Laserfiche WebLink
Probe Models <br /> Mag Plus Probes for Alternative Mag Plus Probes for Alternative <br /> Fluids with Water Detection Part No* Fluids without Water Detection Part No* <br /> Tank I. D. 0. 1 GPH Leak 0. 2 GPH Leak Inventory Oai GPH Leak 0.2 GPH Leak Inventory <br /> Detection Detection Only Detection Detection Only <br /> 4' 846391 -101 846391 -201 846391 -301 846391 -401 846391 -501 846391 -601 <br /> 5' 846391 -102 846391 -202 846391 -302 846391 -402 846391 -502 846391 -602 <br /> 5'4" 846391 -103 846391 -203 846391 -303 846391 -403 846391 -503 846391 -603 <br /> 6' 846391 -104 846391 -204 846391 -304 846391 -404 846391 -504 846391 -604 <br /> 7' 846391 -105 846391 -205 846391 -305 846391 -405 846391 -505 846391 -605 <br /> 736" 846391 -106 846391 -206 846391 -306 846391 -406 846391 -506 846391 -606 <br /> 8' 846391 -107 846391 -207 846391 -307 846391 -407 846391 -507 846391 -607 <br /> 9' 846391 A 08 846391 -208 846391 -308 846391 -408 846391 -508 846391 -608 <br /> 916" 846391 -117 846391 -217 846391 -317 846391 -417 846391 -517 846391 -617 <br /> 10' 846391 -109 846391 -209 846391 .309 846391 -409 846391 -509 846391 -609 <br /> 1016" 846391 -110 846391 -210 846391 .310 846391410 846391 -510 846391 -610 <br /> 11 ' 846391A11 846391 -211 846391 -311 846391 -411 846391 -511 846391 -611 <br /> 12' 846391Al2 846391 -212 846391 -312 846391 -412 846391 -512 846391 -612 <br /> 2.OM 846391 -113 846391 -213 846391 -313 846391 -413 846391 -513 846391 -613 <br /> 2.51VI 846391A 14 846391 -214 846391 -314 846391414 846391 -514 846391 -614 <br /> 2.67M 846391A16 846391 -216 846391 -316 846391416 846391 -516 846391 -616 <br /> 3.0M 846391 -115 846391 -215 846391 -315 846391415 846391 -515 846391 -615 <br /> Custom 846391 A 99 846391 -299 846391 -399 846391499 846391 -599 846391 -699 <br /> Length <br /> Tbat k'ts must be ordered separatey from probes. water Awls not recommended for fuel blends with >20% alcohol <br /> Floats Match Table <br /> Product Probe Functions Float Kit <br /> Inventory: Yes <br /> Mag Plus Probe for Alternative Fluids with Water Detection Leak Detection: Yes Gasoline Float Kit <br /> P/N 846391Axx or -2xx P/N 846400-xy0' <br /> Water detection: Yes ('see note for <br /> Gasoline (<=20% Alcohol) Inventory Only Mag Plus Probe for Alternative Fluids with Inventory: Yes <br /> definition of xy <br /> Water Detection Leak Detection: No below) <br /> P/N 846391 -3xx Water detection: Yes <br /> Alcohol / Ethanol (<=100% Mag Plus Probe for Alternative Fluids without Water Inventory: Yes Alternative Fluids <br /> Alcohol, including E85) Detection Leak Detection:Yes Float Kit <br /> Methanol (<=100% Alcohol) P/N 8463914xx or -5xx Water Detection: No P/N 846400-xy4' <br /> ETRE (<=100% Ether) Mag Plus Probe for Alternative Fluids without Water <br /> Detection 'Notes: <br /> MTBE (<=100% Ether) x=0 -> 4' floats <br /> Used Oil P/N 846391 -6xx Inventory: Yes x=1 -> 2' floats <br /> Fuel Oil #4 & #6 Leak Detection:No x=3 -> 3' floats <br /> Fuel Oil #4 & 46 Mag Plus Probe for Alternative Fluids without Water Detection: No <br /> Ethylene Glycol Water Detection y=0 -> 5' cable <br /> Propylene Glycol P/N 846391 -6xx y=1 ->10' cable <br /> Windshield Washer Fluid y=2 -> 20' cable <br /> Leak Test Performance (Third Party Certified for all <br /> TLS=3xx Consolesl <br /> PROBE TEST TYPE P(D) P(FA) TEST TIME <br /> 0.1 GPH Mag Probe 0.1 GPH 99% 196 3 Hours <br /> 0.1 GPH Mag Probe 0.2 GPH 99% < . 1 % 2 Hours <br /> 0.1 GPH Mag Probe w/CSLD 0.2 GPH 99% <.1 % Continuous <br /> 0.2 GPH Mag 2 0.2 GPH 99% <.1 % 2 Hours <br /> veedarRoot reserves the right to change prockxt spwAcations without advance notice. Please ensure that you are isag the <br /> latest version of product 6leratre. <br /> VEEDER- ROOT O 2007 Veeder-Root Company 125 Powder Forest Drive Simsbury, CT 06070 USA <br /> `� Telephone: 860-651 -2700 Fax : 860-651 -2719 wwGvveeder.com <br /> VR 12960 P/N 577013-054 Rev C VR 6/07 <br />