles Truck=for Joints Per Bundle <br /> FINIS (I..h:s) Ratio (inches) (inches) p s I) Pallet or Footage Per Truck <br /> WALL ED I EXTEND WHERE REQ'D <br /> WALLLTO CLEAR FRESH AIR •. <br /> /Width Bundle <br /> ----- - ----- - 3/4" DR 11 1.05 0.095 80 12 500' 30"/44"/10" 7 3,500' 26 91,000' <br /> _---- _- _-- - 4D11111, INTAKES ETC. <br /> ----- - PERMASEAL � ," DR 11 1.315 0.,20 80 19 500' 30"/44"/12" 6 3,000' 26 78.000' <br /> 1/2" SINK GRATE FLUE GAS WATER PROOFINGlo 11/4' DR 10 166 0.166 89 33 500' 48"/72"/7-1/2" 12 6.000' 7 42,000' <br /> 25°/'0 OPEN COMPOUND "SEMCO" CAULK TYPE 11/2" DR 11 1.9 0.,73 80 40 500' 48'775'78-1/2" 8 4,000' 7 28,000' <br /> lo COUNTER FLASHING 2" DR„ 2.375 0216 80 63 500' 52'778'7,3" 7 3.500' 7 24,500' <br /> FINISH GRADElo SLEEVE FOR CAST IRON DR 11 0.3,8 80 136 500' 70"/96"/23-3/4" 4 2,000' 6 ,2,000' <br /> lo VENTS AND THREADED 3" 3.5 40' soft bundles 50 2,000' 14 26,000' <br /> "SEMCO" SEAMLESS LEDR,,.S 0.3°' 76 3,a OR CAULK TYPE FOR500' 70"/96"/23-3/4" 4 2.000' 6 ,2.000' <br /> < EXTERIOR FLASHING #1100-8 OR ALL STEEL VENTS DR11 0409 80 225 500' 70"/93"/41" 2 1,000' 6 6,000' <br /> - OF BLDG. #1100-4 W/ 8" SKIRT 40' soft bundles 29 14 16.24°lodAND STEEL VARIABLEI 4 DR 115 45 °.391 76 217 600' 70"/93"/49-1/2" upright 1,160' 12 7200' <br /> d _,d ° 1,000' 84"/116"/49" upright 8 coils 8,000' <br /> a 4.a• PITCH BOOT <br /> DR 13.5 0.333 64 187 40' soft bundles 29 1160' 14 16,240' <br /> DR„ 0.602 80 489 40' soft bundles 13 520' 14 7,280' <br /> NOTES: I 40' soft bundles 13 14 7,280' <br /> 6•' 6.625 520' <br /> 1.) VENT TERMINALS. VENTING SYSTEMS SHALL TERMINATE NOT LESS THAN 4 FT. I DR,,.S °.576 76 47, <br /> SET SKIRT OVER ROOF FELT 500' 84"/120"/50" upright Bcoils 4.000' <br /> BELOW OR 4 FT. HORIZONTALLY FROM, AND NOT LESS THAN I IDR 13.5 0.491 64 407 40' soft bundles 13 14 7,280' <br /> 50" <br /> 1 FT. ABOVE A DOOR, AN OPENABLE WINDOW OR A GRAVITY AIR INLET I 500' softb bundles <br /> upright 8coils 4,600' <br /> SEDIMENT BUCKET DR„ 0.764 80 828 40' soft buntlles 9 360' 0 3.666' <br /> INTO A BUILDING. PER CMC SECTION 806.6 VENT PIPE - SEE 8" PD <br /> R1t5 6.625 0.75 76 796 <br /> PLANS FOR SIZE40' soft bundles 9 360' 0 3.606' <br /> R 13.5 0.639 64 690 <br /> 2.) SEPERATION FROM INLETS. VENTING SYSTEMS SHALL TERMINATE AT LEAST 3 FT. 10 DR 11 1075 0.977 80 1287 40' soft bundles 9 360' 7 2,520' <br /> ABOVE AN OUTSIDE- OR MAKEUP-AIR INLET LOCATED WITHIN 10 FT. DR 11.5 0.935 76 1237 40' soft bundles 9 360' 7 2,520' <br /> AND AT LEAST 4 FT. FROM A PROPERTY LINE EXCEPT A 12" DR 13.5 12.75 0.944 64 1507 40' bulk packs 8 320' 6 1,920' <br /> nts/layer <br /> PUBLICWAY. PER CMC SECTION 806.6.1 This product flyer is intended for reference pu rposes. It s hould not be used in place of the advice from a licensed Profess ional Engineer. Pressure <br /> Rating is based on an operating temperature of 73'F per 49 CFR 192.Pipe weights are calculated in accordance with PPI TR-7.Nominal OD and <br /> Minimum wall plus 6%is used in estimating fluid flow.Actual ID will vary.When designing components to ft the pipe ID,refer to pipe dimensions <br /> and tolerances in the applicable pipe manufacturing specification.