Laserfiche WebLink
REVISIONS <br /> TENTATIVE IMPROVEMENT PLANS FOR: NO. DATE: DESCRIPTION <br /> SMA CAK S BAK RY STOR 1 5/18/21 LBID- 1ST REVIEW <br /> 15040 S. HARLAN ROAD, CITY OF LATHROP, STATE OF CALIFORNIA, 95330 <br /> WITHIN PARCEL=APN: 196- 11-020 , <br /> of <br /> PANEL BOARD SCHEDULE PANEL BOARD SCHEDULE ° <br /> PANEL BOARD DESIGNATION: SMALLCAKES TYPE OF PANEL: CIRCUIT BREAKER MOUNTING: MAIN LUGS PANEL BOARD DESIGNATION: SMALLCAKES TYPE OF PANEL: CIRCUIT BREAKER MOUNTING: MAIN LUGS <br /> 1Q05/18/21 LBID <br /> 4TH COMMENT VOLTAGE: 120/208-3PH 4-W BUS SIZE(AMPS): IOKA MAIN SWITCH: BELOW VOLTAGE: 110/220-3PH 4-W BUS SIZE(AMPS): IOKA MAIN SWITCH: BELOW I + <br /> POLES: 1 TOTAL SPACE PROVIDED: 14 NOTES:N/A POLES: 1 TOTAL SPACE PROVIDED: 14 NOTES:N/A <br /> FEEDER:N/A AMPS INTERRUPTING RATING: 130KA MANUFACTURER: SQUARE D TYPE NF FEEDER:N/A AMPS INTERRUPTING RATING: 130KA MANUFACTURER: SQUARE D TYPE NF p I } I <br /> C C T P P T C C C C T P P T C C w 'i <br /> LOAD DESIGNATION CONNECTED VA LOAD DESIGNATION LOAD DESIGNATION CONNECTED VA LOAD DESIGNATION <br /> K O R O O R O K K O R O O R O K � '?_ <br /> T D I L DESCRIPTION AO BO Co ABC AO BO CO DESCRIPTION L I D T T D I L DESCRIPTION AO BO Co ABC AO BO Co DESCRIPTION L I D T <br /> # E P E I E P E # # E P E I E P E # <br /> 1 N 10 1 OVERHEAD LIGHTS-MID BULBS 12.00 6.00 RECEPTACLES-EAST WALL 1 10 R 2 1 N 10 1 OVERHEAD LIGHTS-MID BULBS 12.00 6.00 RECEPT.-EAST WALL(REW)#1 1 10 R 2 <br /> 3 N 10 1 OVERHEAD LIGHTS-OUT BULBS 18.00 9.00 RECEPTICLES-WEST WALL 1 10 R 4 3 N 10 1 OVERHEAD LIGHTS-OUT BULBS 18.00 9.00 RECEPT.-WEST WALL(RWW) 1 10 R 4 - <br /> 5 N 10 1 OVERHEAD LIGHTS-6 FRONT 12.00 6.50 RECEPT. CEILING/DUCT DETECTOR 1 10 R 6 5 N 10 1 OVERHEAD LIGHTS-6 FRONT 12.00 6.50 RECEPT. CEILING/DUCT DETECTOR 1 10 R 6 <br /> 7 C 10 1 EXIT SIGNS (2) .40 - RECEPT. CEILING W/S 1 10 R 8 7 C 10 1 EXIT SIGNS (2) .40 - RECEPT. CEILING W/S 1 10 R 8 J ' <br /> 9 - 10 1 SPARE - 7.20 BATHROOM(ALL ELECTRICAL) 1 10 N 10 9 R 10 1 (NEW)RECEPT. IN STORAGE ROOM 1.5 7.20 BATHROOM(ALL ELECTRICAL) 1 10 N 10 ° ° a <br /> 1Q 05/18/21 LBID <br /> 11 - 10 1 SPARE - SPARE 1 10 - 12 1ST COMMENT 11 R 10 1 (NEW)4 RECEPT. IN OFFICE 6.0 8.30 (REW)#2(NEW)CONE BAKER 1 15 N 12 V �, <br /> 13 - 10 1 SPARE - 4 - SPARE 1 10 - 14 13 N 10 1 (NEW)ICE CREAM DISPLAY 7.1 8,5 (NEW)REACH IN FREEZER 1 15 N 14 o <br /> 15 - SPARE 1 10 - 16 15 R 10 1 (NEW)RECEPT.FOR(2) 50" TV'S 1.5 7.50 (NEW)REACH IN FRIDGE 1 15 N 16--------------- <br /> t~�� <br /> 17 18 05/18/21 LBID 17 - 18 [�] <br /> 19 20 3RD COMMENT 19 N 30 1 (NEW)BATCH FREEZER 20 20 W ^ <br /> 21 22 21 R 10 1 (NEW)RECEPT.FOR REGISTER(POS) 1.5 22 <br /> 23 24 23 24 Z <br /> 25 26 =29 <br /> 26 Z <br /> 1Q 05/18/21 LBID <br /> 27 28 2ND COMMENONVECTION OVEN-3PH 31 28 p <br /> 29 30 30 e - a <br /> 31 32 31 32 U o <br /> 33 12.70 HVAC-4TON ON ROOF 1 30 N 34 33 12.70 HVAC-4TON ON ROOF 1 30 N 34 <br /> 35 36 35 36 �1 <br /> 37 38 37 38 <br /> 39 HEAT PUMP-ON ROOF W/HVAC 1 30 N 40 39 HEAT PUMP-ON ROOF W/HVAC 1 30 N 40 e <br /> 41 42 41 42 <br /> 0 O °1 a <br /> CIRCUIT CODE TOTALS PHASES A B C TOTAL CONNECTED VA 209.94 CIRCUIT CODE TOTALS PHASES A B C TOTAL CONNECTED VA 82.40 <br /> C : CONTINUOUS 65.00 TOTALS 44.70 88.24 77.00 CONNECTED VA(CODE N) 92.54 C : CONTINUOUS - TOTALS 35.60 7.50 39.30 CONNECTED VA(CODE N) 82.40 O <br /> N :NON-CONTINUOUS 92.54 CONNECTED VA(CODE C) 65.00 N :NON-CONTINUOUS 82.40 CONNECTED VA(CODE C) 0.00 W M <br /> OR : RECEPTACLES 52.40 (CODE C)X 1.25=# 