Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: FDat,-.CHARTER WAY PETRO INC. 508 W DR MARTIN LUTHER KING JR BLVD, ber 19, 2022 <br /> Single-Walled Non-Pressurized Piping <br /> 404 CCR 2643(e),2661(f) Failure to conduct 0.1 gph test on single-walled gravity piping biennially or post repair(pre-1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted General violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 102 CCR 2711 Failure to submit a complete and accurate application for a permit to operate a UST. <br /> OBSERVATION: The UST Facility Operating Permit Application is lacking a valid California Department of Tax and <br /> Fee Administration (CDTFA)Underground Storage Tank Account Number. <br /> REGULATION GUIDANCE: The application for a permit to operate an underground storage tank shall include the <br /> CDTFA registration number issued to the owner of the tank, in accordance with HSC 25286. <br /> CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS), update the <br /> required information, and submit for review by the EHD. <br /> This is a minor violation. <br /> 306 HSC 25291(e)Failure to remove, analyze, and properly dispose of water in secondary containment(pre-Jul 2003). <br /> OBSERVATION: Liquid was observed in the 91-grade submersible turbine pump(STP)sump. <br /> REGULATION GUIDANCE: If water could enter into the secondary containment by precipitation or infiltration, it <br /> must be removed and disposed of properly. <br /> CORRECTIVE ACTION: This was corrected on site. The service technician removed approximately 1/4 cup of liquid <br /> from the 91 STP sump. Ensure that all sumps and annular spaces are maintained free of liquid. <br /> This is a repeat violation, Class Il. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 11/18/2022. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br /> of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br /> ($156). To schedule an appointment, please call (209)468-3420. <br /> FA0003720 PR0231057 SCO01 10/19/2022 <br /> EHD 23-01 Rev.9/16/2020 Page 4 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />