Laserfiche WebLink
MONITORING WELL PLUG <br /> 2"MIN CLEAR <br /> IN ENCLOSURE WELL ENCLOSURE WITH <br /> LOCKABLE COVER,CENTERED ON BOTH <br /> PIPES <br /> 'v <br /> 1/2"x4"GALV CARRIAGE BOLT IN WET <br /> F CONCRETE HEAD FLUSH W/CONCRETE <br /> LL 4" <br /> M <br /> 2 FT CONCRETE PAD <br /> INSCRIBE WELL NO.AND DATE IN WET <br /> CONCRETE <br /> a' <br /> 4. ° a a e <br /> a � _ <br /> GROUND SURFACE(EL 214 APPROX) "��"-" <br /> u- v. e 4 a <br /> a <br /> DORIES,3 MIN <br /> CENTRALIZER(TYP). 20 FT O.0 <br /> v FOR AIR AND MUD ROTARY RIG INSTALLATION <br /> Lu <br /> ONLY <br /> 0 <br /> O z <br /> Lu <br /> a w <br /> a U) <br /> a o <br /> N z EAT CEMENT SEAL(TYP) <br /> n, POURED IN TWO LIFTS,MAX 100 FT EA LIFT. <br /> u w <br /> x <br /> CL z ENTONITE <br /> Lu 0 <br /> U <br /> w uj <br /> CL o <br /> z <br /> i <br /> w Lo <br /> Lo <br /> GROUNDWATER TABLE(EL 37 APPROX) <br /> SAND PACK(TYP) <br /> 4"PVC WELL CASING <br /> NOTES: <br /> Lo .02"SLOTTED WELL SCREEN(TYP) <br /> 1. ACTUAL DEPTH VARIES BASED ON N <br /> ELEVATION OF GROUNDWATER <br /> 2. INSTALL TWO BOLLARDS (NOT SHOWN) 1"SLOTTED PVC SOUNDER PIPE <br /> 3. GROUNDWATER PUMP NOT SHOWN. <br /> INSTALL GROUNDWATER PUMP AS 1 ft <br /> DIRECTED BY THE ENGINEER. <br /> THREADED BOTTOM CAP <br /> 4. PRESENCE OF SAN JOAQUIN COUNTY3/8"0 HOLE <br /> EHD IS REQUIRED FOR PLACING -� <br /> MATERIALS WITHIN THE BOREHOLE, UP ' 1U ' <br /> TO THE NEAT CEMENT SEAL. <br /> COORDINATE EHD INSPECTION WITH NOT TO SCALE <br /> THE ENGINEER. R@VIS@d Jan. 22, 2015 <br /> N:\Miscellaneous\Drawings\StdDwgs\GW Well DWG\MW-6 Workplon.dwg <br /> FOOTHILL PROPOSED GROUNDWATER <br /> COUNTY OF SAN JOAQUIN SANITARY FIGURE 2 <br /> LANDFILL MONITORING WELL MW-6 <br />