i
<br /> Ip
<br /> a SPANNER LIGHTS
<br /> J SEAL (TYP.)
<br /> CD
<br /> I U_ DISPENSER ttC
<br /> N� Q A tl')
<br /> U N¢ BUILDING WALLEn
<br /> n
<br /> I
<br /> PVC COATED RIGiD CONDUIT j
<br /> ❑ ❑ ❑ PVC CONDUIT LO
<br /> tt')
<br /> PVC TO METAL CONDUIT N
<br /> COUPLER (TYP.)
<br /> J J
<br /> N PVC COATED RIGID STEEL
<br /> CONDUIT
<br /> CONDUIT ENTRY TO DISPENSER co
<br /> PER DISPENSER MANUFACTURER. O �
<br /> SEAL PER N.E.C. CU *
<br /> NOTES: DISPENSER SUMP
<br /> CLASS 1 , 1. THREADED PVC COATED RiGID METAL CONDUIT SHALL BE USED FOR THE S
<br /> LAST 2 FEET OF UNDERGROUND RUN TO EMERGENCE PER N.E.C. 514. cn
<br /> DIVISION 2 2. UNDERGROUND PVC CONDUIT SHALL BE USED ONLY AS ALLOWED BY N.E.C. 514-8, O
<br /> LOCATION EXCEPTION NO, 2 AND APPLICABLE LOCAL CODES. VERIFY SUITABILITY WITH ALL
<br /> APPROPRIATE AGENCIES. PVC CONDUIT SHALL BE SCHEDULE 40 OR HEAVIER WITH
<br /> B
<br /> ALL PORTIONS BURIED A MINIMUM 2 FEET BELOW GRADE.
<br /> CLASS 1 , CONDUIT STUB -- UP
<br /> DIVISION 1
<br /> LOCATION F_g SCALE: NTS
<br /> I � a
<br /> DISP.
<br /> PZ=208.5' C
<br /> C DISP.
<br /> C o 0
<br /> A
<br /> 'j O TANK FILL 1 _ PLAN
<br /> A C I I p CLASS 1 ,
<br /> CLASS 1 , pK DIVISION 1
<br /> Cr
<br /> n bm
<br /> DIVISION 2 o Q a ° 0 000
<br /> LOCATION O
<br /> 'P ' N 0 ¢ JUNCTION BOX (TYP.)
<br /> o J © LOCATE PER MANUFACTURER'S
<br /> nEM M
<br /> o J SPECIFICATIONS
<br /> l�
<br /> C ° ewsna o-sra+z I
<br /> i
<br /> i
<br /> E UNION CROUSE HINDS
<br /> TURBINE SUMP I ELEVATION CAT. #UNY OR EQUAL (TYP)
<br /> 13
<br /> SEAL FITTING, CROUSE—HINDS
<br /> CLASS 1 ,
<br /> DIVISION 1 GAT. #EY5 OR EQUAL (TYP)
<br /> � �
<br /> CONDUIT ENTRY TO DISPENSER
<br /> PER DISPENSER MANUFACTURER.
<br /> (TYP. ALL) N.E.G.
<br /> !`COTES: SEAL PER
<br /> o IjEE
<br /> ?I 04
<br /> VERIFY MANUFACTURER'S DISPENSER DIMENSIONS, MODEL, AND JUNCTION BOX
<br /> O E ID O I Q II LOCATIONS PRIOR TO STUBBING CONDUITS.
<br /> !I CLASS 1 , DIVISION 1 0 I VERIFY ORIENTATION OF DISPENSERS PRIOR TO STUBBING CONDUITS.
<br /> AT DISPENSER SUMPS
<br /> 1
<br /> AND INSIDE DISPENSER
<br /> DISPENSER CONDUIT
<br /> (TYP. AT ALL DISPENSER II F—$ SCALE: NTS
<br /> LOCATIONS) N.E.C. HAZARDOUS AREA NOTES
<br /> DI A TYPICAL N.E.G. ARTICLE 514 CLASS 1 LOCATION (UNDERGROUND TANK - FILL OPENING)
<br /> q O EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION:
<br /> } or 2Anpit,
<br /> box.d locor atiace on.below grade level, any part of which is within the Division 1
<br /> EXTENT OF CLASS 1, GROUP D. DIVISION 2 LOCATION:
<br /> L _ _ _ _ _ _ — T - Up to 18 inches above grade level within a horizontal radius of 10 feetfram a loose
<br /> fill connection and within a horizontal radius of 5 feet from a tight fill connection.
<br /> I OTYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (UNDERGROUND TANK - VENT-DISCHARGING UPWARD)
<br /> EXTENT Within 3CfeetS1.of open end nd sof lvenit, extending In all directions.
