Laserfiche WebLink
2.0 Design and Installation <br /> 2.16 SIZING CHARTS: <br /> TABLE 2: APPLICATION RATES BASED ON PERCOLATION <br /> Percolation Application Percolation Application Percolation Application <br /> Rate Rate Rate Rate Rate Rate <br /> (mpi) (gpd/ftz) (mpi) (gpd/ftz) (mpi) (gpd/ftz) <br /> <1 Req. LAMP 31 0.511 61 0.197 <br /> 1 1.2 32 0.5 62 0.194 <br /> 2 1.2 33 0.489 63 0.19 <br /> 3 1.2 34 0.478 64 0.187 <br /> 4 1.2 35 0.467 65 0.184 <br /> 5 1.2 36 0.456 66 0.18 <br /> 6 0.8 37 0.445 67 0.177 <br /> 7 0.8 38 0.434 68 0.174 <br /> 8 0.8 39 0.422 69 0.17 <br /> 9 0.8 40 0.411 70 0.167 <br /> 10 0.8 41 0.4 71 0.164 <br /> 11 0.786 42 0.389 72 0.16 <br /> 12 0.771 43 0.78 73 0.157 <br /> 13 0.757 44 0.367 74 0.154 <br /> 14 0.743 45 0.367 75 0.15 <br /> 15 0.729 46 0.356 76 0.147 <br /> 16 0.714 47 0.345 77 0.144 <br /> 17 0.7 48 0.334 78 0.14 <br /> 18 0.686 49 0.323 79 0.137 <br /> 19 0.671 50 0.311 80 0.133 <br /> 20 0.657 51 0.3 81 0.13 <br /> 21 0.643 52 0.289 82 0.127 <br /> 22 0.629 53 0.278 83 0.123 <br /> 23 0.614 54 0.267 84 0.12 <br /> 24 0.6 55 0.256 85 0.117 <br /> 25 0.589 56 0.245 86 0.113 <br /> 26 0.578 57 0.234 87 0.11 <br /> 27 0.567 58 0.223 88 0.107 <br /> 28 0.556 59 0.212 89 0.103 <br /> 29 0.545 60 0.2 90 0.1 <br /> 30 0.533 >90- 120 0.1 <br /> 2022 California Design&Installation Manual Page 10 www.eljen.com <br />