COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3425
>
2300 - Underground Storage Tank Program
>
PR0231416
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/6/2022 10:24:25 AM
Creation date
1/24/2022 11:07:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231416
PE
2361
FACILITY_ID
FA0003627
FACILITY_NAME
ARCO 02093
STREET_NUMBER
3425
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418020
CURRENT_STATUS
01
SITE_LOCATION
3425 TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
144
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHEET INDEX <br /> SHEET <br /> 1 SITE PLAN <br /> 2 DETAILS _ <br /> P.I_ = 150.00' <br /> PROJECT DATA <br /> PROJECT NAM ARCO #2093 ab <br /> r <br /> CONTAINER STEEL PIROJECTADDFM: 3425 TRACY BOULEVARD, TRACY, CA 95376 <br /> l \ DRIVEWAY FACL1TY PROPS:17Y <br /> j \ OWNED BP WEST COAST PRODUCTS, LLC <br /> \ 4 CENTERPOINT DRIVE, LA PALMA, CA 90623 <br /> (E) VENT RISERS ii BUJ�K300D6� 2019 CBC: CALIFORNIA BUILDING CODE <br /> o 2019 CMC: CALIFORNIA MECHANICAL CODE <br /> 120119 CPC: CALIFORNIA PLUMBING CODE t <br /> l— — — — 2019 CEC: CALIFORNIA ELECTRICAL CODE ti <br /> 1 2019 CFC: CALIFORNIA FIRE CODE • <br /> ( {) 00 2019 CALIFORNIA HISTORICAL BUILDING CODE <br /> 8 2019 CALIFORNIA BUILDING EFFICIENCY STANDARDS <br /> U <br /> 2018 NFPA 30 <br /> \ � B 201E NFPA 70A <br /> \ D 0 SCOPE OF WORK <br /> -- - - -- A <br /> PLANTER INSTALL TEMPORARY FENCING AROUND WORK AREA. <br /> �\ O <br /> \,\ <br /> MECH. g EXISTING (4) 10,000 GALLON DOUBLE WALL UNDERGROUND STORAGE TANKS AND PIPING SYSTEMS TO REMAIN. <br /> \\\\ <br /> EQUIP. o ' , <br /> �\ D ❑O O AND T AND <br /> AIREMOVE <br /> AN TON OF NEW ESTIMFILL ATED <br /> 7'X7. AREA OF CONCRETE AROUND EACH EXISTING FILL MANWAYS FOR REPLACEMENT <br /> ❑ N Do CUT OR REPLACE EXISTING FILL AND VAPOR RISERS AS NECESSARY FOR NEW OPW SPILL BUCKETS. <br /> (D 0 1I <br /> -i Q (�) FURNISH AND INSTALL NEW FIBRELITE FILL MANWAY EQUIPMENT, THREE (3) @ 87 TANKS AND ONE (1) 0 91 TANK. <br /> �\ a <br /> �\ INSTALL NEW OPW PHASE 1 VAPOR RECOVERY EQUIPMENT AS PER VR-102 EXECUTIVE ORDER., INCLUDING NEW OVERFILL <br /> LLr <br /> �\ Q PREVENTION VALVES AND DROP TUBES. <br /> 0 , © INSTALL MATCHING PRODUCT COLORED LIDS AND SPILL BUCKET ID COLLARS AND TAGS <br /> \ �� W <br /> \-\ j 0 <br /> DOWELL AND REPLACE BACK CONCRETE AT AREA'S OF WORK. <br /> 7u FE] ED ® PERFORM ALL REQUIRED TESTING AND INSPECTIONS FOR COMPLETED SYSTEM. <br /> 0 <br /> \ n M <br /> \ O <br /> \ --- B I D E Q <br /> \\' ! 