Laserfiche WebLink
Environmental Health Department <br />Aboveground Petroleum Storage Act Inspection Report <br />Date: <br />February 17, 2022 <br /> Facility Address: <br /> 2323 LOVELACE RD, MANTECA <br /> Facility Name: <br /> LOVELACE TRANSFER STATION <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 718 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas. <br />OBSERVATION: The facility failed to promptly correct visible discharges of oil from the 500 gallon diesel generator. <br />Diesel was observed running from the top of the tank to the concrete. <br />REGULATION GUIDANCE: (c)(10) Promptly correct visible discharges which result in a loss of oil from the <br />container, including but not limited to seams, gaskets, piping, pumps, valves, rivets, and bolts. You must promptly <br />remove any accumulations of oil in diked areas. <br />CORRECTIVE ACTION: Immediately fix any leaks and clean spills, and manage all wastes according to the <br />California Code of Regulations Title 22 hazardous waste regulations, submit proof of correction to the EHD. <br />This is a Class II violation. <br /> 719 CFR 112.8(c)(11) Failed to locate properly or provide sufficient secondary containment for mobile/portable <br />containers. <br />OBSERVATION: One 55 gallon drum of hydraulic oil was observed in the shop cage without secondary <br />containment. <br />REGULATION GUIDANCE: (c)(11) Position or locate mobile or portable oil storage containers to prevent a <br />discharge as described in § 112.1(b). Except for mobile refuelers and other non-transportation-related tank trucks, <br />you must furnish a secondary means of containment, such as a dike or catchment basin, sufficient to contain the <br />capacity of the largest single compartment or container with sufficient freeboard to contain precipitation. <br />CORRECTIVE ACTION: Provide adequate secondary containment for mobile or portable oil storage tanks. Provide <br />proof or correction to the EHD. <br />This is a Class II violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 03/19/2022. <br />To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br />of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br />($152). To schedule an appointment, please call (209) 468-3420. <br />The following was observed: <br />- 10.000 gallon diesel tank., <br />- 1280 gallon used oil <br />- 500 gallon diesel <br />- 280 gallon hydraulic oil <br />- 280 gallon motor oil <br />- 280 gallon used oil <br />FA0001434 PR0523546 SC001 02/17/2022 <br />EHD 28-01 Rev. 12/06/2021 Aboveground Petroleum Storage Act OIRPage 9 of 10 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD