Laserfiche WebLink
S A N J D AR I N Environmental Health Department <br /> U U ,t+ I Y <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHEVRON#208117** 755 S TRACY BLVD,TRACY February 16, 2022 <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 102 CCR 2711 Failure to submit a complete and accurate application for a permit to operate a UST. <br /> OBSERVATION: UST Tank Information forms are not current in the California Environmental Reporting System <br /> (CERS). The tank forms for the 87 and 91 tanks show that UDCs are single-walled fiberglass. On site <br /> double-walled fiberglass UDCs were observed. <br /> REGULATION GUIDANCE:Any change of information must be updated in CERS within 30 days of the changes. <br /> CORRECTIVE ACTION: Immediately log into CERS, update the required information, and submit for review by the <br /> EHD. <br /> This is a minor violation. <br /> 203 CCR 2712(b)(1-2)Failure to maintain monitoring records for 36 months and maintenance records for 60 months. <br /> OBSERVATION: Maintenance and monitoring records for the last three years were not found on site.The following <br /> was not observed on site: <br /> -The 1/17/2022 Secondary Containment Testing Report Form.The latest Secondary Containment Test results on <br /> site is 2/13/2019. <br /> REGULATION GUIDANCE: These records shall be maintained on site for at least three years. Monitoring records <br /> include: (1)date and time of all monitoring or sampling; (2)monitoring equipment calibration and maintenance <br /> records; (3)results of any visual observations; (4)results of sample analysis performed a lab or in the field; (5)logs <br /> of all readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6)results of <br /> inventory readings and reconciliations. <br /> CORRECTIVE ACTION: Immediately locate and maintain all missing maintenance and monitoring records for the <br /> last three years on site and submit copies to the EHD.A copy of the 1/17/2022 Secondary Containment Test <br /> Results was provided to manager via email during the inspection.This was corrected on site. <br /> This is a minor violation. <br /> 208 CCR 2716(a-e) Failure to comply with the designated operator inspection requirements. <br /> OBSERVATION: The designated operator failed to check and note the correct test dates for the Secondary <br /> Containment Testing on the designated operator inspection reports.The listed test date for Secondary Containment <br /> is 2/13/2019 but the correct date for Secondary Containment Testing is 1/17/2022. <br /> REGULATION GUIDANCE: During the inspection, the designated operator shall check that all required testing and <br /> maintenance for the UST system have been completed and document the dates they were done. <br /> CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are including all of <br /> the required information on the reports. <br /> This is a repeat violation, Class II. <br /> FA0007938 PR0508090 SCO01 02/16/2022 <br /> EHD 23-01 Rev.12/06/2021 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />