Laserfiche WebLink
ME# # <br /> April 19, 1995 <br /> Jeff K. Morlan, P.E. <br /> 504 Broadway <br /> Jackson, CA 95642 <br /> Re: Soil Suitability Study for MS-92-224 <br /> San Joaquin Public Health Services, Environmental Health Division has received and reviewed <br /> your study dated April 12, 1995, and has found it acceptable, subject to the following <br /> conditions: <br /> (1) Obtain a Sanitation Permit to install the engineer designed system at the time of <br /> development. <br /> (2) The trench depth shall be twenty-four (24) inches as per recommendation on the letter <br /> of April 12, 1995 from Shaw, Morlan and Associates which reads "a shallow, twenty- <br /> four (24) inch trench depth" not thirty-six (36) inches as shown on blue prints. <br /> (3) Provide Calculations to justify total dynamic head loss; {i.e.: loss per fitting, number <br /> of fittings, loss per one hundred (100) feet of pipe by diameter and flow rate, etc.} <br /> (4) Orifices on distribution pipe shall face upwards as per EPA Design Manual, not <br /> downwards as shown on blueprints. <br /> (5) The maximum length of leach lines as permitted by San Joaquin County Code is one <br /> hundred (100) feet comply, install at least three (3) lines. <br /> (6) Indicate on the blueprints the location of the en drain to divert seasonalground water <br /> flows around sewage disposal system. J/ <br /> 7 <br /> ( ) Make an appointment with San Joaquin County Public Health Services, Environmental <br /> Health Division twenty-four (24) hours prior to pressure testing the system and prior to <br /> backfilling. <br /> � y <br />