Laserfiche WebLink
A NJ O A Q U l N Environmental Health Department <br /> COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TOKAY SHELL 420 W KETTLEMAN LN, LODI January 07, 2022 <br /> Single-Walled Non-Pressurized Piping <br /> 404 CCR 2643(e),2661(f) Failure to conduct 0.1 gph test on single-walled gravity piping biennially or post repair(pre-1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 102 CCR 2711 Failure to submit a complete and accurate application for a permit to operate a UST. <br /> OBSERVATION: UST Tank Information forms are not current in the California Environmental Reporting System <br /> (CERS). <br /> •The Date UST System Installed is inaccurate. Per EHD records,the UST system was installed 2/24/1987. <br /> •The Tank Capacity in Gallons is inaccurate. Per EHD records, the UST system tank capacity is 550-gallons. <br /> •The Product/Waste Piping Construction is inaccurate. Since there is no piping in this UST system,the Piping <br /> Construction should be listed as'Other'. <br /> •The Product/Waste Piping Primary Containment is inaccurate. Since there are no piping in this UST system,this <br /> should be'none'. <br /> •The Vent Primary Containment is inaccurate.This should be'fiberglass'. <br /> •The Riser Pipe Primary Containment is inaccurate.This should be'Steel'. <br /> •The Fill Components Installed-Spill Bucket is inaccurate.This should be'yes'. <br /> •The Fill Components Installed-Striker Plate/Bottom Protector is answered as'no'.All UST systems are required <br /> to have a striker plate or drop tube-mounted bottom protector installed to prevent damage to the tank. Please verify <br /> if there is a striker plate installed or install a drop tube-mounted bottom protector if the striker plate cannot be <br /> verified. <br /> •Corrosion Protection was not specified. <br /> REGULATION GUIDANCE:Any change of information must be updated in CERS within 30 days of the changes. <br /> CORRECTIVE ACTION: Immediately log into CERS, update the required information, and submit for review by the <br /> EHD. <br /> This is a repeat violation, Class II. <br /> 104 CCR 2632(d)(1), 2634(d)Failure to have an approved UST Monitoring Plan. <br /> OBSERVATION: The monitoring plan is not current and/or not approved by the EHD. <br /> •The Tank Monitoring Leak Sensor Model is inaccurate. It is listed as Veeder Root 302 but a Veeder Root 301 was <br /> observed on site. <br /> •Secondary Containment Testing Periodic Testing is inaccurate. It is listed as'yes'but should be listed as'no'. <br /> REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting <br /> System (CERS). <br /> CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the <br /> EHD. <br /> This is a repeat violation, Class II. <br /> FA0024739 PR0544259 SCO01 01/07/2022 <br /> EHD 23-01 Rev.12/06/2021 Page 4 of 10 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />