My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
14749
>
2800 - Aboveground Petroleum Storage Program
>
PR0515788
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/17/2023 12:32:26 PM
Creation date
1/20/2022 8:36:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0515788
PE
2832
FACILITY_ID
FA0000482
FACILITY_NAME
3 b's truck & auto plaza
STREET_NUMBER
14749
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
000-027-346-4
CURRENT_STATUS
01
SITE_LOCATION
14749 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of aboveground petroleum storage act violations that <br /> have not been addressed for 3 b ' s truck & auto plaza as of September 09 , 2022 . <br /> Open violations from December 20, 2021 inspection <br /> Violation #619 - Failure to keep written records of procedures , inspections , and tests for at least three <br /> years . <br /> OBSERVATION The facility failed to keep records of inspections for at least three years . The following records <br /> were missing : <br /> - Monthly inspections for all tanks and portable containers were missing from June 2020- December 2020 <br /> - Monthly inspections for the 10 , 000 gallon gasoline , 500 gallon oil , 150 gallon oil , 1000 gallon used oil , four 280 <br /> gallon oil tanks and the portable containers for January 2020 to May 2020 . <br /> -2020 annual inspection for the 500 gallon oil , 150 gallon oil , 1000 gallon used oil , four 280 gallon oil tanks <br /> REGULATION GUIDANCE: 112. 7 (e) Conduct inspections and tests required by this part in accordance with written <br /> procedures that you or the certifying engineer develop for the facility. You must keep these written procedures and a <br /> record of the inspections and tests , signed by the appropriate supervisor or inspector, with the SPCC Plan for a <br /> period of three years . Records of inspections and tests kept under usual and customary business practices will <br /> suffice for purposes of this paragraph . <br /> 112. 8 (c) (6) Test or inspect each aboveground container for integrity on a regular schedule and whenever you make <br /> material repairs . You must determine , in accordance with industry standards , the appropriate qualifications for <br /> personnel performing tests and inspections , the frequency and type of testing and inspections , which take into <br /> account container size , configuration , and design (such as containers that are : shop-built, field -erected , <br /> skid-mounted , elevated , equipped with a liner, double-walled , or partially buried ) . Examples of these integrity tests <br /> include , but are not limited to : visual inspection , hydrostatic testing , radiographic testing , ultrasonic testing , acoustic <br /> emissions testing , or other systems of non -destructive testing . You must keep comparison records , and you must <br /> also inspect the container's supports and foundations . In addition , you must frequently inspect the outside of the <br /> container for signs of deterioration , discharges , or accumulation of oil inside diked areas . Records of inspections <br /> and tests kept under usual and customary business practices satisfy the recordkeeping requirements of this <br /> paragraph . <br /> CORRECTIVE ACTION : Immediately keep written inspection procedures and records of inspections and testing <br /> signed by the appropriate supervisor/inspector for at least three years . Submit proof of correction to the EHD . <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) . <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.