My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
ESCALON
>
1329
>
2300 - Underground Storage Tank Program
>
PR0231487
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2023 8:21:50 AM
Creation date
1/31/2022 8:47:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0231487
PE
2351
FACILITY_ID
FA0000293
FACILITY_NAME
Pershing Holdings, Inc. DBA Esclon Arco
STREET_NUMBER
1329
STREET_NAME
ESCALON
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22510003
CURRENT_STATUS
01
SITE_LOCATION
1329 Escalon Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN:JOAQUiN <br /> Environmental Health Department <br />COUNT Y- <br />Underground Storage Tank Program inspection Report <br />Facility Name: <br />Pershing Holdings, Inc. DBA Esclon Arco <br />Facility Address: <br />11329 Escalon Ave, Escalon <br />Date: <br />February 17, 2022 <br />UST System Observations <br />312 HSC 25290.2(d) Monitoring system incapable of detecting entry into secondary containment (Jul 2003-Jun 2004) oV OR COS <br />313 HSC 25290.1(d) Monitoring system Incapable of detecting entry into secondary containment (post-Jul 2004) oV oR oCOS <br />314 CCR 2631(g), 2632(c) <br />(2) <br />Failure to continuously monitor interstitial space with audible-visual alarm system (pre-Jul 2004) oV oR a COS <br />315 HSC 25290.1(e) Failure to maintain interstitial space to detect leaks before release to environment (post-Jul 2004) oV oR oCOS <br />316 CCR 2636, 2643(c)(1), <br />2666(f) <br />Failure to install a line leak detector oV oR oCOS <br />317 CCR 2636(f)(2) Failure of the line leak detector to detect a 3.0 gph leak at 10 psi and restrict or shut off flow oV oR oCOS <br />318 CCR 2635, 2637.1, <br />2665, 2712 <br />Failed to meet spill container requirements oV oR oCOS <br />319 CCR 2635, 2637.2, <br />2665, 2712 <br />Failure to comply with overfill prevention equipment requirements oV oR COS <br />320 CCR 2635(c)(1) Overfill prevention was overridden oV oR COS <br />321 HSC 25299(a)(9) Leak detection equipment disabled or tampered with oV oR oCOS <br />322 CCR 2717.1(g) Removed, defaced, altered, or otherwise tampered with red tag oV oR oCOS <br />323 CCR 2717.1(f); HSC <br />25292.3(c) <br />Deposited or allowed deposit of petroleum or a hazardous substance into a red tagged UST oV oR oCOS <br />324 HSC 25292.3(c)(1)(C) Allowed dispensing from a UST that has a red tag affixed to the fill pipe oV oR COS <br />325 CCR 2635, 2636(b), <br />2662, 2712 <br />Failure to comply with the cathodic protection system requirements oV oR oCOS <br />326 CCR 2631(b&d), <br />2666(b&e) <br />Primary and/or secondary containment not constructed in accordance with the established standards oV oR aCOS <br />327 CCR 2638(a), 2641(j) Leak detection equipment not installed/calibrated/operated/maintained per manufacturer instructions oV aR COS <br />328 CCR 2630, 2632, 2643, <br />2644.1 <br />Equipment or methods used to monitor the UST system are not certified by an independent third-party oV oR oCOS <br />329 CCR 2631.1, 2660(m) UST system not compatible with the substance stored oV oR oCOS <br />330 CCR 2636(f), 2666(c), <br />2666(f) <br />Failure of emergency generator line leak detector to restrict or shut off flow or trigger an alarm V oR oCOS <br />331 HSC 25281.6(a) Failure of unburied below-grade emergency generator system to meet exemption conditions oV oR COS <br />332 HSC 25283.5(a) Failure of unburied below-grade UST system to meet exemption conditions oV oR a COS <br />333 CCR 2666(b)(2) Failure to upgrade single-walled pipe to double-walled interstitially monitored pipe when repaired oV oR oCOS <br />334 CCR 2670(b)(e)(f), <br />2671 <br />Failure to comply with temporary closure requirements oV oR COS <br />335 HSC 25298(c); CCR <br />2670, 2672 <br />Failure to comply with all permanent closure requirements oV oR oCOS <br />336 CCR 2638(f), 2641(j) Failure to affix a tag/sticker on each monitoring equipment certified, repaired, or replaced V R a COS <br />Single-Walled Non-Pressurized Piping <br />401 CCR 2636(a)(3), <br />2641(b) <br />Safe suction piping not properly sloped or check valve incorrectly located oV oR oCOS <br />402 CCR 2643(d) Failure to conduct monitoring and maintain records for single-walled conventional suction (pre-1984) oV oR oCOS <br />403 CCR 2643(d), 2661(f) Failure to conduct 0.1 gph integrity test for single-walled conventional suction systems (pre-1984) oV oR oCOS <br />404 CCR 2643(e), 2661(f) Failure to conduct 0.1 gph test on single-walled gravity piping biennially or post repair (pre-1984) oV oR oCOS <br />i <br />FA0000293 PR0231487 SC001 02/17/2022 <br />EFID 23-01 Rev. 12/06/2021 Page 3 of 4 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 I T 209 468-3420 I F 209 464-0138 I www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.