My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1330
>
2300 - Underground Storage Tank Program
>
PR0515864
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2023 9:28:57 AM
Creation date
2/2/2022 1:48:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0515864
PE
2361
FACILITY_ID
FA0012355
FACILITY_NAME
A&A GAS FOOD MART
STREET_NUMBER
1330
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
22120053
CURRENT_STATUS
01
SITE_LOCATION
1330 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Received <br /> 11/18/2022 <br /> SAN 10 AQU I N Environmental Health Department <br /> —COUNTY <br /> Greocriess <br /> —C4UNTYGreotness grows here. <br /> Underground Storage Tank Program Inspection Report <br /> Faclllty Name: Facility Phone: Date: <br /> A&A GAS FOOD MART (209)825-0332 November 18,2022 <br /> Facility Address: CERS ID: <br /> 1330 E YOSEMITE AVE,MANTECA,CA 95336 10184191 <br /> Inspection Contact: Title: Phone: <br /> Ghulam Ali Operator (510)396-5560 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 2361 -UST FACILITY <br /> Consent For: Consent Given By: <br /> FxJ Inspection ❑x Photos ❑Samples Roshal Dhillon,Cashier <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp,Date: <br /> Edward Stearns 11/05/2024 David Winkler 02/17/2024 <br /> Service Technician Manufacturer's Training: <br /> VR,07/31/23;VMI,05/27/23;FF,11/28/24 <br /> CCR=Title 23 California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations EHD=Environmental Health Department <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br />}y, 101 HSC 25284;CCR Failure to obtain a permit to operate from the EHD including but not limited to unpaid permit fees ❑V ❑R ❑COS <br /> 2711(d) <br /> ri <br /> 102 CCR 2711 Failure to submit a complete and accurate application for a permit to operate a UST ❑V ❑R 13 COS <br />•Ir <br /> V 103 CCR 2635(f),2636(c)(2) Failure to submit the UST Certification of Installation/Modification o V o R o COS <br /> 0 104 CCR 2632(d)(1),2634(d) Failure to submit a complete and accurate UST Monitoring Plan ■V ■R o COS <br /> 105 CCR 2632(d)(2),2634(e) Failure to submit a complete and accurate UST Response Plan o V ❑R o COS <br /> 106 CCR 2632(d),2641(h) Failure to submit and maintain a current facility plot plan/site map c V o R o COS <br /> 107 HSC 25292.2;CCR Failure to submit and maintain complete and current financial responsibility documents ■V ■R o COS <br /> ` , i• 2711(a)(11) <br /> 108 CCR 2620(b);HSC Failure to implement or maintain a written agreement between the UST owner and operator o V o R ❑COS <br /> 25284(a)(3) <br /> 109 1 CCR 2715(.)(1)(6), Failure to submit"Designated Underground Storage Tank Operator Identification Form"within 30 days ■V ■R ❑COS <br /> 2715(a)(3) <br /> 110 CCR 2715(a)(1)(A), Failure to submit the"Underground Storage Tank Statement of Understanding and Compliance Form" o V o R o COS <br /> 2715(a)(2) <br /> 111 CCR 2637,2638(e), Failed to notify the EHD 48 hours prior to conducting testing o V o R o COS <br /> 2643(g) <br /> 112 CCR 2638,26410), Failure to have properly qualified service technician test leak detection equipment every 12 months o V o R o COS <br /> 2715(f) <br /> \ 113 CCR 2637(.-1),2712(b) Failure to conduct secondary containment testing o V o R o COS <br /> (1)(F) <br /> 114 CCR 2636(f)(3),2643(c) Failure to perform line integrity test every 12 months or within 30 days of repair of primary pipe o V o R o COS <br /> 115 CCR 2638(c),2638(d) Failure to submit"Monitoring System Certification Form"within 30 days of completion of the test u V o R o COS <br /> 116 JCCR 2637.1(d), Failure to submit the"Spill Container Testing Report Form"within 30 days o V o R o COS <br /> 2637.1(e) <br /> s <br /> 117 CCR 2637(.),2637(Q Failed to submit"Secondary Containment Testing Report Form"within 30 days after the test o V o R c COS <br /> o <br /> 118 CCR 2637.2(d&e), Failure to submit the"Overfill Prevention Equipment Inspection Report Form"within 30 days ■V ■R o COS <br /> 2665(.&b) <br /> 119 CCR 2663, 2712(b)(6) Failure to comply with tank lining certification,testing,inspection,and record requirements o V o R o COS <br /> 120 CCR 2631,2640.1, Failure to submit and/or maintain documentation regarding compatibility for UST system components o V c R o COS <br /> 2665,2711 <br /> FA0012355 PRO515864 Sc001 11/18/2022 <br /> EHD 23-01 Rev.12/06/2021 Page 1 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue Stockton, California 95205 i T 209 468-3420 1 F 209 464-0138 i www.Sjg0v.org/EHD <br /> �I <br />
The URL can be used to link to this page
Your browser does not support the video tag.