Laserfiche WebLink
COEWFGCOCDAFFVTRSANCLEAN OUTPRESSURE REGULATING VALVE (PRV) (50 PSI)GRADE CLEAN OUTELECTRIC WATER FOUNTAINBALL VALVECONDENSATE DRAIN PIPINGABOVE FINISHED FLOORUNIONPIPE TURNING UPPIPE TURNING DOWNVENT THROUGH ROOF140° WATER PIPINGPLUMBING TRAPSANITARY WASTE PIPINGCOLD WATER PIPINGHOT WATER PIPING (140°)POINT OF CONNECTI0NPLUMBING SYMBOLS LEGENDCIRCUIT SETTER BALANCE VALVEFWFILTERED WATER PIPINGGGAS PIPINGCHECK VALVEGREASE WASTE PIPINGSANITARY VENT PIPING140°GWBALANCE VALVEHOT WATER RECIRCULATING PIPINGBELOW FLOORABOVE CEILINGFCPDPUMP DISCHARGEPLUMBING FIXTURE SCHEDULEDESIGNATIONMODEL NUMBERMFR.COLDWATERHOTWATERWASTEVENTSIZEREMARKSP-1WATER CLOSETK-3619ADA COMPLIANT ELONGATEDBOWLKOHLER12"-4"2"18" HIGH BOWL CSEAT AND CAP BOLTS. 1.28 GAL PERFLUSH INSTALL WITH ANGLE STOP. PROVIDE "WHITE"COLOR SELECTION FOR CHINA.P-2LAVATORY SINKK-2032ADA COMPLIANTKOHLER12"12"2"2"DELTA FAUCET 501LF-HGMHDF SINGLE LEVER WITH 0.5GPM VANDAL RESISTANT AERATOR, GRID STRAINERTAILPIECE, OFFSET WHEELCHAIR TRAP LOOSE KEY STOP.INSTALL HANDLE LIMIT STOP KIT WITHIN SINGLE LEVELMIXING FAUCET TO LIMIT OUTLET HOT WATER SUPPLY TO110°F.P-3MOP SINKZ1996-24ZURN34"34"3"2"MOP SERVICE BASIN WITH 10" HIGH WALLS 3" DRAIN830-AA SERVICE FAUCETS WITH VACUUM BREAKER,INTEGRAL STOPS AND HOSE WITH HOSE BRACKET.P-4FLOOR SINKZ1900ZURN--4"2"12" X 12" X 6" DEEP CAST IRON BODY WITH WHITEPORCELAIN ENAMELP-7FLOOR DRAINFD2201ZURN--2"2"POLISHED BRASS STRAINER, AND TRAP PRIMER. LOCATEPRIMER WITH SHUT-OFF VALVE AND ACCESS PANEL INWALL. COORDINATE WITH GENERAL CONTRACTOR.P-9GREASE INTERCEPTORGB-50SCHIER--4"2"SCHIER GB-50 50GPM BELOW-GRADE GREASEINTERCEPTORP-10WATER HEATERRUR199INRINNAI1"1"-3"199,000 BTU TANKLESS WATER HEATER. PROVIDE T&PRELIEF VALVE, BRASS DRAIN VALVE FOAM INSULATIONPER ASHRAE STANDARD, GAS PRESSURE REGULATORAND ANODE ROD. PROVIDE AND INSTALL INTAKE ANDEXHAUST AIR FLUES IN ACCORDANCE WITHMANUFACTURE'S INSTALLATION INSTRUCTIONS.P-11WALL HYDRANTHY-420-8WATTS1/2"---NON-FREEZE WALL HYDRANT, MOUNT AT 24"A.F.F. ATREAR ELEVATION.P-12YARD HYDRANTEVERBILTWATTS1/2"---FROST PROOF 2FT. BURY DEPTHP-13HAND SINK7-PS-56ADVANCETABCO12"12"2"2"PROVIDED BY DBC, INSTALLED BY GC.P-143 COMPARTMENT SINKBY OWNER-12"12"(3)2"-PLUMBING CONTRACTOR TO PROVIDE 12" CW AND 12" HWSUPPLY LINES WITH ANGLE VALVE SHUOFF AND SUPPLYSTOPS TO SINK FAUCET. PLUMBING CONTRACTOR TOPROVIDE (3) 2" WASTE LINES FROM EACH BAY ANDINDIRECT WASTE TO FLOOR SINK BELOW.P-15PULL-OUT SPRAYER HANDLET&S(T&SBRASS.COM)----TO BE INSTALLED IN DB PROVIDED STAINLESS STEELTABLEP-16WATER FILTERBY OWNEREVERPURE114"---PLUMBING CONTRACTOR SHALL