-These wall thicknesses are minimum per D2513 and not a function of DR. <br /> Bulletin PP 313 I June 2014 www.performancepipe.com m 2014 Chevron Phillips Chemical Company LP <br /> Performance Pipe,a division of Chevron Phillips Chemical Company LP 1 5085 W.Park Blvd I Suite 500 1 Plano,TX 75093 1 Phone:800-527-0662 1 Fax:972-599-7329 <br /> FLOOR SOAK a C;0HCENTMC; FLUE WENT THRU o UNDERGROUND GAS PUBLISH HISTORY: <br /> p e NOT TO SCALE NOT TO SCALE e NOT TO SCALE D D NOT TO SCALE <br /> DETLUL DETML R&DIF DETML POP[ SPIECIMCA"flONS N° DATE PURPOSE <br /> HOT WATER TO SYSTEM FLOW SENSER 12.17.20 PERMIT SUBMITTAL <br /> L 03.12.21 PLAN CHECK#1 <br /> o (EN) MATERIAL TO MATCH REFER TO GAS PIPING FINISHED FLOOR <br /> GAS PIPING MANDATORY MEASURES REFER TOHEIGHT MANDATORY MEASURES MAKEUPCOLD THIS SHEET AND GAS PIPE <br /> ARCHITECTURAL SPECIFICATION FOR ADDITIONALT m a ° 4 -. 7 <br /> BURIED MEDIUM PRESSURE GAS PIPING SHALL BE PROTECTED FROM DWG'S FOR FURTHER INFORMATION. GAS LINE HOT WATER RETURN ° a e.° a . <br /> E CORROSION AS REQUIRED BY CHAPTER 12 AND SHALL HAVE A MINIMUM EARTH <br /> °. 4 a ° <br /> COVER OF EIGHTEEN (16) INCHES. SUCH PIPING SHALL BE COVERED WITH AT INFORMATION D °°' ., a -° <br /> BACKFILL w/ SOIL THAT <br /> LEASTSIX 61 INCHES OF HAND PLACED SELECTED BACKFILL DEVOID OF WAS REMOVED FROM fn <br /> N GAS FIRED <br /> OR WRAPPING. <br /> MATERIALS,OR OTHER MATTER THAT MAY DAMAGE THE PIPE DIGGING OF TRENCH t � n :, °�.� '° ' °� .a <br /> WATER HEATER t EXPANSION TANK. ANCHOR WATERPROOF < <br /> TO WALL W 1 1" x 16 G.A. MEMBRANE FLASH <br /> N CCAS PIPING SUPPLYING MORE THAN ONE (1)BUILDING= ON ANY ONE (1) � A � GAS COCK � / ( )1 LEAD INTO ° ° ° ° ° <br /> O PREMISES SHALL BE EQUIPPED WITH SEPARATE SHUTOFF VALVES TO EACH D STRAPS W/ (2) /4 D x 2 LAG .a : :° d ° <br /> N BUILDING, 50 ARRANGED THAT THE GAS SUPPLY CAN BE TURNED ON OR OFF Z fn BOLTS. CLAMPING COLLAR � ° . 4. ° <br /> TO ANY INDIVIDUAL OR SEPARATE BUILDING. SUCH SHUTOFF VALVE SHALL BE d °. ° °" , ° <br /> LOCATED OUTSIDE THE BUILDING IT SUPPLIES AND SHALL BE READILY <br /> PUMP, HWCP-1 <br /> ACCESSIBLE AT ALL TIMES. oo <br /> THIS INSPECTION SHALL BE MADE AFTER ALL PIPING AUTHORIZED BY THE DIRT LEG I 1/2" HOSE BIBS I CLAMPING COLLAR <br /> PERMIT HAS BEEN INSTALLED AND AFTER ALL PORTIONS THEREOF WHICH ARE SPILL FULL SIZE TEMP. °° °° TP-1. WATERLESS <br /> TO BE COVERED OR CONCEALED ARE SO CONCEALED AND BEFORE ANY : : :: ;: ::: ::::::.: ::: - HOT WATER CIRCULATION TRAP PRIMER. <br /> 0 FIXTURES, APPLIANCE,OR SHUTOFF VALVE HAS BEEN ATTACHED THERETO. & PRESSURE„RELIEF TO PUMP CONTROL PANEL <br /> THIS INSPECTION SHALL INCLUDE AN AIR,CO2 OR NITROGEN PRESSURE TEST, EXTERIOR 12 A.F.G. W/ <br /> o AT WHICH TIME THE GAS PIPING SHALL STAND A PRESSURE OF NOT LESS THAN ELBOW TURNED DOWN <br /> 00 TEN (1)POUNDS PER SQUARE INCH (66.9 kPa)GAUGE PRESSURE, OR AT THE <br /> DISCRETION OF THE ADMINISTRATIVE AUTHORITY,THE PIPING AND VALVES MAY TEMPERATURE SENSER <br /> �o BE TESTED AT A PRESSURE OF AT LEAST SIX (6) INCHES OF MERCURY, UNDISTURBED SOIL GAS FIRED WATER HEATER <br /> El <br /> MEASURED WITH A MANOMETER OF SLOPE GAUGE. TEST PRESSURE SHALL BE GAS PIPING W/ TRACE <br /> / G M 1/4"b x 3" LONG LAG SCREW <br /> Q HELD FOR A LENGTH OF TIME SATISFACTORY TO THE ADMINISTRATIVE WIRE #14 AW PER <br /> U AUTHORITY,BUT IN NO CASE FOR LESS THAN FIFTEEN (IB)MINUTES, WITH NO 25CCR 1206(d) °° ° POSITIVELY ATTACHED TO WMB PROJECT: <br /> Z PERCEPTIBLE DROP IN PRESSURE. FOR WELDED PIPING, AND FOR PIPING 3" PVC OULET BUILDING FRAME MEMBERS, <br /> Q CARRYING GAS AT PRESSURES IN EXCESS OF FOURTEEN (14) INCHES WATER BACKFILLED TRENCH 3 4" CONDENSATE � LAG SCREW TO PENETRATE <br /> v COLUMN PRESSURE,THE TEST PRESSURE SHALL NOT BE LESS THAN SIXTY (60) PROVIDE THE PROVIDE 4" LAYER OF N/ TRAP SLOPED AT REFER TO MECH. WOOD MEMBERS AT LEAST O O DRAW <br /> 20-042 <br /> w POUNDS PER SQUARE INCH AND SHALL BE CONTINUED FOR A LENGTH OF TIME TRENCHNT BOTTOM OF A MINIMUM OF 1 8" FT ONE INCH, TVP. AT & FL00� <br /> SATISFACTORY TO THE ADMINISTRATIVE AUTHORITY, BUT IN NO CASE FOR LESS FOLLOWING / / 1NOT TO SCALE <br /> THAN THIRTY (30)MINUTES. THESE TESTS SHALL BE MADE USING AIR, CO2,OR COMPACTION: TO EXTERIOR SERVICE 213 HEIGHT OF HEATER. /s DlEcrbML <br /> NITROGEN PRESSURE ONLY AND SHALL BE MADE IN THE PRESENCE OF THE SINK <br /> z ADMINISTRATIVE AUTHORITY. ALL NECESSARY APPARATUS FOR CONDUCTING LOCATION: COMPACTION: STRAP WATER HEATER TO ALEXANDER SCHEFLO <br /> TESTS SHALL BE FURNISHED BY THE PERMIT HOLDER. TEST GAUGES USED IN 1 . SIDEWALKS, PAVEMENT, 95% <br /> Q CONDUCTING TESTS SHALL COMPLY WITH SECTION 31-1 TEST GAUGES. WALL WITH 16 GA. x 3" GA. QROFESS/ ^ w <br /> o ROADWAYS 4" ELEVATED PLATFORM STRAP TO PREVENT LATERAL A. F and ASSOCIATES, Inc. r 1 <br /> 2. GRASS AND PLANTERS 85% UNDER WATER HEATER MOVEMENT. Mechanical Engineers (209) 948-9761 <br /> N 1/2" HOSE BIBS 2926 Pacific Ave. Stockton, Ca. 95204 <br /> 025 8 <br /> * Exp. 09-30-22 ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN <br /> 0 ab%8 P0 P 0HO NQHDQTOR Q A 3 P 0 P E �A7ER u u[EATER �� CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE <br /> 00O � "9r�L.FCHAN�CP p�� ENGINEER AND THE SAME MAY NOT BE USED, DUPLICATED, OR <br /> j @ 1 O pF CPA\-\F DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER. <br /> NEb%5URE5 <br /> NOT TO SCALE `J TIRENCH <br /> D E T��L NOT TO SCALE P0P0Hu D E T p 0 L NOT TO SCALE LI Alexander Scheflo & Assoc., Inc <br /> �j Copyright WI <br /> J_ <br /> L� <br />