Laserfiche WebLink
S Q N AQN Environmental Health Department <br /> - <br /> "i ' COUNTY Jasjit Kang , REHS , Director <br /> c PMuniappa Naidu, REHS, Assistant Director <br /> IFF 0+ <br /> Greatness grows here . <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Steven Shih , REHS <br /> Michelle Henry , REHS <br /> June 29 , 2022 Elena Manzo , REHS <br /> STEFANIE CROWE <br /> TANK-TIGHT SYSTEMS , INC <br /> 8515 WATERMAN RD <br /> ELK GROVE , CA 95624 <br /> Re : SAVE ON GAS SR0085370 <br /> 420 W YOSEMITE AVE , MANTECA , CA 95337 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of the <br /> application for a permit to do the following on the underground storage tank ( UST) system at the above <br /> noted address : <br /> • replace the direct- bury 87 spill container <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust slgov . org to arrange the following inspection appointments <br /> ( a 4 & hour notice is required for inspection appointments ) . <br /> a . Corrosion protection : Verify corrosion protection for direct bury spill bucket prior to <br /> backfilling . <br /> b . Spill bucket test : Verify minimum 5-gallon capacity and pass a one hour hydrostatic test ( or <br /> equivalent) , after concrete is set . Proper drainage must also be verified . <br /> c . Since concrete will be broken near the 87 tank , a secondary containment test must be <br /> performed on the 87 tank once concrete is poured in accordance with the manufacturer' s <br /> guidelines . <br /> Please be aware that the facility cannot receive fuel in the 87 tank prior to the EHD inspection <br /> and approval . <br /> 4 . Individuals installing underground storage tank system components must possess or work <br /> under the direct and personal supervision of an individual physically present at the work site <br /> who possesses all of the following : <br /> a . A valid , current contractor' s license issued by the Contractors State License Board <br /> b . A valid , current UST Installation / Retrofitting certificate issued by the International Code <br /> Council ( ICC ) .' <br /> c . A valid , current certificate of training from the manufacturer(s ) of the component (s) being <br /> installed <br /> 1868 E . Hazelton Avenue Stockton , California 95205 T 209 468-3420 F 209 464-0138 1 www. sjgov . org/ehd <br />