Laserfiche WebLink
6'-0" MAX, TYP. <br /> I I GC TO PROVIDE 2" MIN <br /> PLASTIC GROMMET <br /> + + + + + + + + ` <br /> (2)#10 X 1.5" VO <br /> WOOD SCREWS, `1�v <br /> TYP. <br /> �`O� 1/2" GYP BD <br /> PENDANT LIGHT FIXTURE ©2020 STARBUCKS COFFEE COMPANY <br /> SUPPORT OR SIMILAR <br /> SUPPORT <br /> STARBUCKS' <br /> (E) (E) ROOF <br /> ROOF �`ci� 2401 UTAH AVENUE SOUTH <br /> FRAMING FRAMING P PENDANT LIGHT FIXTURE OR SEATTLE, WASHINGTON 98134 <br /> 4"X 18 GA. STEEL BRACING ��� SIMILAR PENETRATION (206) 318-1575 <br /> AT 48" O.C. (PROVIDE CONT. <br /> BRIDGING W/2410 SCREW TO <br /> EA. BRACE WHEN BRACE IS THESE DRAWINGS AND THE PROJECT MANUAL <br /> MORE THAN 12'-0" IN LENGTH). ARE CONFIDENTIAL AND SHALL REMAIN THE <br /> SOLE PROPERTY OF STARBUCKS <br /> CORPORATION, WHICH IS THE OWNER OF THE <br /> COPYRIGHT IN THIS WORK. THEY SHALL NOT <br /> REPRODUCEDBE USEDI <br /> 4"X 18 GA. STEEL <br /> PLASTIC GROMMET SHARED WITH THIRD PARTIES OR IN ANY <br /> 4"X 18 GA. STEEL BRACING 3 MANNER ON OTHER PROJECTS OR <br /> AT 48" O.C. (PROVIDE CONT. STUDS @ 16" OC scale: 1/4"= 1'-0" <br /> W/4#10 SCREWS EXTENSIONS TO THIS PROJECT WITHOUT THE <br /> BRIDGING W/2410 SCREW TO TO (E)JOISTS. 5/8" GYP. BD, TYP PRIOR WRITTEN CONSENT OF STARBUCKS <br /> EA. BRACE WHEN BRACE IS CORPORATION. THESE DRAWINGS AND <br /> MORE THAN 12'-0" IN LENGTH). TWO (2) NO. 12 GAUGE WIRES MUST BE LATERAL FORCE BRACING MEMBERS MUST BE SPECIFICATIONS ARE INTENDED TO EXPRESS <br /> SECURED FROM LIGHT& MECHANICAL SPACED A MIN OF 6" FROM ALL HORIZONTAL DESIGN INTENT FOR A PROTOTYPICAL <br /> FIXTURES AT OPPOSING CORNERS __ PIPING OR DUCT WORK THAT IS NOT PROVIDED <br /> STARBUCKS STORE (WHICH IS SUBJECT TO <br /> ALONG THE FIXTURE'S DIAGONAL. W/BRACING RESTRAINTS FOR HORIZ FORCES. CHANGE AT ANYTIME)AND DO NOT REFLECT <br /> WIRES MAY BE SLACK. BRACING WIRES MUST BE ATTACHED TO THE ACTUAL SITE CONDITIONS. NEITHER PARTY <br /> GRID &TO THE STRUCTURE IN SUCH A MANNER SHALL HAVE ANY OBLIGATION NOR LIABILITY TO <br /> NOTE: -----_-------------- jib- <br /> THAT THEY CAN SUPPORT A DESIGN LOAD OF THE OTHER (EXCEPT STATED ABOVE) UNTIL A <br /> FOUR NO. 12 GAUGE WIRES MUST BE NOT LESS THAN 200 POUNDS OR THE ACTUAL WRITTEN AGREEMENT IS FULLY EXECUTED BY <br /> SECURED TO THE MAIN RUNNER WITHIN 2" LOAD, WHICHEVER IS GREATER, WITH A SAFETY BOTH PARTIES. <br /> 4"X 18 GA. STEEL BRACING OF THE CROSS RUNNER INTERSECTION FACTOR OF 2. <br /> AT 48" O.C. (PROVIDE CONT. AND SPLAYED 90 DEGREES FROM EACH STARBUCKS TEMPLATE VERSION: i2020-01-31.1 <br /> 4"X 18 GA LEDGER + 4"X 18 GA BRIDGING W/2-#10 SCREW TO + 4"X 18 GA OTHER AT AN ANGLE NOT EXCEEDING 45 <br /> W/(2)#10 X LONG + BLOCKING, TYP EA. BRACE WHEN BRACE IS + BLOCKING, TYP DEGREES FROM THE PLANE OF THE LIGHT FIXTURE <br /> WOOD SCREWS AT + MORE THAN 12'-0" IN LENGTH). + CEILING. (MAY BE SLACK) (LESS THAN 56 LBS) <br /> EACH (E) STUD, TYP. ARCHITECT OF RECORD <br /> NO. 12 GAUGE -------- <br /> U <br /> �_ _� � � • <br /> WIRES WITHIN 3" OF - <br /> ---- <br /> ---------- <br /> > o - <br /> - -3" MAX °' <br /> ALL 4 CORNERS. U- " <br /> PROVIDE MINIMUM OF 2 SCREWS AT <br /> OPPOSITE CORNERS OF SUPPORT - <br /> WIRES, OR SCREW ON T-BAR � NOTE: <br /> #10 SMS AT EACH 4 #10 SMS. — 4"X 18 GA. STEEL STUDS AT 16" SAFETY CLIPS E SIDES-B ENDS. PROVIDE EARTHQUAKE m c g a r c h i t e c u re <br /> ( ) O.C. WITH 4 -#10 SCREWS, TYP CLIPS &WIRES AS REQ'D. 1 35 Alton Parkway, Suite 1 Irvin A 2 18 <br /> SIDE AND EACH STUD. TYP. 56 o y, Su 00, e,C 9 6 <br /> SEE 1/I-1107 FOR � <br /> 5/8" GYP. BD, TYP HEIGHT OF SOFFIT P: 949.553.1117 F: 949.474.7056 <br /> SUSPENDED <br /> CEILING GRID ARCHITECT STAMP <br /> USED A Cy <br /> SOFFIT DETAIL CEILING LIGHT DETAIL P�EWiN�` %. <br /> Scale: 1 1/2"= V-0" Scale: 3/8" = V-0" -11839 <br /> VERTICAL STRUT @ 12" O.C. MAX. EACH COMPRESSION STRUT GUIDELINES 9j` tiP <br /> WAY WITH FIRST POINT TO BE WITHIN 6" NOTE: <br /> FROM EACH WALL FASTENED TO MAIN 8 GA HANGER WIRE TO VERIFY ASSEMBLY WITH TRUSS COMPRESSION STRUT SIZE MAXIMUM LENGTH F CALIFO <br /> RUNNER & STRUCTURE ABOVE @ 4'-0" \ MFG WHERE 1 HR ASSEMBLY IS <br /> STRUCTURE ABOVE PER ASCE-7 13.5.6.2.2 OC NW/4 WIRES SPLAYED 90 REQ'D 3/4" DIAMETER STRUT 12'-0" <br /> deg IN 4 DIRECTIONS (45° <br /> o XQ MAX FROM CEILING PLANE) 1" DIAMETER STRUT 18'-0" <br /> 12 GA. VERTICAL cfl SINGLE 2 1/2"x 20 GAUGE METAL STUD (I MIN. = 0.18") 11'-6" <br /> HANGER WIRE AT 4'-0" 900 90° TYPE "S" SCREW <br /> EACH ♦ t # 2'-0" @ 8" OC BACK-TO-BACK 2 1/2"x 20 GAUGE METAL STUD SCREWED 15'-0" <br /> WAY WITH MIN. 3 TIGHT MAX TOGETHER @ 24" O.C. <br /> TURNS 1-1/2"AT BOTH <br /> 20 GAUGE <br /> ENDS OF WIRE (TYP.) FURRING @ <br /> o HEAVY DUTY T-BAR SYSTEM 12 GA WIRE HANGER PER ASTM AC 635 &ASTM AC <br /> 48" O.C. <br /> CHANNEL @ <br /> E - <br /> 24" OC <br /> 636. SEC 1613.1 CBC. EA. WAY. FIRST POINT TO BE 8" <br /> cin CROSS RUNNERS FROM WALL. Q <br /> VERTICAL COMPRESSION STRUT > �/ <br /> o AND BRACING WIRES @ 12'-0" O.C. <br /> MAX. EACH WAY. FIRST POINT TO LU <br /> a fi fi fi o i BE WITHIN 6'-0" FROM EACH WALL. 2 CV <br /> U o srs° FASTENER TO MAIN RUNNER& ,max <br /> 20 GAUGE WIRE ° I �Lj STRUCTURE ABOVE WITH 1/4" W < (V <br /> rn 2 �� \�" MACHINE BOLTS. SEE NOTE 4. z <br /> 06 MAIN RUNNERS — — — t — — — 0 1-1/2"20 GAUGE I 2" MAX. FROM BRACING <br /> N COLD ROLLED I J <br /> 111 8" MAX STEEL @ 48" OC I WIRES TO CROSS TEES w � Q <br /> 75 12 GA. BRACING WIRE WITH MIN. <br /> 4 TIGHT TURNS IN 1-1/2"AT 2 BRACING WIRES TO BE ATTACHED W � LL <br /> BOTH ENDS OF WIRE (TYP.)AT <br /> - 6'-0" 12'-0"OC 5/8" FIRE-RATED �. @ MAX OF 45 DEGREES. MIN OF 4 <br /> W � 10 or GYP, ALL EDGES TIGHT TURNS IN 1-1/2" @BOTH Q <br /> EACH VERTICAL STRUT MAXSUPPORTED ENDS OF ALL BRACING WIRE TYP. z Q O7 0 <br /> Q 75 AT TWO ADJACENT GYPSUM BOARD DETAIL x `� Q ~ ~ <br /> m NOTES: WALLS. SEE NOTE 2 `t g U U O Q <br /> 5 MAIN RUNNER @ 4'-0" O.C. W W CO <br /> ~ REFLECTED CEILING PLAN scale: 1/4"= 1'-0" <br /> m 1. SUSPENDED ACOUSTICAL CEILING SYSTEM SHALL BE O O O O <br /> U) INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF SHIM AS NEEDED LARR#2576 w <br /> I ASTM C 635 AND ASTM C 636. ICC ER#122 <br /> rn <br /> O LINE OF WALL CROSS TEE @ 2'-0" O.C. <br /> O 2. BRACING WIRES SECURED TO MAIN RUNNERS WITHIN 2" OF <br /> 6'-0" MAX.- 6'-0" MAX. OR 1'-0" O.C. AS SHOWN STORE #: 65246 <br /> O <br /> N THE CROSS RUNNER INTERSECTION AND SPLAYED 90° FROM 12'-0" MAX. 12'-0" MAX. ATTACHMENT CLIP NOTES: <br /> 4 EACH OTHER AT AN ANGLE NOT EXCEEDING 45° FROM THE ATTACHMENT #: 88584-001 <br /> N PLANE OF THE CEILING 1. ALL 24"X48" CEILING LIGHT FIXTURES &24"X24" HVAC AIR REGISTERS SHALL BE o CD 1-29-21 <br /> 8" MAX 8" MAX <br /> E � MAIN T-GRID USG SUPPORTED BYA MINIMUM OF (2) HANGERS @OPPOSITE CORNERS. CEILING SYSTEMS ALL ISSUE DATE: 50% <br /> 3. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF ( NOT SUPPORT OTHER ITEMS. DESIGN MANAGER: J. RAMOS <br /> v ,THE CEILING GRID SHALL BE ATTACHED TO A MINIMUM 2"WIDE DX26PRODUCTION DESIGNER: <br /> CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL `U BLACK COLOR) 2. ALL INTERIOR WALL& CEILING FINISHES SHALL BE INSTALLED TO CLASS III FLAME SPREAD.Q w w CHECKED BY: SKIM <br /> DIRECTION SHALL HAVE 0.75" CLEARANCE FROM THE WALL AND w � NO. 12 GA MIN <br /> V SHALL REST UPON AND BE FREE TO SLIDE ON A CLOSURE Oz VERTICAL HANGER 3. 