Laserfiche WebLink
pR 1FFlg'to <br />SYSTEM INSTALLATION <br />I. INSTALLATION GUIDELINES <br />All Geoflow drip systems require: <br />100 micron / 150 mesh filter <br />Filter flush valve <br />Field flush valve and <br />Air vent in each zone <br />All Wasteflow Classic drip systems require pressure regulation <br />Handle your dripline and components with care. ROOTGUARD 0 is temperature sensitive. To assure <br />a long life store the drip line out of direct sunlight in a cool place. This should be a consideration <br />when installing the system in very hot and sunny areas. Your system life span will be increased <br />extremes. if it <br />is buried an extra two or three inches below the soil surface, to avoid the warm temperature <br />a) All dripfield construction shall be done in accordance with Local rules and regulations. <br />b) No utilities, cable wire, drain tile, etc shall be located in dripfield. <br />c) Fence off entire dripfield prior to any construction. <br />d) System is not to be installed when ground is wet or frozen. <br />C) Divert all downspouts and surface waters away from dripficid or into curtain drains. <br />f) Excavation, filling and grading should have been finished before installation of the subsurface <br />drip system. <br />g) Be sure you have everything required for the installation before opening trenches. Pre -assemble <br />as many sets of components as practical above ground and in a comfortable place. Compression <br />or Lockslip adapters should be glued to PVC tees, riser units should be pre -assembled, the sub - <br />main manifold with tees can be pre -.assembled and used to mark the beginning and end of <br />WASTEFLOW lines. <br />h) For particularly tough soil conditions moisten the soil the day before opening trenches or <br />installing WASTEFLOW. Remember it is much easier to install the system in moist soil. The soil <br />should be moist but still should allow the proper operation of the installation equipment and not <br />cause smearing in the trenches. The soil surface should be dry so that the installation equipment <br />maintains traction. <br />i) Mark the four comers of the field. The top two comers should be at the same elevation and the <br />bottom two comers should be at a lower elevation. In freezing conditions the bottom dripline <br />must be higher than the supply and return line elevation at the dosing tank. <br />j) Install a watertight dosing tank. In freezing conditions the dosing tank should be at the lowest <br />elevation of the entire system. Install a watertight riser on the dosing tank if necessary. <br />k) Determine the proper size for the supply and return manifolds. See Worksheet line (L). <br />1) Install the PVC supply line from the dosing tank, up hill through one lower and one upper corner <br />stake of the dispersal field. Please refer to your State guidelines for depth of burial. <br />m) Paint a line between the two remaining corner stakes. <br />16 <br />Geotlow Design and Installation Manual <br />