Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> 3 Us truck&auto plaza 1 14749 N Thornton Rd, Lodi December 20, 2021 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 706 CFR 112.8(c)(2)Failed to provide and maintain adequate secondary containment for bulk storage tanks. <br /> OBSERVATION: The facility failed to provide and maintain secondary containment for bulk storage tank installations <br /> sufficient to hold the capacity of the largest container, including adequate freeboard for precipitation. The concrete <br /> building (shop)would allow a spill to escape through the doors of the building. Table 8 of the SPCC plan states that <br /> the concrete building is the secondary containment for the following containers: <br /> -150 gallon oil tank <br /> -500 gallon oil tank <br /> -Four 280 gallon oil tanks <br /> REGULATION GUIDANCE: (c)(2)Construct all bulk storage tank installations(except mobile refuelers and other <br /> non-transportation-related tank trucks)so that you provide a secondary means of containment for the entire capacity <br /> of the largest single container and sufficient freeboard to contain precipitation.You must ensure that diked areas are <br /> sufficiently impervious to contain discharged oil. Dikes, containment curbs, and pits are commonly employed for this <br /> purpose.You may also use an alternative system consisting of a drainage trench enclosure that must be arranged <br /> so that any discharge will terminate and be safely confined in a facility catchment basin or holding pond. <br /> CORRECTIVE ACTION: Immediately provide and maintain adequate secondary containment for the above listed <br /> bulk storage tanks or ensure the SPCC plan is amended to include the correct secondary containment for the above <br /> listed bulk storage containers. Submit proof of correction to the EHD. <br /> Note: Per Francisco Alila (Shop Manager)all tanks are double walled. Inspector unable to confirm the above listed <br /> tanks are double wall tanks. <br /> This is a repeat violation, Class II. <br /> FA0000482 PR0515788 SCO01 12/20/2021 <br /> EHD 28-01 Rev.12/06/2021 Page 6 of 8 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />