My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_1994-1995
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WAVERLY
>
6484
>
4400 - Solid Waste Program
>
PR0440004
>
CORRESPONDENCE_1994-1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 10:07:22 AM
Creation date
1/4/2022 2:17:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
1994-1995
RECORD_ID
PR0440004
PE
4433 - LANDFILL DISPOSAL SITE
FACILITY_ID
FA0004517
FACILITY_NAME
FOOTHILL LANDFILL
STREET_NUMBER
6484
Direction
N
STREET_NAME
WAVERLY
STREET_TYPE
RD
City
LINDEN
Zip
95236
APN
09344002
CURRENT_STATUS
Active, billable
SITE_LOCATION
6484 N WAVERLY RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
Site Address
6484 N WAVERLY RD LINDEN 95236
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
244
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> MONITORING AND REPORTING PROGRAM <br /> FOR FOOTHILL SANITARY LANDFILL <br /> CLASS III LANDFILL <br /> SAN JOAQUIN COUNTY <br /> For any given monitored medium, a sufficient number of samples shall be taken from all <br /> Monitoring Points and Background Monitoring Points to satisfy the data analysis <br /> requirements for a given Reporting Period, and shall be taken in a manner that ensures <br /> sample independence to the greatest extent feasible. <br /> Ground water sampling shall also include an accurate determination of the ground water <br /> surface elevation and field parameters (pH, temperature, electrical conductivity, turbidity) <br /> for that Monitoring Point or Background Monitoring Point. Ground water elevations <br /> taken prior to purging the well and sampling for Monitoring Parameters shall be used to <br /> fulfill the ground water gradient/direction analyses required. For each monitored ground <br /> water body, the Discharger shall measure the water level in each well and determine <br /> ground water gradient and direction at least quarterly, including the times of expected <br /> highest and lowest elevations of the water level for the respective ground water body. <br /> Ground water elevations for all background and downgradient wells for a given ground <br /> water body shall be measured within a period of time short enough to avoid temporal <br /> variations in ground water flow which could preclude accurate determination of ground <br /> water gradient and direction. This information shall be included in the quarterly <br /> monitoring reports. <br /> Statistical or non-statistical analysis should be performed as soon as the monitoring data <br /> are available. <br /> 4. Ground Water Monitoring <br /> Field and laboratory tests shall be reported in the quarterly monitoring reports. All <br /> "Monitoring Parameters" shall be graphed so as to show historical trends at each well. <br /> The ground water surface elevation (in feet and hundredths, M.S.L.) in all wells shall be <br /> measured on a quarterly basis and used to determine the velocity and direction of ground <br /> water flow. This information shall be displayed on a water table contour map and/or <br /> ground water flow net for the site and submitted with the quarterly monitoring reports. <br /> The monitoring network shall consist of monitoring wells MW-1, MW-2, and production <br /> well LW-1. Locations of these wells are shown on Attachment B. Any additional <br /> monitoring wells constructed at the site shall be added to the monitoring network. Well <br /> LW-1 may be removed from the monitoring network with the approval of Board Staff. <br /> Samples shall be collected from all wells at the frequency and for the parameters specified <br /> in Table H. Ground water samples shall be analyzed for the monitoring parameters shown <br /> in Table H. <br />