1 071 1) 0 F G H I DRIVEWAY <br /> ! <br /> 7 <br /> (TYP OF 4) <br /> � II SUP �UN�� UNL �I UN� • <br /> II 91 Il II 87 II li 8� 111 87 11 <br /> II Il 11 I li 11 II 11 GENERAL NOTES <br /> (01I� Iil �I I� �� A 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT APPLICABLE EDITIONS OF THE CALIFORNIA BUILDING CODE, <br /> CALIFORNIA PLUMBING CODE, CALIFORNIA MECHANICAL CODE, CALIFORNIA FIRE CODE, CALIFORNIA ELECTRICAL CODE, <br /> 11 WORK AREA CAL—OSHA CONSTRUCTION SAFETY ORDERS, AND ALL OTHER APPLICABLE STATE, CITY AND COUNTY ORDINANCES. <br /> 2. CONTRACTOR IS RESPONSIBLE FOR CONTACTING UNDERGROUND SERVICE ALERT (USA) 1-800-227-2600 OR 811 AT <br /> \ ❑ LEAST 2 WORKING DAYS PRIOR TO THE START OF WORK <br /> 3. SITE SPECIFIC ARCHITECTURAL AND CIVIL DRAWINGS SHALL TAKE PRECEDENCE FOR REFERENCING ALL DIMENSIONS, <br /> ELEVATIONS AND EQUIPMENT LOCATIONS. <br /> ° PLANTER 4. ALL DIMENSIONS AND CONDITIONS SHALL BE CHECKED AND VERIFIED IN THE FIELD BEFORE BIDDING. ANY DISCREPANCIES <br /> SHALL BE CALLED TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE FOR HIS/HER DECISION PRIOR TO FINALIZING z <br /> BIDS AND START OF WORK. <br /> 5. CONTRACTOR SHALL PROTECT ALL EXISTING FACILITIES, BOTH PUBLIC AND PRIVATE, WHICH ARE TO REMAIN UNLESS � <br /> — PUNTER PLANTER Q� 1 NOTED OTHERWISE. CONTRACTOR SHALL REPAIR OR REPLACE, TO THE OWNER'S SATISFACTION, ANY EXISTING FACILITIES W <br /> ' 0 10 20 40 fid <br /> P.L. 129.98' WHICH ARE DAMAGED AS RESULT OF CONTRACTOR'S OPERATIONS. V <br /> � Q <br /> © 6. ALL WORK AREAS SHALL BE ADEQUATELY BARRICADED THROUGHOUT THE CONSTRUCTION PERIOD. � <br /> DRIVEWAY � DRIVEWAY O SCALE: 1"= 2D' W <br /> F-111p 7. CONTRACTOR SHALL OBTAIN NECESSARY PERMITS FROM APPLICABLE AGENCIES FOR EXCAVATIONS OF TRENCHES 5'-0" OR Q! <br /> MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND. <br /> 8. CONTRACTOR TO PERFORM ALL REQUIRED VAPOR RECOVERY TESTING PER CARB VR-204 AND LOCAL AIR POLLUTION W <br /> SITE PLAN CONTROL AUTHORITY AND FORWARD RESULTS TO OWNER AND JURISDICTION AS SPECIFIED IN THE PERMIT CONDITIONS. m <br /> SCALE: 1 = 20 —0 = LO <br /> 9. ALL MATERIALS SHALL BE COMPATIBLE FOR USE WITH THE INTENDED PURPOSE PER NATIONALLY RECOGNIZED CODES, n <br /> CLOVER ROAD LOCAL CODES AND GOVERNING AUTHORITIES. m }-- t.0V LO <br /> 10. FUELING SYSTEM TO BE INSPECTED PER LOCAL REGULATING AGENCIES AND BY OWNER'S REPRESENTATIVE PRIOR TO Z © �.ry < Cr) <br /> BEING PLACED