My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2022
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
255
>
2300 - Underground Storage Tank Program
>
PR0537549
>
COMPLIANCE INFO_2022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/17/2023 11:07:19 AM
Creation date
4/5/2022 9:46:12 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2022
RECORD_ID
PR0537549
PE
2351
FACILITY_ID
FA0021617
FACILITY_NAME
HARNEY LANE AM PM
STREET_NUMBER
255
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
062-580-40
CURRENT_STATUS
01
SITE_LOCATION
255 E Harney Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PERIODIC TEST TYPE 0 2:PREMIUM .Q <br /> STANDARD D -� <br /> LIQUID SENSOR SETUP <br /> TYP:2.0i3.OIN FIBERGLASS _ <br /> ANNUAL TEST FAIL 2.0IN DIA LEN: 285 FEET <br /> ALARM DISABLED <br /> 3.0IN UTA LEN: 0 FEET L 1 :kEG STP SMP-HYDRO <br /> PERIODIC TEST FAIL DW SUMP 2-1 <br /> ALARM DISABLEDCATEGORY : STP SUMP <br /> SHUTDOWN RATE: 3.0 GPH <br /> GROSS 'TEST FAIL LOW PRESSURE SHUTOFF:NO <br /> ALARM DISABLED LOW PRESSURE : 0 PSI L 2:REG FILL SMP-HYDRO <br /> T 2:UL PREMIUM DW SUMP 2-1 PIPING SUMP <br /> ANN TEST AVERAGING: OFF DISPENSE MODE: CATEGORY <br /> PER TEST AVERAGING: OFF STANDARD <br /> SENSOR: NON-VENTED L 3:PREM STP SMP-HYDRO <br /> TANK TEST NOTIFY: OFF PRESSURE OFFSET: O.OPSI DW SUMP 2-1 <br /> TNK TST SIPHON BREAK OFFCATEGORY : STP SUMP <br /> MECHANICAL BLENDER: NO <br /> DELIVERY DELAY 1 MIN L 4:PREM FILL SMF'-HYDRO <br /> PUMP THRESHOLD 10.00% DW SUMP 2-1 <br /> CATEGORY : PIPING SUMP <br /> r L S:DIESEL STP SMP-HYDRO <br /> DW SUMP 2-1 <br /> CATEGORY STP SUMP <br /> G 3:DIESEL L 6:DIESEL FILL SMP-HDRO <br /> DW SUMP 2-1 <br /> TYP:2.0i3.0IN FIBERGLASS CATEGOR`! : PIPING SUMP <br /> 2.OIN PIA LEN: 180 FEET <br /> LEAK TEST METHOD f <br /> 3.OIN UTA LEN: 0 FEET L 7:DISP 1-2 UDC-HYDRO <br /> TEST ON DATE ALL TANK DW SUMP 2-1 <br /> AUG 10. 2012 SHUTDOWN RATE: 3.0 GPH CATEGORY DISPENSER PAN <br /> TIME : DISABLED LOW PRESSURF- SHUTOFF:NO <br /> TEST RATE :0.20 GAL/HR LOW PRESSURE : 0 PSI <br /> DURATION 2 HOURS <br /> T 3:DIESEL No. It L 8:DISP 3-4 UDC-HYDRO <br /> TST EARLY STOP:DISABLED DISPENSE MOUE: € DW SUMP 2-1 <br /> STANDARD ! CATEGORY DISPENSER PAN <br /> LEAK TEST REPORT FORMAT SENSOR: NON-VENTED <br /> NORMAL PRESSURE OFFSET: O.OPSI <br /> MECHANICAL BLENDER: NO L 9:DISP 5-6 UDC-HYDRO <br /> DW SUMP 2-1 <br /> CATEGORY : DISPENSER VAN <br /> i, <br /> L1O:DISP 7-8 UDC-HYDRO <br /> DW SUMP 2-1 <br /> CATEGORY : DISPENSER PAN <br /> PRESSURE LINE LEAK SETUP <br /> L11 :DISP 9-10-UDC-HDRO <br /> LINE LEAK LOCKOUT SETUP DW SUMP 2-1 <br /> G 1 :REGULAR - - - - - - - - - - - - CATEGORY : DISPENSER PAN <br /> LOCKOUT SCHEDULE <br /> TYP:2.0:3.0IN FIBERGLASS DAILY <br /> 2.0IN DIA LEN: 310 FEET START TIME: DISABLED <br /> f <br /> STOP TIME DISABLED L12:DISP 11-12UDC-HYDRO <br /> 3.0IN DIA LEN: 0 FEET DW SUMP ?-1 <br /> CATEGORY: DISPENSER <br /> SHUTDOWN RATE: 3.0 GPH f PPHN <br /> LOW PRESSURE SHUTOFF:NO <br /> LOW PRESSURE 0 PSI <br /> T 1 :UJVLEADED R L13:DISP 13-14UDC-HYDRO <br /> + DW SUMP 2-1 <br /> DISPENSE MODE: k. CATEGORY DISPEfJSER PAN <br /> STANDARD <br /> SENSOR: NON-VENTED <br /> PRESSURE OFFSET: O.OPSI <br /> MECHANICAL BLENDER: NO <br />
The URL can be used to link to this page
Your browser does not support the video tag.