My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SCHULTE
>
16900
>
2800 - Aboveground Petroleum Storage Program
>
PR0528139
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/13/2022 10:53:21 AM
Creation date
3/21/2022 2:47:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0528139
PE
2832
FACILITY_ID
FA0007697
FACILITY_NAME
SAFEWAY DISTRIBUTION CENTER
STREET_NUMBER
16900
Direction
W
STREET_NAME
SCHULTE
STREET_TYPE
RD
City
TRACY
Zip
95377
APN
20943001
CURRENT_STATUS
01
SITE_LOCATION
16900 W SCHULTE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
48
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A NJ O A Q U l N Environmental Health Department <br /> COUNTY— <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SAFEWAY DISTRIBUTION CENTER 1 16900 W SCHULTE RD,TRACY March 07, 2022 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 619 CFR 112.7(e), 112.8(c)(6) Failure to keep written records of procedures, inspections, and tests for at least three <br /> years. <br /> OBSERVATION: The facility failed to comply with the following requirements: <br /> The facility failed to maintain records of inspections and tests in accordance with written procedures that the <br /> certifying engineer developed for the facility, including integrity tests, signed by the appropriate supervisor or <br /> inspector.The formal inspection report on the three 12,000-gallon diesel tanks were not observed on site. <br /> REGULATION GUIDANCE: 112.7(e)Conduct inspections and tests required by this part in accordance with written <br /> procedures that you or the certifying engineer develop for the facility.You must keep these written procedures and a <br /> record of the inspections and tests, signed by the appropriate supervisor or inspector,with the SPCC Plan for a <br /> period of three years. Records of inspections and tests kept under usual and customary business practices will <br /> suffice for purposes of this paragraph. <br /> 112.8(c)(6)Test or inspect each aboveground container for integrity on a regular schedule and whenever you make <br /> material repairs.You must determine, in accordance with industry standards,the appropriate qualifications for <br /> personnel performing tests and inspections,the frequency and type of testing and inspections,which take into <br /> account container size, configuration, and design (such as containers that are: shop-built,field-erected, <br /> skid-mounted, elevated, equipped with a liner, double-walled, or partially buried). Examples of these integrity tests <br /> include, but are not limited to: visual inspection, hydrostatic testing, radiographic testing, ultrasonic testing, acoustic <br /> emissions testing, or other systems of non-destructive testing.You must keep comparison records, and you must <br /> also inspect the container's supports and foundations. In addition, you must frequently inspect the outside of the <br /> container for signs of deterioration, discharges, or accumulation of oil inside diked areas. Records of inspections <br /> and tests kept under usual and customary business practices satisfy the recordkeeping requirements of this <br /> paragraph. <br /> CORRECTIVE ACTION: Immediately begin maintaining all inspections and tests in accordance with the <br /> procedures outlined in the SPCC Plan and begin using forms provided by the SPCC plan. Keep written inspection <br /> procedures and records of inspections and testing signed by the appropriate supervisor/inspector for at least three <br /> years. Submit proof of correction to the EHD. <br /> This is a Class II violation. <br /> 620 CFR 112.7(f)(1) Failed to train personnel on all discharge prevention details listed in this section. <br /> OBSERVATION: It appears that the oil handling personnel were not adequately trained, as required. Facility failed to <br /> provide training to employees on the contents of the SPCC Plan.The training provided to employees does not cover <br /> specifics of the SPCC Plan. <br /> REGULATION GUIDANCE: (f)(1)At a minimum,train your oil-handling personnel in the operation and maintenance <br /> of equipment to prevent discharges; discharge procedure protocols; applicable pollution control laws, rules, and <br /> regulations; general facility operations; and,the contents of the facility SPCC Plan. <br /> CORRECTIVE ACTION: Immediately provide adequate training to all oil handling personnel and submit a copy of <br /> the training log and training content to the EHD. <br /> This is a repeat violation, Class II. <br /> FA0007697 PR0528139 SCO01 03/07/2022 <br /> EHD 28-01 Rev.12/06/2021 Page 6 of 10 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.