BACK INTO SERVICE. Z Ck� <br /> ,. J Q © F` Q <br /> 11. TANK SYSTEM, LEAK DETECTORS AND MONITORING SYSTEM INTEGRITY TESTS SHALL BE FORWARDED TO AND APPROVED BY C-4 U <br /> GOVERNING AGENCY PRIOR TO TANK SYSTEM BEING PLACED INTO OPERATION (AS APPLICABLE). Q zh:t Z <br /> 12. NO NEW ELECTRICAL LOADS WILL BE INTRODUCED AS A RESULT OF THIS PROJECT. W Z 0 U <br /> F= c� ESI Q <br /> � <br /> '.� � <br /> BILL OF MATERIALS LEGEND CU/) m , ,` <br /> PART DESCRIPTION QTY. MANUFACTURER—PART NUMBER (E) EXISTING DRAWN BY: MB <br /> O SC—WHITE SEALABLE FILL COVER 4 FIBRELITE (N) NEW REVIEWED BY: LM <br /> DATE: 3.28.2022 <br /> O SC—ORANGE SEALABLE VAPOR COVER 4 FIBRELITE ESO EMERGENCY SHUT—OFF JOB NO: 22100012.1 <br /> O EVR FILL SWIVEL ADAPTOR, BRASS 8 OPW— 634TT-7085—EVVR VICINITY MAP <br /> O FILL CAP, GRAY 8 OPW-634-7085—EVR <br /> Fb:llnlh C'n <br /> I;hrtt.nn I[ <br /> O <br /> 8 FIBRELITE—Ft100GRAY—MP-165 IYlrnl.Nf.�Y ._ lwi crn;ir.,•lkl ,MANHOLE COVER <br /> ® STEPPED SKIRT <br /> 8 FIBRELITE—FL1 00—SK 10-46 <br /> 0 VAPOR CAP—ORANGE 4 OPW-1711T-7085 EVR F <br /> ® SWIVEL ADAPTOR, BRASS <br /> 4 OPW-61 V5A-1020—EVR goea�l r- <br /> M <br /> h!XIAISI3P FWY - .. _ 's Ulam SI 3 r;ka ' <br /> a OVERFILL PREVENTION VALVE WITH DROP TUBE 4 OPW-71—SO <br /> AQMD INFORMATION I.z <br /> Itesl wer cr, I N-pul - wl-o,eflti <br /> IMPORTANT NOTICE M�.e,.l� rylnh 3iaf5 .Yw �I.r, .r, <br /> nnCSvlle.hV •: unWl1 tl '1 Wh fml <br /> R, HMMha Incy MS'Y:.;S- is l4c,dy'; rr <br /> 10 VAPOR SPILL BUCKET 4 DPW—P761C—FLPt Section 4216/4217 of the Government SHEET NO. <br /> Code rewires a Dlg Alert Identification <br /> 11 FILL SPILL BUCKET 4 OPW—P761C—FLDVNumber be issued before a <br /> O <br /> NUMBER OF E FUELING STATIONS 8 Permit to Excavate will be valid U a <br /> 12 JACK SCREW ASSEMBLY NUMBER OF (E) GASOLINE NOZZLES 8 For your Dig Alert ID Number Call S <br /> 4 <br /> DPW-61 JSK-44C8 UNDERGROUND SERVICE ALERT .! !e: Gcerlae an7 <br /> serutr.s I le u.nlal cam. I°W hlse: <br /> NUMBER OF (N) FUELING STATIONS 0 irv,c;l <br /> 13 TOP HAT 4 MANYWAY TOP HAT NUMBER OF (N) GASOLINE NOZZLES o 1 -800-227-2600 x <br /> 1 :an. <br /> 14 MANWAY COVER FRAME 4 FIBRELITE—FL-100F or 811 <br /> NUMBER OF (N) DIESEL NOZZLES 0 For Underground Locating 5; , vitl "°'` SHEET 1 OF 2 <br /> 15 <br /> 2 Working Days before You Dig <br /> SHROUD BOOT WITH BANK CLAMP 4 OPW—FLMP—SB �' <br />
The URL can be used to link to this page
Your browser does not support the video tag.