My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2615
>
2300 - Underground Storage Tank Program
>
PR0521537
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2024 4:12:45 PM
Creation date
3/28/2022 8:14:31 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0521537
PE
2371
FACILITY_ID
FA0014623
FACILITY_NAME
WEST VALLEY AUTO SERVICE LLC
STREET_NUMBER
2615
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95304
APN
21229017
CURRENT_STATUS
01
SITE_LOCATION
2615 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Overfill Prevention Equipment Inspection Report <br /> Tank ID (one OPE per column) Regular Super Diesel <br /> Are both Went and tank riser piping secondarily X Yes X Yes X Yes ❑ Yes <br /> contained? ❑ No ❑ No ❑ No ❑ No <br /> OPE Model V1R WR VIR <br /> f What is the OPE response when activated? ❑ Shut off ❑ Shut oft ❑ Shut off ❑ Shut off <br /> (Check all that apply.) Flow Flow Flow Flow <br /> ❑Restricts ❑Restricts ❑Restricts ❑Restricts <br /> Flow Flow Flow Flow <br /> X Audible X Audible X Audible ❑ Audible <br /> Alarm Alarm ! Alarm Alarm <br /> X Visual X Visual X Visual ❑ Visual <br /> Alarm Alarm Alarm Alarm <br /> Are flow restrictors installed on vent piping that ElYes* ❑ Yes* ❑ Yes; 1:1Yes* <br /> may interfere with the OPE operation? X No X No ' X No ❑ No <br /> At what level in the tank is the OPE set to 98.25" 75" 75" <br /> activate? (inches from bottom of tank) <br /> What is the percent capacity of the tank at 90% 9ffo- 90% <br /> which the OPE activates? <br /> Is the OPE in proper operating condition to X Yes X Yes X Yes ❑ Yes <br /> respond when the stored substance reaches I ❑ No ❑ No ❑ No ❑ No <br /> the designated regulatory level? <br /> 7. SUMMARY OF TESTING RESULTS <br /> OPE Inspection Results XPasS Pass XPass El Pass <br /> ❑Fail ❑Fail ❑Fail ❑Fail <br /> 8. COMMENTS <br /> Describe all results marked"Fail'and each proposed remedy. <br /> VIR -Veader Root TLS350 external alarm & horn. <br /> Mark here if: <br /> ❑Flow restrictors interfere with overfill prevention and equipment repairs required. <br /> Additional copies of this page may be attached. <br /> Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) <br /> Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.