My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3425
>
2300 - Underground Storage Tank Program
>
PR0231416
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/6/2022 10:24:25 AM
Creation date
1/24/2022 11:07:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231416
PE
2361
FACILITY_ID
FA0003627
FACILITY_NAME
ARCO 02093
STREET_NUMBER
3425
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418020
CURRENT_STATUS
01
SITE_LOCATION
3425 TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
144
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Measure&record"A"and"Z,"and then peform the following calculation: <br /> „A„ 4 Z Drop tube seal surface to the bottom of the tank <br /> -(subtract) <br /> l " Upper d tube flange to tt-.e edge of the uppttr tube adapter <br /> -(subtract) <br /> 4.5" Reference offset <br /> (equals) <br /> lO " Final shutalf volume height <br /> Locate the final shutoff volume <br /> height on the tank chart <br /> Use the tank chart provided by the tank provided by the tank <br /> manufacturer to record and calculate the following manufacturer,and record the <br /> (� <br /> gal <br /> Final shutoff volume closest corresponding volume <br /> (divide by) <br /> t,$Ll Sal Actual tank capaclty <br /> X(muliply by) <br /> 100 <br /> (equals) If the Final shutoff volume <br /> v O percentage is 95%or tess,the <br /> r Q�A Final shutoff volume pereentq; installation conforms t&FFS-and <br /> industry recommended practices <br /> 1pg gal Actual tank capacity <br /> The final Shutoff Volume Percentage may <br /> -(subtract) be greater than 95%as long as the ullage <br /> (S Sal F nal shutoff volume volume remaining Is grrgater than or <br /> _(equals) equal to 250 gallons,so that" none of <br /> p the fillings located on the top of the tank <br /> d 6 gal Ullage volume remaining are exposed to product due to <br /> overfilling,"according to EPA 40 CFR Part <br /> 280 The installation must also meet all <br /> applicable regulatory requirements and <br /> must be acceptab a to the Authority <br /> Having lurisdrcl an IAHlI. <br /> .� 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.