45 DEGREE BRACE WIRES &COMPRESSION STUDS ARE TO BE PROVIDED ONLY IF <br /> U) ANGLE. WIRE, SEE NOTE 3 REQUIRED BY LOCAL BUILDING DEPARTMENT. Revision Schedule <br /> N 4. WHEN THE DISTANCE BETWEEN THE STRUCTURAL DECK AND = '� '� O O 4. COMPRESSION STRUTS : STEEL SECTION ATTACH TO MAIN RUNNERS WITH 1/4" MACH114E Rev Date By Description <br /> THE CEILING EXCEEDS 4", THE SPACING OF THE VERTICAL 0 ACOUSTICAL TILE BOLT AND TO STRUCTURE WITH 3/16" DIAMETER POWER DRIVEN STUD. COMPRESSIONS RUT <br /> HANGERS SHALL NOT EXCEED 2' O.C. ALONG THE ENTIRE MEANS = CEILING ON SUSPENDED .75"AT TWO SHALL NOT REPLACE HANGER WIRE. <br /> U OF EGRESS SERVICING THE OCCUPANT LOAD OF 30 OR MORE, GRID SYSTEM ADJACENT WALLS <br /> AND AT LOBBIES ACCESSORY TO GROUP A OCCUPANCIES. = SEE NOTE 2 5. BRACING WIRES SECURED TO MAIN RUNNERS WITHIN 2" OF THE CROSS RUNNER <br /> COMPRESSION STRUT CEILING PANEL INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT AN ANGLE NOT EXCEE ING <br /> 5. EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATER z 45 DEGREES FROM THE PLANE OF THE CEILING. <br /> 73 DEFLECTIONS, SPRINKLER HEADS AND OTHER PENETRATIONS, E: <br /> 2" MIN WALL ANGLE <br /> Q SHOW A 2" OVERSIZED RING, SLEEVE OR ADAPTER THROUGH (INSTALLED 1/4" BELOW MAIN 6. CLOSURE ANGLE SHALL BE A MINIMUM OF 2". SHEET TITLE: <br /> THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST GRID) CEILING DETAILS <br /> 1" IN ALL HORIZONTAL DIRECTIONS. ALTERNATIVELY SWING 7. THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT LESS T AN <br /> JOINT THAT CAN ACCOMMODATE 1" OF CEILING MOVEMENT IN SECTION THROUGH ROOM PROVIDE COMPLETE 2" IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE CEILING GRID SHALL BE <br /> O ALL HORIZONTAL DIRECTIONS IS PERMITTED TO BE PROVIDED AT INSTALLATION AS RECOMMENDED ATTACHED TO THE CLOSURE ANGLE. THE OTHER END IN EACH HORIZONTAL DIRECTION <br /> THE TOP OF THE SPRINKLER HEAD EXTENSION. PER ASCE 7-05, BY MANUFACTURER AND CODES SHALL HAVE A 0.75" CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TD SCALE: AS SHOWN <br /> j SEC 13.5.6.2.2. SLIDE ON A CLOSURE ANGLE. <br /> O SHEET NUMBER: <br /> N <br /> It 13 TYPICAL SUSPENDED CEILING VERTICAL & LATERAL SUPPORT 46 T-BAR TO WALL DETAIL 1 , T-BAR CEILING DETAIL 1505 <br /> N Scale: 1/8"= V-0" Scale: 6" = 1'-0" scale: 1/4" = 1'-0" <br />