Laserfiche WebLink
Power Hydrodynamics <br /> Pump Test Report <br /> Plant Location: 9595 East Peltier Rd. Power Company: PG&E <br /> Motor Make: U.S. Pump Make: No Name Plate <br /> Hp: 30 Meter Number: 61 297 T <br /> Type: Turbine <br /> Serial Number: 3140534 <br /> Customer Mailing Address: Marc- arcs" % Voltage: 440 <br /> 611 Tahoe <br /> Lodi, CA 95242 Amps: 37 <br /> Test Date: 6/21/00 Tester Kevin Poth <br /> Run Number 1 <br /> Standing Water Level (Ft): 109.1 <br /> Recovered Water Level(Ft): <br /> Draw Down (Ft): 4.3 <br /> Pumping Water Level (Ft): 113.4 <br /> Discharge Pressure at Gauge(PSI): 35 <br /> Total Lift: 194.3 <br /> Power Hydrodynamics Flow Rate(GPM): 482 <br /> Customer Flow Rate(GPM): <br /> Well Yield: 112.1 <br /> Acre Feet per 24 Hr: 2.1 <br /> Cubic Feet per Second (CFS): 1.1 <br /> Horsepower Input to Motor: 31.42 <br /> Percent of Rated Motor Load: 94.1 <br /> Kilowatt Input to Motor. 23.44 <br /> Kilowatt Hours per Acre Foot: 264.1 <br /> Cost to Pump an Acre Foot: $31.70 <br /> Energy Cost($/Hours) 2.82 <br /> Base Cost per Kwh: $0.120 <br /> Overall Plant Efficiency(%): 75.24 <br /> All results are based on conditions during the time of the test. If these conditions vary from the normal <br /> operation of your pump, the results shown may not describe the pump's normal performance. <br /> Overall efficiency of this plant is considered to be very good assuming this run represents plant's normal <br /> operating condition. <br /> Oil on the surface of the water in the well may have affected the accuracy of the water level measurements. <br /> Standing water level based on 5 minutes recovery, well could still be recovering. <br /> This pump has an adequate test section. <br />