INSTALL WATER FILTERSUPPLIED BY OWNER. PROVIDE WITH BALL ISOLATIONVALVE AND UNION ON BOTH ENDS OF ALL CONNECTIONS.PROVIDE RPZ WITH DRAIN CUP IF REQUIRED BY CODE.CP-1CIRCULATING PUMP0010TACO----115V, 3250 RPM, PROVIDE WITH AQUASTAT AND/OR TIMERAS REQUIRED.BP-1BOOSTER PUMPAQUAVAR BAQUABII1151AB25HM03AQUAVAR1-1/4"---1 HP VARIABLE SPEED CONTROLLER, 115V INPUT, 30 GPM@ 35 PSI BOOST. PROVIDE ALL NECESSARY VALVES ANDACCESSORIES RECOMMENDED BY MANUFACTURER FORA COMPLETE SYSTEM.KITCHEN FIXTURE SCHEDULEDESIGNATIONMFR. AND MODEL NUMBERCOLDWATERFILTEREDCOLDWATERHOTWATERWASTEVENTSIZEREMARKSEQ-1ESPRESSO MACHINE(3 MACHINE GROUP)BY OWNER-(4)12"-(3)34"-CONTRACTOR TO PROVIDE 12" FW LINE WITH BRAIDED FLEX HOSE AND BALLVALVE SHUT-OFF. PROVIDE 34" INDIRECT WASTE LINE TO FLOOR SINK BELOW.TYPICAL OF 3 MACHINES IN GROUP.EQ-4DIPPERWELL FAUCET &SINK ASSEMBLY12"--12"-EQ-9ICE MACHINEBY OWNER-(2)12"-34"-CONTRACTOR TO PROVIDE 12" FW LINE WITH BALL VALVE SHUT-OFF AND PROVIDEFINAL COLD WATER CONNECTION TO ICE MACHINE. PROVIDE 34" INDIRECT WASTELINE TO FLOOR SINK BELOW. BACKFLOW ON FILTER ASSEMBLY IF REQUIRED.NOTE: PC AND EC TO PROVIDE ADDITIONAL OUTLET AND WATERLINE STOP FORFUTURE 2ND ICE MACHINE.EQ-10ICE STORAGE BINBY OWNER---34"-PROVIDE 34" INDIRECT WASTE LINE TO FLOOR SINK BELOW.EQ-11BUNN WATER DISPENSERBY OWNER-(4)12"---CONTRACTOR TO PROVIDE 12" FW WITH BALL VALVE SHUT-OFF. SUPPLIED WITHASSE 1022 INLINE CARTRIDGE BACKFLOW.EQ-12RAPID RINSE STATIONBY OWNER---34"-PLUMBING CONTRACTOR TO PROVIDE 12" HW LINE WITH BALL VALVE SHUT-OFF.PROVIDE FINAL COLD WATER CONNECTION TO RAPID RINSE STATION. PROVIDE 34"INDIRECT WASTE LINE TO FLOOR SINK BELOW. (PROVIDE RPZ IF REQUIRED BYLOCAL CODE)EQ-19GLASS FILLERBY OWNER-(4)12"---12 " FILTER WATER SUPPLY - NO DRAIN REQUIREDGENERAL NOTES:1.PLUMBING CONTRACTOR SHALL STRAP UP ALL SUPPLY LINES TIGHT TO STAINLESS TABLES WITH ZIPTIES SO THAT UNDER COUNTER EQUIPMENT CAN BE REMOVEDWITHOUT GETTING CAUGHT IN THE BRAIDED STAINLESS SUPPLY LINES.2.PLUMBING CONTRACTOR SHALL RUN DRAINS OFF OF STAINLESS TABLES AND DRINK EQUIPMENT IN RIGID ABS OR PVC PIPE. DRAINS ARE TO BE RUN TOWARD THECENTER OF THE FLOOR SINK BENEATH EACH TABLE. DRAINS WILL FIT BETWEEN THE WHEELS OF THE ROLLING ICE BINS. PC TO STRAP DRAINS TO FLOOR WITHUNISTRUT OR SIMILAR.NATURAL GASCALCULATIONAPPLIANCESDEMAND(MBH)RTU-1115.0RTU-2115.0WATER HEATER398.0TOTAL BTU LOAD628SYSTEM LENGTH48DEVELOPED PIPE LENGTH60SANITARY SIZING CALCULATIONFIXTUREDESIGNATIONDFUWASTEQUANTITYTOTALWATER CLOSETP-1414LAVATORYP-2111FLOOR DRAINP-752103 COMP SINKP-14616FLOOR SINKP-4666HAND SINKP-13224MOP SINKP-3313PER 2016 CALIFORNIA