COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DUCK CREEK
>
3633
>
2300 - Underground Storage Tank Program
>
PR0232461
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2022 4:53:35 PM
Creation date
1/10/2022 9:26:57 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0232461
PE
2361
FACILITY_ID
FA0003758
FACILITY_NAME
RYDER TRUCK RENTAL #1071
STREET_NUMBER
3633
STREET_NAME
DUCK CREEK
STREET_TYPE
DR
City
STOCKTON
Zip
95215
APN
17331001
CURRENT_STATUS
01
SITE_LOCATION
3633 DUCK CREEK DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEAK MIN PERIODIC: 4% <br /> 80 LIQUID SENSOR SETUP_ _ L14:DISP 4 SAT UDC 208 <br /> LEAK MIN ANNUAL 50i TRI-STATE (SINGLE FLOAT) <br /> 1000 L I :TI DSL INT 420 CATEGORY DISPENSER PAN <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : ANNULAR SPACE <br /> PERIODIC TEST TYPE L15:T3 MOTOR OIL TSS 208 <br /> STANDARD TRI-STATE (SINGLE FLOAT) <br /> ANNUAL TEST FAIL L 2:T1 DSL FILL 208 CATEGORY PIPING SUMP <br /> ALARM DISABLED TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : PIPING SUMP L16:T4 UO PS 208 <br /> PERIODIC TEST FAIL TRI-STATE (SINGLE FLOAT) <br /> ALARM ENABLED <br /> L 3:T1 DSL STP 205 CATEGORY PIPING SUMP <br /> GROSS TEST FAIL TRI-STATE (SINGLE FLOAT) <br /> ALARM ENABLED ( CATEGORY : STP SUMP L17:T4 UO INT 420 <br /> ANN TEST AVEkAGING: OFF TRI-STATE (SINGLE FLOAT) <br /> CATEGORY ANNULAR SPACE <br /> PER TEST AVERAGING: OFF L 4:T2 DSL INT 420 <br /> TRI-STATE (SINGLE FLOAT) <br /> TANK TEST NOTIFY: OFF CATEGORY : ANNULAR SPADE <br /> TNK TST SIPHON BREAKOFF L18:T4 UO FILL 208 <br /> TRI-STATE (SINGLE FLOAT) <br /> DELIVERY DELAY 5 MIN L 5:T2 DSL FILL 208 CATEGORY : PIPING SUMP <br /> PUMP THRESHOLD 10.00%4 TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : PIPING SUMP <br /> L 6:T2 DSL STP 205 <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY STP SUMP <br /> L 7:T3 MO INT 420 <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY ANNULAR SPACE OUTPUT RELAY SETUP <br /> LEAK TEST METHOD <br /> TEST WEEKLY : TANK 1 L 8:T3 MO FILL 208 k 1 :DIESEL MAIN PSD <br /> MON TRI-STATE (SINGLE FLOAT) TYPE: <br /> START TIME : DISABLED CATEGORY : PIPING SUMP STANDARD <br /> TEST RATE :0.20 GAL/HR NORMALLY CLOSED <br /> DURATION 2 HOURS <br /> L 9:MO STP 208 LIQUID SENSOR ALMS <br /> TST EARLY STOP:DISABLED TRI-STATE (SINGLE FLOAT) L 1 :FUEL ALARM <br /> CATEGORY : STP SUMP L 2:FUEL ALARM <br /> TEST WEEKLY : TANK 2 L 3:FUEL ALARM <br /> MON L10:DISP 1-2 MST UDC 208 L10:FUEL ALARM <br /> START TIME : DISABLED TRI-STATE (SINGLE FLOAT) L11 :FUEL ALARM <br /> TEST RATE :0.20 GAL/HR CATEGORY : DISPENSER PAN L1I :FUEL ALARM <br /> DURATION 2 HOURS L 1 :SENSOR OUT ALARM <br /> L 2:SENSOR OUT ALARM <br /> TST EARLY STOP:DISABLED L 3:SENSOR OUT ALARM <br /> L11 :UISF 1 SAT UDC 208 L10:SENSOR OUT ALARM <br /> L11 :SENSOR OUT ALARM <br /> TRI-STATE (SINGLE FLOAT) <br /> TEST WEEKLY : TANK 3 CATEGORY : DISPENSER PAN L1I :S£NSOR OUT ALARM <br /> L :SHORT ALARM <br /> MON <br /> START TIME : DISABLED L 2:SHORT ALARM <br /> TEST RATE :0.20 GAL/HR L 3:SHORT ALARM <br /> DURATION 2 HOURS L12:DISP 2 SAT UDC 208 L10:SHORT ALARM <br /> L11 :SHORT ALARM <br /> TRI-STATE (SINGLE FLOAT) <br /> TST EARLY STOP:DISABLED CATEGORY : DISPENSER PAN L12:SHORT ALARM <br /> TEST DAILY TANK 4 <br /> : 1 :00 Af°1 L13:DISP 3-4 MST UDC 208 <br /> START TIME TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : DISPENSER PAN <br /> TEST RATE:0.20 0 AGAL/HR <br /> DURATION : 2 HOURS <br /> TST EARLY STOP:DISABLED <br /> LEAK TEST REPORT FORMAT <br /> NORMAL <br />