Laserfiche WebLink
Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Date: <br />December 22, 2022 <br /> Facility Address: <br /> 85 E LOUISE AVE, LATHROP <br /> Facility Name: <br /> ARCO 06080 <br />Single-Walled Non-Pressurized Piping <br /> 404 □ V □ R □ COSFailure to conduct 0.1 gph test on single-walled gravity piping biennially or post repair (pre-1984)CCR 2643(e), 2661(f) <br />Other Violations <br /> 2010 □ V □ R □ COSUnlisted General violation See below <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 214 CCR 2712 Failure to comply with UST operating permit conditions. <br />OBSERVATION: This facility is not in compliance with the written conditions of the operating permit due to the <br />following; on June 22, 2022 a cold start was performed and no functionality testing was conducted and on June 24, <br />2022 another cold start was performed and EHD was notified late on 11/22/2022 and functionality testing was <br />conducted late on 12/22/22. <br />REGULATION GUIDANCE: The owner and operator of underground storage tank (UST) systems shall comply with <br />all requirements of the permit issued for the operation of the UST system. <br />CORRECTIVE ACTION: Immediately take all necessary actions to bring these UST systems into compliance. <br />This is a minor violation. <br /> 307 HSC 25290.1(c3), 25290.2(c3) Failure to keep water out of the secondary containment system (post-Jul 2003). <br />OBSERVATION: Water was found in the diesel , 91, 87 STP and vent sumps. <br />REGULATION GUIDANCE: Secondary containment shall be constructed to prevent any water intrusion into the <br />system by precipitation, infiltration, or surface runoff. <br />CORRECTIVE ACTION: The service technician removed approximately one gallon of liquid from the diesel, 87, 91 <br />STP and vent sumps and returned the sensor to its proper location. Immediately contact a properly licensed, <br />trained, and certified contractor to address the water intrusion into the diesel, 91, 87 STP and vent sumps under <br />permit and inspection of the EHD. <br />This is a repeat violation, Class II. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 1/21/2023 . <br />To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br />of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br />($156). To schedule an appointment, please call (209) 468-3420. <br />FA0003635 PR0231656 SC001 12/22/2022 <br />EHD 23-01 Rev. 12/06/2021 Underground Storage Tank Program OIRPage 4 of 5 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD