My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL PINAL
>
1325
>
2231-2238 – Tiered Permitting Program
>
PR0543720
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/14/2022 10:37:24 AM
Creation date
1/27/2022 9:41:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2231-2238 – Tiered Permitting Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0543720
PE
2231
FACILITY_ID
FA0024706
FACILITY_NAME
METAL FINISHING SOLUTIONS - STOCKTON CA
STREET_NUMBER
1325
STREET_NAME
EL PINAL
STREET_TYPE
DR
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
1325 EL PINAL DR STE 1
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
149
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Metal Finishing Solutions, Inc. <br /> SELF-MONITORING SAMPLE PROGRAM <br /> The permittee,Metal Finishing Solutions,Inc.,located at 1325 EI Final Drive,shall perform the following self-monitoring <br /> sample program effective October 1,2018,and continuing until the complete expiration of this permit.The permittee shall <br /> perform sample monitoring for the listed pollutant parameters using sample frequencies, sample types, and <br /> methodologies specified in this self monitoring sample program.All handling and preservation of the collected samples <br /> and laboratory analyses of samples shall be performed in accordance with 40 CFR Part 136,and amendments thereto, <br /> unless otherwise specified in the monitoring conditions of this permit. <br /> The permittee shall sample for pollutant parameters at those designated sample location points identified below: <br /> Sample Point Locations <br /> Sample Point No. Sample Point Description <br /> 001 Final Effluent Automatic Sampler <br /> 002 Final Effluent Grab Sample Spigot <br /> 003 Final Effluent Flow Monitor <br /> 004 Final Effluent pH Monitor <br /> Sample Discharge Limit(1)Instantaneous maximum <br /> Pollutant Sample Sample Location <br /> Parameter Frequency Type diagra (2)Dally maximum <br /> (diagram <br /> attached) (3)Monthly maximum <br /> (4)Monthly average <br /> Flow Continuous Metered end 003 130,000 gallons/month-local limit <br /> recorded (3) <br /> 15 gallons/minute-local limit(1) <br /> pH Continuous Metered and 004 5.0-10.0—local limit(1) <br /> recorded <br /> Cadmium,total 1per 6 months 24-hour flow 001 0.11 mg/L-categorical limit(2) <br /> proportional 0.07 mg/L-categorical limit(4) <br /> composite, <br /> representative of <br /> reporting period. <br /> Copper,total 1per 6 months 24-hourflow001 3.38 mg/L-categorical limit(2) <br /> proportional 2.07 mg/L-categorical limit(4) <br /> composite, <br /> representative of <br /> reporting period. <br /> Chromium,total 1per 6 months 24-hour flow 001 2.77 mg/L-categorical limit(2) <br /> proportional 1,71 mg/L-categorical limit(4) <br /> composite, <br /> representative of <br /> reporting period. <br /> Lead,total iper 6 months 24-hourflow 001 0.69 mg/L-categorical limit(2) <br /> proportional 0.43 mg/L-categorical limit(4) <br /> composite, <br /> representative of <br /> reporting period. <br /> Nickel,total 1per 6 months 24-hourflow 001 3.98 mg/L-categorical limit(2) <br /> proportional 2.38 mg/L-categorical limit(4) <br /> composite, <br /> representative of <br /> reporting period. <br /> Zinc,total iper 6 months 24-hour flow 001 2.61 mg/L-categorical limit(2) <br /> proportional 1.48 mg/L-categorical limit(4) <br /> composite, <br /> representative of <br /> reporting periotl. <br />
The URL can be used to link to this page