My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2115
>
2300 - Underground Storage Tank Program
>
PR0526335
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/19/2023 4:22:06 PM
Creation date
3/9/2022 3:42:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0526335
PE
2351
FACILITY_ID
FA0017819
FACILITY_NAME
CAGASOLINE INC
STREET_NUMBER
2115
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
2115 W YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br />__COU N rY <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />CAGASOLINE INC <br />2115 W YOSEMITE AVE, MANTECA <br />March 21, 2022 <br />Other Violations <br />2010 <br />See below <br />Unlisted General violation <br />-I V -. R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS 1, CLASS II, or MINOR - Notice to Comply) <br />IteTZRemarks <br />122 <br />CCR 2712(f) Failure to implement corrections and submit written response within 30 days of receiving the report. <br />OBSERVATION: An inspection was last done on 03/09/2021 and an inspection report was issued identifying <br />nformation to be submitted to bring this site into compliance. This information was required to be submitted by <br />04/08/2021 . This information was received and incomplete on 05/20/2021 one month late resulting in a <br />non-compliant status for this facility. <br />REGULATION GUIDANCE: An operator that receives an inspection report shall have 30 days to implement the <br />corrections specified in the inspection report and comply with permit conditions. The corrective action shall include <br />all of the recommendations made in the report The operator shall submit a written response that includes a <br />statement documenting corrective actions taken or proposing corrective actions which will be taken. <br />CORRECTIVE ACTION: Ensure that a written response documenting corrective actions taken or proposed is <br />submitted and all corrections implemented within 30 days of receiving an inspection report. <br />This is a repeat violation, Class II. <br />307 <br />HSC 25290.1(c3), 25290.2(c3) Failure to keep water out of the secondary containment system (post -Jul 2003). <br />OBSERVATION: little amount of water was found in the Diesel STP and 91 fill sumps. <br />RE=GULATION GUIDANCE: Secondary containment shall be constructed to prevent any water intrusion into the <br />es <br />m by precipitation, infiltration, or surface runoff. <br />CORRECTIVE ACTION: The service technician removed approximately two cups of liquid from the diesel and 91 <br />fill sumps and returned the sensor to its proper location. Immediately contact a properly licensed, trained, and <br />certified contractor to address the water intrusion into the diesel and 91 fill sumps under permit and inspection of the <br />EHD. <br />This was corrected on site. <br />This is a repeat violation, Class II, <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 0412012022. <br />To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br />of having them sign. Starting September 1, 2018, all in -office CERS help will be provided at EHD hourly rate <br />($152). To schedule an appointment, please call (209) 468-3420. <br />Documents provided during inspection: Inspection report, return to compliance certification form, corrective <br />action statement form and a schedule of free CUPA training classes. <br />FA0017819 PRO526335 SC001 03/21/2022 <br />EHD 23-01 Rev. 12106/2021 Page 4 of 5 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov,org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.