My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2300 - Underground Storage Tank Program
>
PR0517272
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/21/2022 9:18:32 AM
Creation date
3/28/2022 8:14:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0517272
PE
2361
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
151
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PEIIRP1200-12 <br /> 4.2.4 Preparation. The procedures in this sec- 4.2.7 Test Equipment. Test equipment shall <br /> tion are general in nature and reflect the suggested include: <br /> vacuum Ievels and hold times for testing tank 0 a vacuum-generating device that can be used in <br /> secondary containment areas. Consult tank manu- a Class I, Division 1 area capable of pulling 15 <br /> facturer and authority having jurisdiction (AHJ) inches of mercury(Hg)vacuum; <br /> guidelines before performing these tests as their <br /> requirements may differ. • an automatic vacuum shutoff valve or vacuum <br /> regulator(The shutoff valve can be set to close at <br /> Determine if there is liquid present in the intersti- a predetermined safe level, preventing the pos- <br /> tial space. If liquid is found, determine if the fluid <br /> is water or product, and remove it to the extent <br /> _. i <br /> practicable. <br /> The hydrostatic pressure from a high water table <br /> imposes inward pressure on the outer wall of a <br /> UST. Applying a vacuum to the interstitial space <br /> of the tank creates additional pressure on the outer Y <br /> 1 <br /> wall. These combined forces can damage the <br /> secondary tank wall when there is a large defined <br /> space between the primary and secondary tanks. <br /> Consequently, to prevent damage to the tank, it iss � s <br /> important to observe the water table and associated <br /> recommended vacuum levels when testing. ' .r . <br /> Vent the primary tank to atmosphere during the FIGURE 4-3. The vacuum gauge and control valve used <br /> test. for tank interstitial testing. <br /> In some installations, the tank interstitial space <br /> may be vented to minimize the buildup of conden- <br /> sation.In these cases, seal off any vent lines to the <br /> tank interstitial space prior to testing. <br /> Determine the volume of the tank. This informa- <br /> tion is available from facility records or the auto- Z. <br /> matic tank gauge (ATG) readout. <br /> 4.2.5 Steel Tanks. Determine if the interstitial <br /> space is a"tight wrap" design or a "110%contain- <br /> ment" design. Tanks with a 110% containment <br /> design should use the latest version of Steel Tank <br /> Institute's (STI) Recommended Practice ROI2, <br /> f <br /> Recommended Practice for Interstitial Tightness a <br /> Testing of Existing Underground Double Wall Steel <br /> Tanks for testing. <br /> For tight wrap tanks, use the test method in this <br /> section. <br /> f <br /> i <br /> 4.2.6 Fiberglass Tanks. Determine if the inter- <br /> stitial space is a "tight wrap" design or a "110% ' <br /> containment" design. Either type of fiberglass tank <br /> may use this test, or the latest version of Fiber- _ <br /> JdOV <br /> glass Tank & Pipe Institute's, Field Test Protocol y <br /> for Testing the Annular Space of Installed Under- FIGURE 4-4. The plumber's plug provides a leak-tight <br /> ground Fiberglass Double and Triple-wall Tanks connection to draw a vacuum on the tank interstitial <br /> with Dry Annular Space, FT&PI 4101107, space. <br /> Qpei.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.