Laserfiche WebLink
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for A&A GAS & FOOD MART as of Aprill 8 , 2022 . <br /> Open violations from February 15 , 2022 inspection <br /> Violation #106 - Failure to submit and maintain a current facility plot plan / site map . <br /> OBSERVATION An accurate UST Monitoring Site Plan was not submitted . Locations of sensors are not included <br /> on the site map . <br /> REGULATION GUIDANCE: Asite plan must be submitted identifying the locations where monitoring will be <br /> performed. The site plan must show the general layout of tanks and clearly identify locations of the following <br /> equipment, if installed : 1 ) monitoring panels ; 2 ) in -tank liquid level probes ( if used for leak detection ) ; 3 ) devices <br /> monitoring tank annular spaces or vault; 4 ) devices monitoring product piping ; 5) devices monitoring fill piping ; 6 ) <br /> devices monitoring vent piping ; 7 ) devices monitoring vapor recovery piping ; 8 ) devices monitoring vent/transition <br /> sumps ; 9 ) devices monitoring under-dispenser containment; 10 ) line leak detectors ; and 11 ) devices monitoring any <br /> other secondary containment areas . <br /> CORRECTIVE ACTION : Immediately log into the California Environmental Reporting System ( CERS ) at <br /> http : //cers . calepa . ca . gov/ and upload a copy of the UST Monitoring Site Plan . <br /> ❑ This violation was corrected ❑ This violation will be corrected by ( date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #109 - Failure to submit " Designated Underground Storage Tank Operator Identification Form" <br /> within 30 days . <br /> OBSERVATION A new designated operator, Amy Winkler, began conducting inspections on 5/6/2021 and <br /> notification was not provided to the EHD within 30 days of the change . <br /> REGULATION GUIDANCE: The owner or operator shall submit a " Designated Underground Storage Tank Operator <br /> Identification Form " no later than 30 days after any change in the designated UST operator(s) . <br /> CORRECTIVE ACTION : Immediately log into the California Environmental Reporting System ( CERS ) at <br /> http : //cers. calepa . ca . gov and upload the notification identifying all the designated operators for this facility. <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) : <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Page 1 of 1 <br />