81.25 R : RECEPTACLES - (CODE C)X 1.25=# 000 V 1 Q <br /> M: LARGEST MOTOR 25.00 ADJUSTED VA(CODE C) 16.25 M: LARGEST MOTOR 7.10 ADJUSTED VA(CODE C) 0.00 <br /> K: KITCHEN EQUIPMENT 45.40 CONNECTED VA(CODE R) 52.40 K: KITCHEN EQUIPMENT 67.00 CONNECTED VA(CODE R) 0.00 <br /> (CODE R)- 10,000= # 9947.60 (CODE R)- 10,000= # 0.00 aJ Z , <br /> #X50%- 4973.80 #X50%- 0.00 1 = -C� 0 <br /> ADJUSTED VA(CODE R) 4921.40 ADJUSTED VA(CODE R) 0.00W v w 8 <br /> (CODE M)X 1.25 = 31.25 (CODE M)X 1.25 = <br /> 8.85 <br /> ADJUSTED VA(CODE M) 6.25 (CODE M) 1.75 <br /> ADJUSTED VA ,,��// O <br /> CONNECTED VA(CODE K) 45.40 CONNECTED VA(CODE K) 67.00 W O `� <br /> (CODE K)X.65=# 29.51 (CODE K)X .65=# 43.55 W �p <br /> ADJUSTED VA(CODE K) 15.89 ADJUSTED VA(CODE K) 23.45 <br /> TOTAL ADJUSTED KVA+(CODE N) 5052.33 TOTAL ADJUSTED KVA+(CODE N) 107.60 <br /> EXISTING ELECTRICAL PANEL PLAN PROPOSED ELECTRICAL PANEL PLAN <br /> SCALE: N.T.S. SCALE: N.T.S. <br /> .--------------------------------. TWA <br /> 12",U,NLESS CEILING IS CEILING <br /> HIGHER THAN 12'-0", O ^ M <br /> THEN 24 ABOVE DOOR <br /> WALL MOUNTED LIGHT Q O O Z <br /> FIXTURE. MOUNT AT 8'-0" <br /> ABOVE FINISHED FLOOR Z a <br /> ALIGN WHEN MOUNTED OR 6 BELOW CEILING TO �j Q <br /> ON SAME WALL i CENTER OF LIGHTWALL <br /> a x <br /> x <br /> LIGHT SWITCH OR MOUNTED TOP OF ~ [� <br /> DIMMER i COUNTER . p.. <br /> TELEPHONE BACKSPLASH W (G-I <br /> RFCEFACI,F O <br /> CA <br /> RECEPTACLE 6 �] <br /> TELE/DATA OUTLET i TELE/DATA UNAUTHORIZED CHANGES&USES: <br /> 48" 48" OUTLET The design firm preparing these plans will not be responsible for,or liable for, <br /> ABOVE unauthorized changes to or uses of these plans.All changes to these plans MUST be in <br /> " COUNTER writing and must be approved by the preparer of these plans. <br /> PERMIT NOTE: <br /> The issuance of a permit or approval of plans or specifications shall not be deemed or 18" CHECKED BY: J.AGUIRRF (E.O.R.) <br /> construed to be a permit for an approval of any violation of any of the provisions of the FLOOR G.MENDOZA <br /> California state building codes or local ordinances. I CONSTRUCTION CONTRACTOR NOTE: DESIGNED BY: PHANTOM DESIGNS <br /> 1 05/18/21 LBIDG.MENDOZA <br /> Construction contractor agrees that in accordance with generally acepted construction DRAWN BY: PHANTOM DESIGNS <br /> 5TH COMMENT practices,construction contractor will be required to assume sole and complete <br /> NOTES: Responsibility for job site conditions during the course of constructionof the project, SCALE: SCALE: 1/4"= 1'-0" <br /> DESIGN NOTE: 1. ALL DIMENSIONS ARE TO TOP OR BOTTOM OF including safety of all persons and property;that this requirement shall be made to apply <br /> Electronic versions of the line work on this plan may not be consistent with other DEVICE,UNLESS OTHERWISE NOTED(REGARDLESS continuously and not to be limited to normal working hours, and construction contractor DATE: 04/30/2021 <br /> dimensions,notes,details,or descriptions which control the intent design. electronic OF WHAT DRAWING SHOWS). further agrees to defend,imdemnify and hold design professional harmless from any <br /> versions of the plan are not to be used to establish the location of property or and all liability,real or alleged,in connection with the performance of work on this <br /> improvements in the field. DEVICE MOUNTING ELEVATION project, except liability arising from the sole negligence of the design professional. <br /> SCALE:N.T.S. X5 ,00 <br />