Laserfiche WebLink
° ur I Environmental Health Department <br /> SAN-6-JOAQU <br /> CaLJT <br /> Greotness grows here. <br /> Food Program Service Request Inspection Report <br /> Facility Name and Address: GEMCO TRUCK PLAZA, 1022 FRONTAGE RD , RIPON <br /> #47 Signs Posted; Last Inspection Report Available <br /> OBSERVATIONS:Women rest room hand sink is lacking hand wash sign. Provide sign in 1 week. <br /> CALCODE DESCRIPTION:Handwashing signs shall be posted in each toilet room, directing attention to the need to thoroughly wash <br /> hands after using the restroom(113953.5)(b)No smoking signs shall be posted in food preparation, food storage, warewashing, and <br /> utensil storage areas(113978). (c)Consumers shall be notified that clean tableware is to be used when they return to self-service areas <br /> such as salad bars and buffets. (d)Any food facility constructed before January 1, 2004, without public toilet facilities,shall prominently <br /> post a sign within the food facility in a public area stating that toilet facilities are not provided(113725.1, 114381 (e)). Proper posting of <br /> nutritional information at facilities with 20 or more chains in California(114094). <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Name on Food Safety Certificate: Required Expiration Date: <br /> Warewash Chlorine(Cl): ppm Heat: °F Water/Hot Water Ware Sink Temp: 122°F <br /> Quaternary Ammonia(QA): ppm Hand Sink Temp: 120°F <br /> FOOD ITEM--LOCATION--TEMP°F--COMMENTS <br /> Prep sink--122.00°F Hand sinks--Men rest room--100.00°F <br /> Hand sink--By soda machine--104.00°F Mop sink--122.00°F <br /> Hand sink--Women rest room--100.00°F <br /> NOTES <br /> Pre final inspection. <br /> Grease trap will be installed next week and will be inspected by city of Ripon. <br /> Hood has been inspected by Fire Department on 01-26-2022 <br /> Air curtain is installed at the drive thru station and it is working properly with the window. <br /> Two gas tankless water heater(4.5 GPM at 60 degree rise each)are installed to supply the food prep area. <br /> Electric heater of 4.5 KW is installed to supply the men and women rest rooms and hand sink at the soda machine.As per <br /> owner they will not allow customers to use showers permanently. <br /> Final inspection is required. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: <br /> EH Specialist: GEHANE FAHMY Phone: (209)616-3052 <br /> SR0082304 SC523 02/17/2022 <br /> EHD 16-23 Rev.09/16/2020 Page 3 of 3 Food Program Service Request Inspection Report <br />