Laserfiche WebLink
SA N 10 A Q U I N Environmental Health Department <br /> COUNTY <br /> I . MONITORING : All monitoring equipment must be listed in the State Water Resources Control Board <br /> Division of Clean Water Program Local Guidance Letter 113 . <br /> Check Code <br /> Box Section <br /> All secondary containment units (e . g , tank annular spaces , secondary piping , sumps , <br /> 23 CCR <br /> under-dispenser containment, etc . ) monitored for leaks using approved electronic leak <br /> 2636 (f) detection systems . <br /> Electronic monitoring sensors located at the following points : <br /> ° At the bottom of the interstitial space of each secondarily-contained tank , <br /> positioned as near as possible to the bottom of the tank . <br /> Manufacturer <br /> Veeter Root Model 794 -380 -303 <br /> ° In each collection sump , positioned as near as possible to the bottom of the <br /> collection sump . Additionally, in any sump acting as secondary containment for <br /> unused tank openings which connect to the primary space . <br /> 794 -380-208 ( Liquid Sensor) <br /> Manufacturer Veeter Root Model 794-380-304 ( Hydrostatic Sensor) <br /> 23 CCR <br /> X❑ ❑ 2632 <br /> 2630 (d ) ° In dispenser pans which do not drain into secondary containment piping . (Note: <br /> A mechanical switch which triggers a shear valve may be substituted but this <br /> system will not qualify for the annual line tightness test exemption under 23 CCR <br /> 2636(g)) , <br /> Manufacturer Veeter Root Model 794 -380-208 <br /> ❑ Along secondarily-contained pipe runs which do not meet the 1 /8 inch - per-foot <br /> slope requirement, positioned in the depressed or low-lying areas . <br /> Manufacturer Model <br /> 23 CCR Automatic line leak detectors installed to monitor underground pressurized piping . <br /> 2636(f) Veeter Root 848480-001 <br /> ❑ HSC Manufacturer Model <br /> 25290. 1 h <br /> 25290. 2 <br /> Alarm panel provides both audible and visual alarms . It is located in a protected area <br /> ❑ 23 CCR and within sight and hearing distance of on -site personnel and hard -wired to a <br /> ❑ 2632(c) (2 )(B) dedicated circuit . <br /> Existing Veeter Root System <br /> Manufacturer Model TLS - 350 <br /> J . OTHER COMPONENT INFORMATION . <br /> COMPONENT IFMANUFACTURER MODEL [ COMPOSITION <br /> SUMP S . Bravo Systems 8577 Series FRP <br /> UNDER-DISPENSER S . Bravo Systems B -8000 Series FRP <br /> CONTAINMENT <br /> PENETRATIONS S . Bravo Systems F-20 F-30 FRP <br /> 8of8 <br />