A <br /> B - <br /> A 15' ORLESS < B A/R HEATING VENTILATING AND AIR CONDITIONING SYMBOLS -► <br /> O K� 15' OR LESS0 <br /> OW <br /> SYMBOL DESCRIPTION SYMBOL DESCRIPTION <br /> TRANSFORMATION EXPANSION CONTRACTION —r—=FW MANUAL VOLUME DAMPER <br /> THERMOSTAT WITH CONTROL WIRING <br /> -C=-MD MOTORIZED DAMPER <br /> TURN/W2/31D <br /> OH HUMIDISTAT (BY EQUIPMENT MANUFACTURER) -r-=I-FD FIRE DAMPER <br /> VANE ROUND DUCT RISER OR DROP -C=I-SD SMOKE DAMPER <br /> 0 <br /> TURN/NG p SUPPLY OR OUTDOOR AIR DUCT RISER <br /> -C=-FD,SD COMBINATION FIRE AND SMOKE DAMPER <br /> VANES ` OR DROP (SA OR OA) SQUARE/RECTANGULAR DIFFUSER WITH-21D AIRFLOW TAG. SEE SCHEDULE FOR EXACT <br /> THREE RETURN OR EXHAUST AIR DUCT RISER L9400�� DIFFUSER TYPE. PROVIDE SECTORIZING CO 2020 STARBUCKS COFFEE COMPANY <br /> TURN/NG VANES �D� OR DROP (RA OR EA) 10 0 D-X BAFFLES TO ACHIEVE AIRFLOW PATTERN R <br /> 90' ELBOW � S � <br /> SHOWN. <br /> 45' ELBOW SIMILAR NO THROAT RADIUS SHORT RADIUS FULL RADIUS 1016 RECTANGULAR DUCT WITH SIZE <br /> FIRST FIGURE IS SIDE SHOWN "t\-\ 2401 UTAH AVENUE SOUTH <br /> ROUND DUCT WITH SIZE 00 CFM ROUND DIFFUSER WITH AIRFLOW TAG SEATTLE, WASHINGTON 98134 <br /> 1010 D-X SEE SCHEDULE FOR EXACT DIFFUSER TYPE (206 318-1575 <br /> 0 /-10-0 <br /> FLEXIBLE DUCT WITH SIZE <br /> THESE DRAWINGS AND THE PROJECT MANUAL <br /> QZ SQUARE/RECTANGULAR SUPPLY GRILLE ARE CONFIDENTIAL AND SHALL REMAIN THE <br /> 0 z ��' ELBOW WITH TURNING VANES F WITH AIRFLOW TAG. SEE SCHEDULE FOR SOLE PROPERTY OF STARBUCKS <br /> 400 CFM_ EXACT DIFFUSER TYPE. ADJUST BLADES CORPORATION,WHICH IS THE OWNER OF THE <br /> Nm- EXISTING 12 s D OR PATTERN CONTROLLER TO ACHIEVE COPYRIGHT IN THIS WORK. THEY SHALL NOT BE <br /> SUPPLY OR RETURN WYE TURN/NG VANES _ AIRFLOW PATTERN SHOWN. REPRODUCED(IN WHOLE OR IN PART), SHARED <br /> o NEW WORK <br /> (RECTANGULAR DUCT) a1, WITH THIRD PARTIES OR USED IN ANY MANNER <br /> p POINT OF CONNECTION BETWEEN NEW AND 100 CFM EXHAUST AIR GRILLE WITH AIRFLOW TAG ON OTHER PROJECTS OR EXTENSIONS TO THIS <br /> o <br /> X EXISTING WORK. 616 G-X SEE SCHEDULE FOR EXACT GRILLE TYPE PROJECT WITHOUT THE PRIOR WRITTEN <br /> CONSENT OF STARBUCKS CORPORATION. <br /> ;3/4 <br /> 1,200 CFM OAS MINIMUM OUTDOOR AIR -XRETURN AIR GRILLE WITH TAG INTENDEDTHESE RTO EXRESS DESICGNAND CINTEONNFORA <br /> ARE <br /> SEE SCHEDULE FOR EXACT GRILLE TYPE <br /> D1PROTOTYPICAL STARBUCKS STORE(WHICH IS <br /> DUCT SMOKE DETECTORHATCH PATTERN INDICATES ITEMS BEINGSUBJECT TO CHANGE AT ANYTIME)AND DO NOT <br /> REMOVED. REFLECT ACTUAL SITE CONDITIONS. NEITHER <br /> I�D�I D 90' ELBOW TAKE—OFF PARTY SHALL HAVE ANY OBLIGATION NOR <br /> RETURN AIR BRANCH USE ONLY IN AREAS FULL RADIUS ELBOW NOTE: NOT EVERY DEVICE OR SYMBOL IN THIS LEGEND MAY BE USED ON THIS PROJECT. LIABILITY TO THE OTHER(EXCEPT STATED <br /> FITTING WHERE SPACE IS LIMITED TAKE—OFF ABOVE) UNTIL A WRITTEN AGREEMENT IS FULLY <br /> HEATING VENTILATING AND AIR CONDITIONING ABBREVIATIONS EXECUTED BY BOTH PARTIES. <br /> ABBREVIATION TERM ABBREVIATION TERM STARBUCKS TEMPLATE VERSION: 12020-01-31.1 <br /> DUCTWORK DETAILS <br /> 4 AFF ABOVE FINISHED FLOOR MBH 1000 BTU PER HOUR ARCHITECT OF RECORD <br /> NOT TO SCALE CFM CUBIC FEET PER MINUTE FA OR OA OUTDOOR AIR Eg <br /> EA EXHAUST AIR RA RETURN AIR cc <br /> = o <br /> ii U <br /> HVAC HEATING VENTILATING AND AIR CONDITIONING SA SUPPLY AIR <br /> cc <br /> Cn <br /> H . V. A. C. SYMBOLS mcg arc i`A92618 <br /> 2 15635 Alton Parkway,Suite 100, Irvine,CA 92618 <br /> P:949.553.1117 F:949.474.7056 <br /> NOT TO SCALE <br /> ARCHITECT STAMP �5 <br /> Q�G <br /> MAX. OF 12 TO BRANCH CONNECT/ON <br /> UNLESS NOTED OTHERWISE <br /> o GAL VAN/ZED SHEET METAL Q�Q <br /> DUCT AND INSULA TION 11-19-21 <br /> Sb PER SPEC/F/CA TIONS <br /> USE RIGID GALVANIZED <br /> 90 DEGREE ELBOW <br /> ° <br /> 90 F1 VE SEC TION 45 THREE SECTION METAL STRAP CLAMP <br /> ELBOW ELBOW GAL VANIZED SHEET METAL (TYPICAL) 2 PLACES <br /> DUCT AND INSULA TION INSULATED FLEXIBLE DUCT <br /> PER SPEC/F/CA T/ONS <br /> (MIN 2; MAX. 5; NO MORE <br /> VOLUME DAMPER LOCA TED OPPOSED THAN ONE 90' BEND) <br /> IN ACCESSIBLE L OCA TION. BLADE DAMPER <br /> 0 <br /> PROVIDE ACCESS DOOR OR A TD/FFU TRANS/T/ON FITTING <br /> 90 , , CABLE OPERATOR /F NOT AS REQUIRED Z 0 <br /> 45 ACCESS/BLE. INSULA TE DIFFUSER SUPPL Y AIR DIFFUSER <br /> BACK AND SEAL W/TV TYPE AS INDICA TED - <br /> VAPOR BARRIER TAPE ON SCHEDULE — CN <br /> coCn <br /> 07 <br /> E: Ww � � Q <br /> I U <br /> 90 *BRA NCH TAKE-OFF 45 BRANCH TAKE-OFF i Q (D p .. <br /> z m Q � <br /> TYPICAL ROUND DUCT FITTINGS TYPICAL DIFFUSER CON N ECTI ON 04-0 <br /> 3 1 W �S W r <br /> --3 <br /> NOT TO SCALE NOT TO SCALE O LO O 0 <br /> 4—+ <br /> 6- O co Cn <br /> STORE #: 20685 <br /> PROJECT#: 59335-039 <br /> ISSUE DATE: CHECKSET <br /> DESIGN MANAGER: J.RAMOS <br /> PRODUCTION DESIGNER: <br /> CHECKED BY: GRS <br /> MCG PROJECT#: 21324 <br /> MCG PROJ. MANAGER: J.SPENCER <br /> MCG PROJ. SPECIALIST: <br /> Revision Schedule <br /> Rev Date By Description <br /> SHEET TITLE: <br /> MECHANICAL DETAILS <br /> SCALE:AS SHOWN <br /> SHEET NUMBER: <br /> M-5001 <br />