<br /> EXTENT OF CLASS 1, GROUP 0, DIVISION 2 LOCATION:
<br /> Space between 3 feet and 5 feet of open and of vent, extending in all directions.
<br /> OTYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (REMOTE PUMP - OUTDOOR)
<br /> C EXTENT OF CLASS 1, GROUP D, DI1ASION 1 LOCATION:
<br /> Any pit, box, or space below grade level If any part is within a horizontal distance
<br /> of 10 feet from any edge of pump.
<br /> EXTENT OF CLASS 1, GROUP 0, DIVISION 2 LOCATION:
<br /> Within 3 feet of any edge of pump, extending in all directions, Also up to 18 Inches
<br /> above grade level within 10 feet horizontally from any edge of pump.
<br /> TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - PITS)
<br /> © EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION:
<br /> Any pit, box, or space below grade level, any part of which is within the Division 1
<br /> or 2 classified location.
<br /> TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - DISPENSER) Z
<br /> E EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: W
<br /> Space classification inside the dispenser enclosure is covered in ANSI/UL 87,
<br /> "Power Operated Dispensing Devices for Petroleum Products."
<br /> OTYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - DISPENSER) W
<br /> EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION:
<br /> Within 18 inches horizontally in all directions extending to grade from (1) the w
<br /> dispenser enclosure or (2) that portion of the dispenser enclosure containing
<br /> TYPICAL CLASS 1 D I VI I S I O N 1 1 liquid handling components. Space classification inside the dispenser enclosure J J
<br /> 0—is covered In ANSI/UL 87, "Power Operated Dispensing Devices for Petroleum
<br /> Products." W
<br /> 11
<br /> AND 2 H AZA R D O U S AREA PLAN o 10 20 40 so G TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - OUTDOOR) U LL L'i Q
<br /> SCALE: 1"=20' Q EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION:
<br /> Up to 18 inches above grade level within 20 feet horizontally of any edge of enclosure.
<br /> SCALE: 1 It= 20 , r W CD �
<br /> NOTES ~ U) �o 0
<br /> CONCRETE U w p W (Y
<br /> OR ASPHALT 1. ALL CONDUITS TO EXISTING TANKS ARE EXISTING. RECONNECT EXISTING CONDUITS TO NEW DISPENSERS. 1
<br /> COVER AT GRADE U �--
<br /> U4D8 QROIIM CONUff 800 DLU LTJ o Q 0000 J
<br /> DRAWN BY:.
<br /> REVIEWED BY:
<br /> CONDUIT CONDUCTOR CONDUIT ROUTING REMARKS DATE: 04.12.2022
<br /> NUMBER SIZE TYPE NO. SIZE TYPE FROMTO JOB NO: 21100042.2
<br /> 24 MIN. BACKFILL MATERIAL: (D 1" PVC 6 BELDEN #8760 TLS 350 ANNULAR SPACE MONITORING
<br /> / MONITOR PANEL MONITOR J-BOX
<br /> PEA GRAVEL (TYP.) O 3/4" PVC 2 BELDEN #8750 ANNULAR SPACE TANK FILL SUMP MONITORING
<br /> BELOW CONCRETE OR MONITOR J-Box
<br /> ASPHALT GRADE COVER, ANNULAR SPACE TANK TURBINE MONITORING
<br /> 1" PVC 4 BELDEN #8760 MONITOR J--BOX SUMP
<br /> TOP 01
<br /> CONDUIT o - - - . . �' 2+G #12 RUN < 100'
<br /> `:/ 3/4" RMC +G 10 THIN CIPS PUMP MOTOR
<br /> MIN. RUN > 100'
<br /> O 3/4" PVC 3 BELDEN #8760 ANNULAR SPACE VENT RISER MONITORING
<br /> MONfTOR J-BOX
<br /> 3„ MIN. 1„
<br /> MIN.
<br /> NOTE:
<br /> 1. BACK FILL AND COMPACTION FOR ALL. CONDUIT TRENCHES TO MEET, STATE, CITY,
<br /> COUNTY AND LOCAL REQUIREMENTS. SHEET
<br /> 2. BACKFILL AND COMPACTION FOR SERVICE LATERAL CONDUIT TRENCH TO MEET
<br /> LOCAL ELECTRIC UTILITY COMPANY REQUIREMENTS. IF SOIL IS NOT ROCK FREE,
<br /> ADD 4" TO DEPTH OF SERVICE LATERAL CONDUIT TRENCH. Ewl
<br /> 3 ENCH DETAILS
<br /> F-9 SCALE: NTS
<br />
|