Laserfiche WebLink
EXISTING BOHNOT PART OF THIS SCOPE70'-312" STUD TO STUD31'-10" STUD TO STUD29'-2" STUD TO STUD2 RI4 RI4 RI4 RI4 RI1 RITYP.3 RI5 RI1 AD1 RITYP.1 RITYP.6 RI6 RI1 AD6 RI1 RITYP.1 RITYP.6 RI6 RI1 CT1 CT1 CTREMODEL IMAGE (RI)ADA NOTES (AD)1 RI2 RI3 RI4 RI5 RI1 ADEXISTING BUILDING FINISH TO BE REPAIRED AND PREPAREDFOR NEW PAINT, REFER TO ELEVATIONS.ERECT PLYWOOD DUST BARRIER WITH SWING GATE TOPROTECT KITCHEN DURING CONSTRUCTION.EXISTING ELECTRICAL MAIN SWITCH BOARD. REFER TOELECT. DWGS.REPLACE SUBSTRATE BELOW WINDOWS AFTER FRAMINGINSPECTION.EXISTING FLOOR SINK UNDER SODA MACHINE.CUSTOMER TOUCH POINT (CT)NEW DOOR, FRAME AND HARDWARE, SEE SCHEDULE.1 CT6 RIMODIFY EXISTING TOWER. KEEP TOWER STRUCTURE.SEE 4.0 AND STRUCTURAL DRAWINGS.STOREFRONT DOOR AND THRESHOLD COMPLY WITH ADA REQUIREMENTS.WINDOWS / DOORS:A.SEE SCHEDULE FOR WINDOW AND DOOR TYPES.B.ALL DOOR AND WINDOW OPENINGS DIMENSIONS ARE TO ROUGH OPENING.FINISH SUBSTRATES:A.PROVIDE 1/2" THICK CEMENTITIOUS BD. FROM FLOOR SLAB TO 12" A.F.F. MIN. IN LIEUOF GYP. BD. AT ALL WALLS EXCEPT SHEAR WALL SURFACES U.O.N.B.ALL JOINTS, GAPS OR SPACES LEADING TO ALL HOLLOW OR INACCESSIBLE SPACESSHALL BE SEALED WITH "NSF INTERNATIONAL" APPROVED SEALANTS.DIMENSIONS:A.DIMENSIONS THAT ORIGINATE FROM EXISTING ELEMENTS OF THE BUILDING ARE FROMFACE OF FINISH. ALL OTHER DIMENSIONS ARE TO FACE OF STUD U.O.N. REFER TOFOUNDATION PLAN FOR FACE OF CONC. DIMENSIONS.B.DIMENSIONS NOTED AS "CLEAR" OR " HOLD" ARE MIN. REQUIRED NET CLEARANCE FROMFACE OF OUTERMOST FINISH (WALL, BASE, CHAIR RAIL).GENERAL:A.DRAWINGS ARE BASED UPON WOOD FRAMING. UTILIZATION OF METAL STUDS ONNON-BARING INTERIOR PARTITIONS, BULKHEADS AND SOFFITS IS ACCEPTABLE.B.ALL ATTACHMENTS MADE THROUGH E.I.F.S. SHALL BE BUSHED TO PREVENT DAMAGETO THE FINISH.C.ALL PENETRATIONS THROUGH E.I.F.S. SHALL BE SEALED USING MFR'S. APPROVEDMETHOD.D.VERIFY FINAL EQUIPMENT SIZES W/ VENDOR PRIOR TO INT. WALL FRAMING.DECOR:A.SEE A2.0 FOR FF&E PLANB.SEE A7.0 FOR FLOOR FINISHESC.SEE A7.1 FOR CEILING FINISHES.D.SEE A8.0-A8.1 FOR WALL FINISHESTYPICAL EXISTING WALLTYPICAL EXISTING COOLER/FREEZER WALLTYPICAL NEW WALLINTERIOR WALL :WD STUDS AT 16" O.C. AS INDICATEDEXTERIOR WALL:2X6 WD STUDS AT 16" O.C. W/ SHEATHING AS SCHEDULED(SEE STRUCT. DWGS.) AND R-19 KRAFT-FACED FIBERGLASSBATT INSULATION U.O.N.12X4 WOOD STUDS22X6 WOOD STUDS32X6 WOOD STUDSWALL SUBSTRATES:-DINING ROOM:1/2" CEMENT BOARD FROM T.O. SLAB TO 12" A.F.F. AT 12" A.F.F., USE 1/2" GYPSUM WALLBOARD TO 6" ABOVE CEILING HEIGHTU.O.N. SEE 6, 8 & 16 / A6.3.(NOTE: THE CEMENT BOARD SPECIFICATION IS DESIGNED TO ALLOW THE G.C. FLEXIBLITY. )-KITCHEN WALLS AND DINING ROOM CLOSET:1/2" CEMENT WALLBOARD FROM T.O. SLAB TO 12" A.F.F. AT 12" A.F.F., USE 1/2" CDX PLYWOOD W/FRP SURFACE FINISH TO 6"ABOVE CEILING HEIGHT U.O.N. IF DOUBLE SIDED SHEAR WALL PLYWD IS SPECIFIED THE PLYWOOD SHALL SHALL BE CONTINUOUSFROM SILL PLATE TO TOP PLATE. SEE 4, 11 & 20 / A6.3.-RESTROOM WALLS:5/8" CEMENT WALLBOARD FROM T.O. SLAB OR T.O. CONCRETE CURB TO 6" ABOVE CEILING HEIGHT U.O.N.. NO SUBSTITUTIONSALLOWED. FINISH AS SCHEDULED. SEE 11 (SIM), 12 /A6.3.-ALL OTHER FRAME WALL CONDITIONS:1/2" CEMENT WALLBOARD FROM T.O. SLAB OR T.O. CONCRETE CURB TO 12" A.F.F., WITH 1/2" GYPSUM WALLBOARD FROM T.O.CEMENT BOARD TO 6" ABOVE CEILING HEIGHT U.O.N. FINISH AS SCHEDULED.A1.0FLOOR PLANAFLOOR PLANBKEY NOTESCONTRACT DATE:BUILDING GROUP:FLOOR PLAN:SITE NUMBER:STORE NUMBER:REVISION DATE:PLOT DATE:ArchitecturalSolutions GroupPACIFIC BELLS, INC.111 W. 39TH STREETVANCOUVER, WA 98660360.694.7855TACO BELL1100 Yosemite AveEscalon, CA 95320K SUCCESSORREMODELME - K50MAY 2019-3418906.15.20NTP SUBMITTAL06.05.20CLIENT REVIEW07.09.201ST SUBMITTALSTATE OF CALIFORN IA LICENSED ARCHITECTRenewal: 6/30/21KENNETHMCCRACKENC-32095CITY USE ONLY:KJM/2620DWALL LEGENDCFLOOR PLAN NOTES