PLUMBING CODETOTAL (DFU)64STATIC PRESSURE60.0PRESSURE DROP THRU FRICTION LOSS FROM MAINTO METER (12" WATER LINE)0.0PRESSURE DROP THRU METER5.0PRESSURE DROP THRU FRICTION LOSS FROMMETER TO BACKFLOW5.2PRESSURE DROP THRU BACKFLOW AND STRAINER15.0PRESSURE DROP DUE TO ELEVATION TO PUMP4.3PRESSURE AVAILABLE @ PUMP22.5PRESSURE AVAILABLE AFTER PUMP57.5PRESSURE NEEDED AT FIXTURES35.0PRESSURE DROP DUE TO ELEVATION4.0REMAINING PRESSURE26.5SYSTEM LENGTH150EQUIVALENT PIPE LENGTH187.50FTALLOWABLE LOSS PER 100FT OF PIPE:26.5PSI X 100FT187.50 FT14.1FIXTURE UNITS DOMESTIC WATERFIXTURESQUANTITYCOLD WATERHOTWATERHAND SINK111LAVATORIES111WATER CLOSETS12.50.0KITCHEN SINK266MOP SINK122WATER DISPENSER440ESPRESSO MACHINE (3MACHINE GROUP)4120.0ICE MAKER11.00.0RAPID RINSE55.00.0TOTAL34.500010.0000GPM208FORMULA FOR SIZING GREASE INTERCEPTORSLength X Width X Depth/231= Gallons X .75 Fill Factor X Number of Compartments= Size of Grease Interceptor (GPM)16"14"14"20231/XX=X.75 Fill FactorDischarge from 3-Compartment Sink Compartment Deminsions:X3 Compartments=31 GalINTERIOR/EXTERIOR IN-FLOOR GREASE INTERCEPTORSFIXTURENUMBER OFFIXTURESFIXTUREVALUE UNITTOTAL FIXTURESUNITS2 DFUPER GPMxx=FLOOR FIXTURES73242xx=/=FLOW RATING GPM12/=46.5=TOTAL REQUIRED FLOW RATING GPMHAND SINKS2242xx=2.0/=SERVICE BASIN132xx=/=31.5**Total GPMRetention Time/31 Gal/1 Min=31 GPMGREASE WASTE SIZE:4" FLOOR SINKS RECEIVING DISCHARGE FROM COMPARTMENT SINK(S), NOT COUNTED. REFER TO VOLUME CALCULATION FOR SINKS INTHIS TABLE.GENERAL NOTES:1.EXACT LOCATION OF PLUMBING FIXTURES SHALL BEDETERMINED FROM ARCHITECTURAL DRAWINGS.2.BEFORE SUBMITTING BID, THE PLUMBING CONTRACTORSHALL REVIEW THE ARCHITECTURAL DRAWINGS ANDINCLUDE IN HIS BID AN AMOUNT TO FURNISH AND INSTALLANY FIXTURES WHICH ARE SHOWN IN ADDITION TOFIXTURES SHOWN ON THE PLUMBING DRAWINGS.3.CONTRACTOR SHALL VERIFY INVERT ELEVATION OFSEWERS TO WHICH NEW WASTE LINES ARE TO BECONNECTED BEFORE MAKING UP OR INSTALLATION OF NEWWASTE SYSTEM.4.CONTRACTOR SHALL VERIFY AND COORDINATE LOCATIONOF ALL PLUMBING LINES WITH DUCTWORK AND ELECTRICALSERVICES.5.THE INSTALLATION OF ALL VALVES, UNIONS,THERMOMETERS, GAUGES, OR OTHER INDICATING ORRECORDING EQUIPMENT, OR SPECIALTIES REQUIRINGFREQUENT READING, REPAIRS, ADJUSTMENT, INSPECTION,REMOVAL OR REPLACEMENT SHALL BE CONVENIENTLY ANDACCESSIBLY LOCATED WITH REFERENCE TO THE FINISHEDBUILDING.6.WHERE POSSIBLE, THE VENTS TOGETHER SO THAT AMINIMUM NUMBER TERMINATE THROUGH THE ROOF.7.WATER CLOSETS IN PUBLIC TOILET ROOMS SHALL CENTERON THE FINAL LAYOUT OF TOILET PARTITIONS.8.ALL VENTS THROUGH ROOF SHALL BE AT LEAST 10'REMOVED FROM ALL AIR INTAKES, EVAP. COOLERS.9.CONTRACTOR SHALL NOT CUT HOLES IN STRUCTURALMEMBERS WITHOUT FIRST SECURING WRITTEN APPROVALFROM ARCHITECT.10.CONTRACTOR SHALL INSTALL DIELECTRIC UNIONS ATCONNECTION OF DISSIMILAR METALS.11.CONTRACTOR SHALL ROUGH-IN ALL WASTE AND SUPPLIESTO SPECIAL EQUIP. ACCORDING TO MANUFACTURERS SHOPDRAWINGS AND MAKE FINAL CONNECTIONS ALL SUPPLIESSHALL BE VALVED.12.ASSUMED WATER PRESSURE-CONTRACTOR SHALL VERIFYACTUAL WATER PRESSURES PRIOR TO CONSTRUCTION. IFPRESSURE IS LESS THAN 60 PSI, CONTRACTOR SHALLCONTACT THE ENGINEER FOR PIPE SIZING EVALUATION. IFPRESSURE EXCEEDS 80 PSI, A PRESSURE REDUCING VALVESHALL BE PROVIDED. PIPING VELOCITY SHALL NOT EXCEED8 FPS AND HOT WATER VELOCITY SHALL NOT EXCEED 5FPS.FIELD VERIFICATION NOTES:1.THE PLUMBING CONTRACTOR SHALL VISIT THE SITE PRIOR TOBID TO FIELD VERIFY ALL EXISTING CONDITIONS WHICH MAYAFFECT HIS BID. THE FOLLOWING ITEMS SHALL BE VERIFIED.1.A.EXACT PLACEMENT SIZE CAPACITY MANUFACTURER ANDCONDITION OF ALL EXISTING PLUMBING EQUIPMENT WITHINSCOPE OF WORK, WHETHER SPECIFICALLY SHOWN OR NOT.1.B.SIZE AND LOCATION OF ALL EXISTING WASTE, GREASEWASTE, VENT AND WATER PIPING.2.ALL REFERENCES ON THESE DRAWINGS TO EXISTINGEQUIPMENT, WATER IS THE RESPONSIBILITY OF THECONTRACTOR TO VERIFY ALL THESE ITEMS PRIOR TO BID ANDINCLUDE IN HIS BID ANY AND ALL AMOUNTS REQUIRED TOACCOMMODATE EXISTING CONDITIONS.3.NO ALLOWANCES WILL BE MADE AFTER THE PROJECT HASBEEN AWARDED FOR FAILURE TO VERIFY EXISTINGCONDITIONS.4.ANY DISCREPANCIES WHICH MAY AFFECT THE CONTRACTORBID SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEERAND ARCHITECT FOR DIRECTION.5.PLUMBING ROUTINGS BASED ON OWNER'S SCHEMATICS OFLOCATION OF EXISTING FIXTURES AND SHELL DRAWINGS.CONTRACTOR RESPONSIBLE FOR VERIFICATION OF ACTUALLOCATION OF SUPPLY LINES AND MAKING APPROPRIATEADJUSTMENTS TO ACTUAL CONDITIONS IN THE FIELD.6.PRIOR TO CONSTRUCTION, VERIFY THE LOCATION OF THEHVAC/WALK-IN CONDENSATE FLOOR SINK. IF SLOPE ANDDISTANCE OR IF IT IS INFEASIBLE TO DISPOSE OF WALK-INCOOLER CONDENSATE. USE A CONDENSATE PUMP.D:\my Documents\DJC-CA.jpgSHEET NAME:SHEET NUMBER:DESCRIPTION:DATE:REV:ISSUED FOR PERMIT:03.20.20““”“””c1001 SE SANDY BLVD, SUITE 100PORTLAND, OR 97214V. 503.552.9079F. 503.241.7055WWW.GNICHARCH.COM03.20.20796 Merus CourtSt. Louis, MO 63026T 636.349.1600F 636.349.1730Project No: CA-0805 <br />Dutch Bros Coffee - New Freestanding Store <br />15135 Old Harlan Road <br />Lathrop, CA 95330 <br />for: Cherng Family Trust <br />1120 N. Town Center Drive, Suite 150 <br />Las Vegas, Nevada 89144 DB2040 - A1P1.0PLUMBINGSPECIFICATIONS &SCHEDULES