Laserfiche WebLink
<br />Monthly Checklist Page 2 of 3 <br /> <br />4 <br />Is the primary tank free of water or has another preventative measure been taken? <br />NOTE: Refer to paragraphs 6.10 and 6.11 of the standard for alternatives for Category 1 <br />tanks. N/A is only appropriate for these alternatives. <br />□ Yes □ No □ N/A <br /> <br />5 For double-wall or double bottom tanks or CE-ASTs, is interstitial monitoring equipment <br />(where applicable) in good working condition? □ Yes □ No □ N/A <br />6 For double-wall tanks or double bottom tanks or CE-ASTs, is interstice free of liquid? <br />Remove the liquid if it is found. If tank product is found, investigate possible leak. □ Yes □ No □ N/A <br />Equipment on tank <br />7 If overfill equipment has a “test” button, does it activate the audible horn or light <br />to confirm operation? If battery operated, replace battery if needed. □ Yes □ No □ N/A <br />8 Is overfill prevention equipment in good working condition? If it is equipped with a <br />mechanical test mechanism, actuate the mechanism to confirm operation. □ Yes □ No □ N/A <br />9 Is the spill container (spill bucket) empty, free of visible leaks and in good working <br />condition? □ Yes □ No □ N/A <br />10 Are piping connections to the tank (valves, fittings, pumps, etc.) free of visible leaks? <br />Note: If "No", identify location and describe leak. □ Yes □ No <br />11 Do the ladders/platforms/walkways appear to be secure with no sign of severe corrosion <br />or damage? □ Yes □ No □ N/A <br />Containment (Diking/Impounding) <br />12 Is the containment free of excess liquid, debris, cracks, corrosion, erosion, fire hazards and <br />other integrity issues? □ Yes □ No □ N/A <br />13 Are dike drain valves closed and in good working condition? □ Yes □ No □ N/A <br />14 Are containment egress pathways clear and any gates/doors operable? □ Yes □ No □ N/A <br />Concrete Exterior AST (CE-AST) <br />15 Inspect all sides for cracks in concrete. Are there any cracks in the concrete exterior larger <br />than 1/16”? □ Yes □ No □ N/A <br />16 Inspect concrete exterior body of the tank for cleanliness, need of coating, or rusting where <br />applicable. Tank exterior in acceptable condition? □ Yes □ No □ N/A <br />17 <br />Visual inspect all tank top openings including nipples, manways, tank top overfill containers, <br />and leak detection tubes. Is the sealant between all tank top openings and concrete intact <br />and in good condition? <br />□ Yes □ No □ N/A <br /> <br />Other Conditions <br />18 Is the system free of any other conditions that need to be addressed for <br />continued safe operation? □ Yes □ No