REFER TO ME1.0 SHEET FOR SCHEDULE.REMODEL IMAGE (RI)1 RIREMOVE EXISTING PENDANTS & DOWN LIGHTS . REMOVE WIRING BACK TO SOURCE OR NEAREST JBOX TOREMAIN IF NOT BEING USED FOR NEW FIXTURE. REPAIR DRYWALL.REPLACE EXISTING DIFFUSERS WITH NEW IN SAME LOCATION.REMOVE EXISTING EMERGENCY EGRESS/EXIT LIGHTING.REMOVE EXISTING REVOLUTION MENU BOARD. PREP FOR INSTALLATION OF NEW DIGITAL MENU BOARDS.REMOVE EXISTING FLUORESCENT LIGHT FIXTURES WITHIN THE DINING ROOM, RESTROOMS AND ALCOVE.REMOVE EXISTING CEILING TILES AND T-BAR CEILING GRID, PREP FOR REPLACEMENT. REFER TO A7.2FOR FINISH.EXISTING SPEAKERS TO REMAIN. TEMPORARILY SUPPORT SPEAKER AND PREP GRILLE FOR NEW PAINT.EXISTING SOFFIT AND BULKHEAD TO REMAIN. PATCH AND REPAIR AS NEEDED.REMOVE EXISTING SMOKE DETECTOR IN RESTROOM. SAVE FOR REINSTALLATION.REPLACE EXISTING DIFFUSERS IN RESTROOMS WITH NEW IN SAME LOCATION. REFER TO ME1.0 SHEET FOR SCHEDULE.EXISTING GYP. BD. CEILING TO REMAIN. PATCH AND REPAIR. PAINT PER FINISH SCHEDULE.REMOVE EXISTING AWNING. PATCH AND REPAIR AS NEEDED. SEE EXTERIOR ELEVATIONS.EXISTING EXTERIOR LIGHT FIXTURES TO REMAIN, PROTECT DURING CONSTRUCTION.NOT USED2 RI3 RI4 RI5 RI6 RI7 RI8 RI10 RI9 RI11 RI12 RI13 RI14 RIEXISTING BOHNOT PART OF THIS SCOPE1 RI5 RI6 RI5 RI9 RI10 RI11 RI5 RI9 RI10 RI11 RI2 RI7 RI12 RI11 RI8 RI12 RI12 RI12 RI12 RI3 RI3 RI13 RI13 RI13 RI13 RI13 RI13 RI13 RI13 RI13 RI4 RID2.0DEMOLITIONREFLECTEDCEILING PLANCONTRACT DATE:BUILDING GROUP:FLOOR PLAN:SITE NUMBER:STORE NUMBER:REVISION DATE:PLOT DATE:ArchitecturalSolutions GroupPACIFIC BELLS, INC.111 W. 39TH STREETVANCOUVER, WA 98660360.694.7855TACO BELL1100 Yosemite AveEscalon, CA 95320K SUCCESSORREMODELME - K50MAY 2019-3418906.15.20NTP SUBMITTAL06.05.20CLIENT REVIEW07.09.201ST SUBMITTALSTATE OF CALIFORN IA LICENSED ARCHITECTRenewal: 6/30/21KENNETHMCCRACKENC-32095CITY USE ONLY:KJM/2620BDEMOLITION KEY NOTESADEMOLITION REFLECTIVE CEILING PLANDEMO ITEMS AS INDICATED (SEE KEY NOTES)CDEMOLITION LEGEND1.GENERAL CONTRACTOR SHALL VISIT THE PROJECT SITE TO VERIFY ALL FIELDCONDITIONS AS THEY RELATE TO DEMOLITION INDICATED ON THIS PLAN. NOTIFY THEARCHITECT IMMEDIATELY IF ANY DISCREPANCY IS FOUND.2.GENERAL CONTRACTOR SHALL EXECUTE ALL DEMOLITION AND REMOVAL CAREFULLY,SO AS TO MINIMIZE INTERFERENCE WITH EXISTING CONDITIONS, NEW CONDITIONS, ORSITE CONDITIONS. IF ANY STRUCTURAL COMPONENTS ARE UNCOVEREDUNEXPECTEDLY DURING DEMOLITION, THE GENERAL CONTRACTOR SHALL STOPWORK IMMEDIATELY AND NOTIFY THE ARCHITECT AT ONCE.3.WHERE PLUMBING, MECHANICAL OR ELECTRICAL SYSTEMS/ITEMS ARE SPECIFIED TOBE REMOVED, THE GC SHALL ENSURE THAT THE SYSTEMS AREABANDONED/SEALED/CAPPED TO THE EXTENT THAT THEY IN NO WAY INTERFERE WITHFINAL FINISH CONDITIONS. THERE SHALL BE NO INDICATION OF PREVIOUSINSTALLATION WHATSOEVER. ANY DISCREPANCIES SHALL BE BROUGHT TO THEATTENTION OF THE ARCHITECT AT ONCE.4.WHERE EXISTING WALLS, CASEWORK, FIXTURES, EQUIPMENT, ETC. ARE TO BEREMOVED, NEWLY REVEALED SURFACES SHALL BE CLEANED SO AS TO ACCEPT NEWFINISH MATERIALS AS IDENTIFIED IN ROOM FINISH SCHEDULE. ALL UNNECESSARYBRACKETS, CLIPS, HANGERS, NAILS, LEDGER BOARDS, ETC. THROUGHOUT THE SPACESHALL BE REMOVED. WORK SHALL BE PERFORMED SO AS TO LEAVE NO INDICATIONOF PREVIOUS DEMOLITION.DGENERAL NOTESBUILDING RESPONSES02.18.21