My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SR0084482
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HANSEN
>
26955
>
4200/4300 - Liquid Waste/Water Well Permits
>
SR0084482
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2022 4:47:35 PM
Creation date
2/1/2022 3:10:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
SR0084482
PE
4222
FACILITY_NAME
26955 S HANSEN RD
STREET_NUMBER
26955
Direction
S
STREET_NAME
HANSEN
STREET_TYPE
RD
City
TRACY
Zip
95377
APN
20911009
ENTERED_DATE
11/15/2021 12:00:00 AM
SITE_LOCATION
26955 S HANSEN RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
°p`Nc SAN JOAQUIN <br />COUNTY <br />kq�/F Greatness grows here. <br />Environmental Health Department <br />PERCOLATION TEST/SOIL PROFILE INSPECTION CHECKLIST <br />SJC Ordinance Code, Title 9, Section 9-1105.2 <br />EHD Policy for Percolation Test Procedure 98-01 <br />Site Location: Z 9 A ih Se 1 YC, c <br />Date: <br />2 <br />Test Performed by: I Sick I Permit#: jS:gouVVqFLj <br />PAM <br />SITE MAP <br />/ \ <br />Includes perc test and soil profile locations with accurate measurements from a fixed reference point (must be able to locate <br />the test hole areas in the future). Perc/soil profile holes must meet distance setbacks as noted in the sewage standards for <br />septic system locations. Percolation test holes and soil profile pits must be conducted in the area proposed for future septic <br />systems. <br />Notes any changes in elevation on the subject property. <br />Notes all water wells. <br />Notes all man-made features (septic sstems, drives, barns, outbuildings, animal pens, etc. <br />Notes all natural features (ephemeral drainage courses, large stands of trees, ponds, rivers, etc. <br />PERC TEST PREPARATION PROTOCOL <br />Date and time of test hole preparation. <br />Diameter and depth of test hole W-1 diameter and 36"- 2'` epth . <br />Dimensions and depth of deep test hole 4)12" diameter and "-25' or minimum 10' above seasonal high water table). <br />Test hole preparation(scoring of sidewalls, removal of loose material). <br />Weather conditions at time of testing (raining, windy, etc. V ev ^T <br />Soil type and condition encountered in test hole. <br />Addition of 2" of course sand or fine gravel to test hole. <br />Pre-soak by addition of minimum 12" of water over gravel 24 -hours before test). <br />PERC TEST CONDITIONS, MEASUREMENTS, AND REPORTING <br />Condition of test hole after the 24-hour re -soak amount of water remaining in the hole, any soil sloughing noted). <br />Correct amount of water used to refill hole 6" over gravel). Documented on the recordation sheet. <br />Description oft pe of perc test procedure used based on conditions Procedure #1, #2, or #3). <br />Accurate recordings of drop and refill of water in same measurements. <br />Same fixed reference point used for each reading. Description of reference point used to be included in the final report. <br />Math calculations checked for accuracy, <br />Beginning and end measurements of the last reading verified by REHS. All above reviewed and verified by REHS. <br />SOIL PROFILE <br />Description of the date, time, and protocol used to prepare soil profile pit. <br />Description of soil profile pit including depth and dimensions. <br />Soil lithology described by appropriate professional using industry standard protocol, <br />COMMENTS <br />REHS Name: <br />Calculations Examples. <br />Last drop reading = .07' over 30 minutes time. <br />.07'x 12" = .84" (convert from feet to inches) <br />30 minutes = .84" = 35.7 minutes/inch <br />Last drop reading = 1.2' over 10 minutes time. <br />1.2' x 12" = 14.4" (convert from feet to inches) <br />10 minutes _ 14.4" = .69 minutes/inch <br />EHD 4200-xx 8-1-2018 <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.