Laserfiche WebLink
DoE-_ SAN AQN Environmental Health Department <br /> N <br /> � - <br /> IT ; , COUNTY Jasjit Kang , RENS , Director <br /> �q4 . P / Greotness grows here . Muniappa Naidu, REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Steven Shih , REHS <br /> Michelle Henry, REHS <br /> Elena Manzo , REHS <br /> October 27 , 2022 <br /> Carrie Miller <br /> Elite IV Contractors <br /> 2535 Wigwam Dr. <br /> Stockton , CA 95205 <br /> carrie (a),eliteiv . com <br /> Re : Shell Food Mart SR00855281 2 "d amendment <br /> 2320 S . EI Dorado St . , Stockton , CA 95204 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST) system at the above <br /> noted address : <br /> • Replace all diesel primary and secondary piping <br /> • Repair the 91 STP sump with a fiberglass repair kit <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department , the San Joaquin Valley Air Pollution Control District , and the <br /> San Joaquin County Community Development Department for any applicable permits and <br /> requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust � sigov . orq to arrange the following appointments ( a 48- hour <br /> notice is required for inspection appointments) . <br /> a . Primary piping test : Soap test of all diesel piping and penetrations ( product , vapor <br /> recovery , vent , and chase) , and one- hour pneumatic pressure test , in accordance with <br /> manufacturer installation instructions . <br /> b . Verification of secondary piping slope at 1 /8 inch per foot or greater, to a containment <br /> sump with an audible and visual alarm . <br /> c . Secondary piping test : Soap test of all diesel piping and penetrations ( product , vapor <br /> recovery , vent , and chase) , and one- hour pressure test at the manufacturer' s <br /> recommended specification . <br /> d . Verification of all pipe setbacks , cross-overs , and burial depth according to the <br /> manufacturer' s installation instructions , and verification of appropriate piping backfill . <br /> e . Witness soil and/or water sampling under diesel piping <br /> f. Since concrete will be broken near the additional piping , UDCs and tanks , a secondary <br /> containment test must be performed on the affected components once concrete is <br /> poured in accordance with the manufacturer' s guidelines . <br /> g . 24- hour hydrostatic test (or equivalent) on the 91 STP sump . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www . sjgov . org/ehd <br />