V
>
VICTOR
>
1400
>
2800 - Aboveground Petroleum Storage Program
>
PR0529108
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/11/2022 8:32:52 AM
Creation date
3/7/2022 10:41:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0529108
PE
2832
FACILITY_ID
FA0003704
FACILITY_NAME
DART CONTAINER CORP
STREET_NUMBER
1400
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04932015
CURRENT_STATUS
01
SITE_LOCATION
1400 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Annual Checklist Page 3 of 4 <br /> <br />16 <br />Are all valves free of leaks, corrosion and other <br />damage? Follow manufacturers’ instructions for <br />regular maintenance of these items. Check the <br />following and verify (as applicable): <br /> <br />□ Anti-siphon valve <br />□ Check valve <br />□ Gate valve <br />□ Pressure regulator valve <br />□ Expansion relief valve <br />□ Solenoid valve <br />□ Fire valve <br />□ Shear valve <br /> <br /> <br /> <br /> <br /> <br />□Yes □No □N/A <br />□Yes □No □N/A <br />□Yes □No □N/A <br />□Yes □No □N/A <br />□Yes □No □N/A <br />□Yes □No □N/A <br />□Yes □No □N/A <br /> <br /> <br />17 Are strainers and filters clean and in good condition? □Yes □No □N/A <br />Insulated Tanks <br />18 <br />Free of missing insulation? <br />Insulation free of visible signs of damage? <br />Insulation adequately protected from water intrusion? <br />□Yes □No □N/A <br />19 Insulation free of noticeable areas of moisture? □Yes □No □N/A <br />20 Insulation free of mold? □Yes □No □N/A <br />21 Free of visible signs of coating failure? □Yes □No □N/A <br />Tank / Piping Release Detection <br />22 Is inventory control being performed and documented <br />if required? □Yes □No □N/A <br />23 Is release detection being performed and documented <br />if required? □Yes □No □N/A <br />Other Equipment <br />24 Are electrical wiring and boxes in good condition? □Yes □No □N/A <br />25 <br />Has the cathodic protection system on <br />the tank been tested as required by <br />the designing engineer? <br />□Yes □No □N/A