�. 1-4-1- Is. <br /> SAN 10 A Q U I N Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> A&A GAS FOOD MART 1 1330 E YOSEMITE AVE, MANTECA November 18, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 208 CCR 2716(a-e) Failure to comply with the designated operator inspection requirements. <br /> OBSERVATION: The designated operator failed to check and note the correct test dates for the overfill prevention <br /> equipment inspection on the designated operator inspection reports. <br /> -The overfill prevention equipment inspection for the diesel tank was conducted on 1/8/2021. <br /> -The overfill prevention equipment inspection for the 87and 91 tanks were conducted on 11/17/2021. <br /> REGULATION GUIDANCE: During the inspection,the designated operator shall check that all required testing and <br /> maintenance for the UST system have been completed and document the dates they were done. <br /> CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are including all of <br /> the required information on the reports. . , II 'n^ � ,�� <br /> `I t,,_i, 11 h�� � -�d rOl�t l C/J�' <br /> This is a repeat violation, Class II. <br /> �5. k�I�_�( 2-2-- <br /> 304 CCR 2631(a); HSC 25290.1(c) Failure to construct, operate, and maintain primary containment as product-tight. <br /> OBSERVATION: Large amount of oily residue was observed in UDC 9/10, indicating a leak in the primary <br /> containment. <br /> REGULATION GUIDANCE: All primary containment for the UST system must be product tight. <br /> CORRECTIVE ACTION: Immediately have a properly licensed,trained, and certified contractor repair or replace <br /> the failed component(s), under permit and inspection of the EHD if necessary. <br /> This was corrected on site. <br /> This is a repeat violation, Class ll. <br /> 306 HSC 25291(e) Failure to remove, analyze,and properly dispose of water in secondary containment(pre-Jul 2003). <br /> OBSERVATION:Approximately 3 cups of liquid was observed in the diesel fill sump. <br /> REGULATION GUIDANCE: If water could enter into the secondary containment by precipitation or infiltration, it <br /> must be removed and disposed of properly. <br /> CORRECTIVE ACTION:The service technician removed all liquid from the diesel fill sump. Ensure that all sumps <br /> and annular spaces are maintained free of liquid. <br /> This was corrected on site. <br /> This is a repeat violation, Class ll. <br /> FA0012355 PR0515864 SC001 11/18/2022 <br /> END 2101 Rev 12/06/2021 Page 6 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />